Macular Oxygen Saturation in Glaucoma Using Retinal Oximetry of Visible Light Optical Coherence Tomography: A Pilot Study

被引:0
|
作者
Wang, Jingyu [1 ]
Sadlak, Natalie [2 ]
Fiorello, Marissa G. [2 ]
Desai, Manishi [2 ]
Yi, Ji [1 ,3 ,4 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Ophthalmol, Baltimore, MD USA
[2] Boston Med Ctr, Dept Ophthalmol, Boston, MA USA
[3] Boston Univ, Boston Med Ctr, Sch Med, Dept Med, Boston, MA USA
[4] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
来源
关键词
visible light optical coherence tomography; retinal oximetry; glaucoma; GANGLION-CELL FUNCTION; NERVE-FIBER LAYER; OCT; THICKNESS; VESSELS; DAMAGE; ANGIOGRAPHY; METABOLISM;
D O I
10.1167/tvst.14.2.12
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: A cross-sectional pilot study to compare macular oxygen saturation (sO2) and associated clinical measurements between normal and glaucoma subjects and to evaluate whether macular sO2 can be a diagnostic metric for early-stage glaucoma. Methods: Forty-eight eyes of 35 subjects from three groups were included: normal subjects (16 eyes, 10 subjects), suspect/pre-perimetric glaucoma (GS/PPG) subjects (17 eyes, 12 subjects), and perimetric glaucoma (PG) subjects (15 eyes, 13 subjects). We performed retinal oximetry of visible light optical coherence tomography (VIS-OCT) in macular vessels, with 512 x 256 sampling points over a 5 x 5 mm2 area. Zeiss Cirrus OCT scans and a 24-2 visual field test (VFT) were conducted. Statistical analysis was conducted. Results: Significant differences were observed among the three groups for all VIS-OCT, Zeiss OCT, and VFT variables. As glaucoma severity increased, macular AsO2 (arterial sO2) and A-V sO2 (arteriovenous sO2 difference) decreased, whereas macular VsO2 (venous sO2) increased. Macular AsO2 and A-V sO2 were found to be statistically correlated with ganglion cell layer + inner plexiform layer (GCL+IPL) and circumpapillary retinal nerve fiber layer in all eyes, as well as in PG eyes. Within the PG group, a dominant correlation between AsO2 and ganglion cell layer+ inner plexiform layer was observed in the more damaged lower hemifield. Conclusions: Glaucoma subjects showed altered macular sO2, indicating reduced oxygen consumption. The sO2 measured by VIS-OCT could be a potential metric for early glaucoma diagnosis. Translational Relevance: This study shows macular sO2 measurements via VIS-OCT could bridge advanced imaging technology and clinical glaucoma detection.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Oxygen Saturation of Macular Vessels in Glaucoma Subjects Using Visible Light Optical Coherence Tomography
    Wang, Jingyu
    Song, Weiye
    Sadlak, Natalie
    Fiorello, Marissa Gabrielle
    Manishi, Desai
    Yi, Ji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [2] Visible-light optical coherence tomography for retinal oximetry
    Yi, Ji
    Wei, Qing
    Liu, Wenzhong
    Backman, Vadim
    Zhang, Hao F.
    OPTICS LETTERS, 2013, 38 (11) : 1796 - 1798
  • [3] Retinal capillary oximetry with visible light optical coherence tomography
    Pi, Shaohua
    Hormel, Tristan T.
    Wei, Xiang
    Cepurna, William
    Wang, Bingjie
    Morrison, John C.
    Jia, Yali
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2020, 117 (21) : 11658 - 11666
  • [4] Clinical retinal oximetry with visible-light optical coherence tomography
    Rubinoff, Ian
    Kuranov, Roman
    Wang, Yuanbo
    Ghassabi, Zeinab
    Wollstein, Gadi
    Tayebi, Behnam
    Ishikawa, Hiroshi
    Schuman, Joel
    Zhang, Hao
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [5] Retinal oximetry in humans using visible-light optical coherence tomography [Invited]
    Chen, Siyu
    Shu, Xiao
    Nesper, Peter L.
    Liu, Wenzhong
    Fawzi, Amani A.
    Zhang, Hao F.
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03): : 1415 - 1429
  • [6] A Baseline Study of Oxygen Saturation in Parafoveal Vessels Using Visible Light Optical Coherence Tomography
    Wang, Jingyu
    Song, Weiye
    Sadlak, Natalie
    Fiorello, Marissa G.
    Desai, Manishi
    Yi, Ji
    FRONTIERS IN MEDICINE, 2022, 9
  • [7] Measuring oxygen saturation in retinal and choroidal circulations in rats using visible light optical coherence tomography angiography
    Chen, Siyu
    Yi, Ji
    Zhang, Hao F.
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (08): : 2840 - 2853
  • [8] Automated spectroscopic retinal oximetry with visible-light optical coherence tomography
    Pi, Shaohua
    Camino, Acner
    Cepurna, William
    Wei, Xiang
    Zhang, Miao
    Huang, David
    Morrison, John
    Jia, Yali
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (05): : 2056 - 2067
  • [9] Adaptive spectroscopic visible-light optical coherence tomography for clinical retinal oximetry
    Rubinoff, Ian
    Kuranov, Roman V.
    Fang, Raymond
    Ghassabi, Zeinab
    Wang, Yuanbo
    Beckmann, Lisa
    Miller, David A.
    Wollstein, Gadi
    Ishikawa, Hiroshi
    Schuman, Joel S.
    Zhang, Hao F.
    COMMUNICATIONS MEDICINE, 2023, 3 (01):
  • [10] Adaptive spectroscopic visible-light optical coherence tomography for clinical retinal oximetry
    Ian Rubinoff
    Roman V. Kuranov
    Raymond Fang
    Zeinab Ghassabi
    Yuanbo Wang
    Lisa Beckmann
    David A. Miller
    Gadi Wollstein
    Hiroshi Ishikawa
    Joel S. Schuman
    Hao F. Zhang
    Communications Medicine, 3