Fault Detection and Fault Location in a Grid-Connected Microgrid Using Optimized Deep Learning Neural Network

被引:0
|
作者
Karthick, R. [1 ]
Saravanan, R. [2 ]
Arulkumar, P. [3 ]
机构
[1] SNS Coll Technol, Dept Elect & Elect Engn, Coimbatore, Tamilnadu, India
[2] Balaji Inst Technol & Sci, Dept Elect & Elect Engn, Warangal, Telangana, India
[3] VSB Engn Coll, Dept Elect & Elect Engn, Karur, Tamil Nadu, India
关键词
data processing; data set; deep learning; fault detection; microgrid; microgrid infrastructure; STRATEGY;
D O I
10.1002/oca.3237
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The significant prevalence of distributed energy resources in microgrids due to their unique characteristics and activities creates protection issues. This paper introduces fault detection and its location in an MG. The aim of the investigation is to enhance the system's efficiency and dependability, and fault detection and prediction are employed. Data are gathered from the operational Microgrid (MG) infrastructure dataset, and the data are fed to the Newton Time-Extracting Wavelet Transform (NTEWT). It cleanses the data and enhances the input data's quality. After the preprocessed data are fed to the feature extraction by using Distorted Gaussian Matched Filtering (DGMF), it extracts the five statistical features from the voltage signal. The optimal features are fed to the Deep Attention Dilated Residual Convolutional Neural Network (DADRCNN), which predicts the faults in the microgrid. The Dung Beetle Optimization (DBO) is utilized to optimize the weight parameter of DADRCNN. The MATLAB platform is utilized to implement the proposed method. The proposed method is contrasted with various existing approaches like Graph Convolutional Network and Graph Fourier Transform (GCN-GFT), Feed-Forward Neural Network and Back-Propagation Algorithm (FFNN-BPA), and Discrete Wavelet Transform and Radial Basis Function Neural Network (DWT-RBFN). The existing method shows a fault detection rate of 91.12, 88.80, and 84.239, and the proposed technique illustrates a fault detection rate of 99.9640, which is higher than other existing approaches. The existing method shows a false alarm rate of 0.758, 1.028, and 1.564, and the proposed technique shows a false alarm rate of 0.2519, which is lower than other existing methods. The proposed approach exhibits a reduced false alarm rate and a greater fault detection rate, it is concluded.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Fault Classification and Location in Microgrid Using Artificial Neural Networks
    Kumar, Dharm Dev
    Alam, Mahamad Nabab
    12TH INTERNATIONAL CONFERENCE ON SMART GRID, ICSMARTGRID 2024, 2024, : 395 - 399
  • [42] Grid-connected equivalent modeling of DC microgrid based on optimized extreme learning machine
    Wu Z.
    Qi S.
    Shang M.
    Shen D.
    1600, Electric Power Automation Equipment Press (40): : 43 - 48
  • [43] An optimal deep belief with buffalo optimization algorithm for fault detection and power loss in grid-connected system
    Alam, Md. Mottahir
    Haque, Ahteshamul
    Hakami, Jabir
    Khan, Asif Irshad
    Pasha, Amjad Ali
    Kasim, Navin
    Islam, Saiful
    Khan, Mohammad Amir
    Zahmatkesh, Sasan
    Hajiaghaei-Keshteli, Mostafa
    Irshad, Kashif
    SOFT COMPUTING, 2024, 28 (03) : 2577 - 2591
  • [44] An optimal deep belief with buffalo optimization algorithm for fault detection and power loss in grid-connected system
    Md. Mottahir Alam
    Ahteshamul Haque
    Jabir Hakami
    Asif Irshad Khan
    Amjad Ali Pasha
    Navin Kasim
    Saiful Islam
    Mohammad Amir Khan
    Sasan Zahmatkesh
    Mostafa Hajiaghaei-Keshteli
    Kashif Irshad
    Soft Computing, 2024, 28 : 2577 - 2591
  • [45] Waveform Characteristic Analysis and Recognition of Short-circuit Fault in Grid-connected AC Microgrid
    Zhao, Ming
    Zheng, Xin
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 732 - 735
  • [46] Fault Detection and Diagnosis of Grid-Connected Power Inverters using PCA and current mean value
    Martins, J. F.
    Fernao Pires, V.
    Limas, Celson
    Pires, A. J.
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 5185 - 5190
  • [47] Shading fault detection in a grid-connected PV system using vertices principal component analysis
    Rouani, Lahcene
    Harkat, Mohamed Faouzi
    Kouadri, Abdelmalek
    Mekhilef, Saad
    RENEWABLE ENERGY, 2021, 164 : 1527 - 1539
  • [48] Automatic Fault identification in Grid Connected Photovoltaic System using Neural Network Controller
    Sureshkumar, R.
    Prabha, S. U.
    Arumugam, M. Senthil
    PROCEEDINGS OF 2019 INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND KNOWLEDGE ECONOMY (ICCIKE' 2019), 2019, : 78 - 80
  • [49] Switch Fault Diagnosis of Grid-Connected Inverter Using Symmetrical Components
    Mimouni, Amina
    Laribi, Souad
    Bizhani, Hamed
    Iwanski, Grzegorz
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (05) : 5258 - 5272
  • [50] Enhancing reliability and efficiency of grid-connected solid-state transformer through fault detection and classification using wavelet transform and artificial neural network
    Kamble, Saurabh
    Chaturvedi, Pradyumn
    Chen, Ching-Jan
    Borghate, V. B.
    ELECTRICAL ENGINEERING, 2024, 106 (03) : 2525 - 2535