Revision Rates for Aseptic Loosening in the Obese Patient: A Comparison Between Stemmed, Uncemented, and Unstemmed Tibial Total Knee Arthroplasty Components

被引:0
|
作者
van Duren, Bernard H. [1 ]
Firth, Amy M. [1 ]
Berber, Reshid [1 ]
Matar, Hosam E. [1 ]
James, Peter J. [1 ]
Bloch, Benjamin, V [1 ]
机构
[1] Nottingham Univ Hosp NHS Trust, Nottingham Elective Orthopaed Serv, Nottingham, England
来源
ARTHROPLASTY TODAY | 2025年 / 32卷
关键词
Total knee arthroplasty; Obesity; BMI; Cementless; Loosening; Revision; BMI; TKA;
D O I
10.1016/j.artd.2025.101621
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total knee arthroplasty (TKA) is an effective treatment option for high body mass index (BMI) patients achieving similar outcomes to nonobese patients. However, increased rates of aseptic loosening in patients with a high BMI have been reported. Component fixation is a concern when performing TKA in the obese patient. To address this concern in cemented TKA, extended tibial stems have been used. Uncemented implants that take advantage of biologic osseointegration have also been advocated. This retrospective study examined the use of and revision rates of extended cemented tibial stems and uncemented implants compared with conventional cemented implants in our high BMI patient population. Methods: We retrospectively reviewed a prospectively maintained database of 3239 primary Attune TKAs (Depuy, Warsaw, Indiana). All obese patients (BMI > 30 kg/m(2)) with > 30 months of follow-up were included in our analysis. Those who underwent cemented TKA using a tibial stem extension (Group 1) (n = 145) and those where cementless implants were used (Group 2) (n = 100) were compared to a control group (n = 1243) using a standard cemented implant. Primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Results: In total, there were 1512 knees that met the inclusion criteria. The mean follow-up was 6.8, 5.1, and 5.3 years for cemented, stemmed, and cementless groups, respectively. There were 37 all-cause revisions identified. Seven were for aseptic loosening (2 tibial, 1 femoral, and 4 involving both components); all of these were in the standard cemented implant group. There were no revisions in the stemmed or cementless implant groups. Survival analysis did not show any significant differences between groups for either all-cause revision or for aseptic loosening. Conclusions: This retrospective analysis showed that there were no revisions required for aseptic loosening when a cemented, stemmed, or uncemented implant was used in obese patients. These findings show that cementless and extended stem implants are a reasonable option in obese patients. (c) 2025 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Is cementing technique the cause of early aseptic loosening of the tibial component in total knee arthroplasty? A report of 22 failed tibial components
    Endres, Stefan
    Wilke, Axel
    ORTHOPEDIC REVIEWS, 2011, 3 (01) : 20 - 23
  • [22] A Comparison Between Unstemmed and Stemmed Constrained Condylar Knee Prostheses in Primary Total Knee Arthroplasty: A Propensity Score-Matched Analysis
    Zhao, En-Ze
    Zeng, Wei-Nan
    Ding, Zi-Chuan
    Liu, Zun-Han
    Luo, Zhen-Yu
    Zhou, Zong-Ke
    ORTHOPAEDIC SURGERY, 2022, 14 (02) : 246 - 253
  • [23] Clinical and radiological results of a stemmed medial pivot revision implant in aseptic total knee revision arthroplasty
    Berti, Mattia
    Vecchini, Eugenio
    Micheloni, Gian Mario
    Maluta, Tommaso
    Magnan, Bruno
    Ricci, Matteo
    KNEE, 2020, 27 (04): : 1190 - 1196
  • [24] Revision total knee arthroplasty with cemented components and uncemented intramedullary stems
    Shannon, BD
    Klassen, JF
    Rand, JA
    Berry, DJ
    Trousdale, RT
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 27 - 32
  • [25] Poor outcomes of revision total knee arthroplasty in patients with septic loosening compared to patients with aseptic loosening
    Baek, Ji-Hoon
    Lee, Su Chan
    Jin, Hosun
    Kim, Jin-Woo
    Ahn, Hye Sun
    Nam, Chang Hyun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [26] Poor outcomes of revision total knee arthroplasty in patients with septic loosening compared to patients with aseptic loosening
    Ji-Hoon Baek
    Su Chan Lee
    Hosun Jin
    Jin-Woo Kim
    Hye Sun Ahn
    Chang Hyun Nam
    Journal of Orthopaedic Surgery and Research, 16
  • [27] Classification of Bone Loss With Failed Stemmed Components in Revision Total Knee Arthroplasty
    Scuderi, Giles R.
    Weinberg, Maxwell
    JOURNAL OF ARTHROPLASTY, 2022, 37 (06): : S258 - S262
  • [28] In Total Knee Arthroplasty, Cementless and Hybrid Tibial Components Did Not Differ from Cemented Components for Revision-Free Survival and Had No Aseptic Loosening at 10 Years
    Reddy, Nithin C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2023, 105 (22):
  • [29] Tibial component fixation in total knee arthroplasty - A comparison of pegged and stemmed designs
    Bertin, Kim C.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (05): : 670 - 678
  • [30] Significant differences in rates of aseptic loosening between two variations of a popular total knee arthroplasty design
    Michael Brown
    Rohan Ramasubbu
    Mark Jenkinson
    James Doonan
    Mark Blyth
    Bryn Jones
    International Orthopaedics, 2021, 45 : 2859 - 2867