Is Endovascular Arteriovenous Fistula a Feasible Alternative for Hemodialysis Patients?

被引:0
|
作者
Vergara-Perez, Hugo [1 ]
Laplaza, Raul Diaitz-Usetxi [2 ]
Alba, Alejandro Perez [1 ]
Remiro, Pablo Balino [3 ]
Peris, Asuncion Rius [1 ]
Segarra, M. Angeles Fenollosa [1 ]
Vasquez, Alejandro Tamayo [2 ]
Reque, Javier [1 ]
机构
[1] Hosp Gen Univ Castellon, Nephrol Dept, Castellon De La Plana, Spain
[2] Hosp Gen Univ Castellon, Radiol Dept, Castellon De La Plana, Spain
[3] Univ Jaume 1, Dept Hlth Sci, Castellon De La Plana, Spain
关键词
Hemodialysis; Endovascular arteriovenous fistula; Arteriovenous fistula; Vascular access; CREATION; ENDOAVF; MULTICENTER; MORTALITY; OUTCOMES; FAILURE; FOREARM; TRIAL; RATES;
D O I
10.1159/000541233
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: For hemodialysis (HD) patients, the selection of vascular access is a crucial factor that significantly affects morbidity and mortality. Historically, native arteriovenous fistulas (AVFs) have been established using surgical techniques. However, devices facilitating percutaneous endovascular arteriovenous fistula (endoAVF) formation have recently been introduced in clinical practice, showing promising initial evidence. The primary objectives were technical success, efficacy, and cannulation rates. The secondary objectives included primary and cumulative patency, safety, and the number of procedures required to maintain fistula patency. Methods: A prospective, single-center, single-arm study included all patients who underwent endoAVF creation using the WavelinQ (TM) EndoAVF System at a University Hospital between December 2021 and August 2023. Results: A total of 20 patients who underwent an endoAVF were included. Technical success was 100%. In total, 75% (15) of the endoAVFs met the criteria for physiological suitability. The cannulation rate was 66% (10/15) for endoAVFs that reached physiological suitability. At 6 months of follow-up, the primary and cumulative patency rates were 65% and 75%, respectively; at 12 months, these were 50% and 70%, respectively. Serious adverse events were not observed. The reintervention rate was 0.33 procedures/patient-year. Conclusion: Based on our experience, creating AVFs using the WavelinQ 4-F EndoAVF System is safe and effective, with high technical success rates and acceptable patency and reintervention rates.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [21] Comparison between Surgical and Endovascular Hemodialysis Arteriovenous Fistula Interventions and Associated Costs
    Arnold, Renee J. G.
    Han, Yun
    Balakrishnan, Rajesh
    Layton, Andrew
    Lok, Charmaine E.
    Glickman, Marc
    Rajan, Dheeraj K.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 29 (11) : 1558 - 1566
  • [22] THE UPPER ARM ARTERIOVENOUS-FISTULA - AN ALTERNATIVE FOR VASCULAR ACCESS IN HEMODIALYSIS
    GADE, J
    AABECH, J
    HANSEN, RI
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1995, 29 (02): : 121 - 124
  • [23] Relationship of Arteriovenous Fistula Thrombosis and Complete Blood Counting Parameters in Hemodialysis Patients With Arteriovenous Fistula
    Azboy, Davut
    Temizturk, Zeki
    TURKISH JOURNAL OF NEPHROLOGY, 2023, 32 (04): : 284 - 287
  • [24] Endovascular Arteriovenous Fistula Creation
    Tyagi, Ravi
    Karani, Kunal
    Ahmed, Osman
    Navuluri, Rakesh
    CONTEMPORARY DIAGNOSTIC RADIOLOGY, 2021, 44 (23)
  • [25] Duplex sonography of arteriovenous fistula in chronic hemodialysis patients
    Misevic, Tonci
    Brkljacic, Boris
    Zibar, Lada
    Jakic, Marko
    Kurbel, Sven
    Radic, Radivoje
    Misevic, Sanja
    COLLEGIUM ANTROPOLOGICUM, 2006, 30 (03) : 535 - 541
  • [26] Early Complications of Arteriovenous Fistula in patients on maintenance Hemodialysis
    Asif, Muhammad
    Siddique, Faiza
    Awais, Anum
    Siddique, Usman
    Pirzada, Abrar-Ul-Hassan
    Saeed, Rabia
    Alam, Humaira
    Ahmed, Ahsen Nazir
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (05): : 1032 - 1034
  • [27] Analysis of arteriovenous fistula failure in hemodialysis patients.
    Ding, Hong
    Gao, Di
    BIOMEDICAL RESEARCH-INDIA, 2016, 27 (02): : 396 - 400
  • [28] Correlation of mortality and location of arteriovenous fistula in hemodialysis patients
    Stolic, Radojica V.
    Trajkovic, Goran Z.
    Krstic, Nebojsa J.
    Stolic, Dragica Z.
    Subaric-Gorgieva, Gordana
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (01): : 26 - 33
  • [29] Complications of arteriovenous fistula with polytetraflouroethylen grafts in hemodialysis patients
    Demir, D.
    Ceviker, K.
    Aydin, M. S.
    Sahinalp, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2015, 18 (01) : 120 - 123
  • [30] Disparities in arteriovenous fistula placement in older hemodialysis patients
    Patibandla, Bhanu K.
    Narra, Akshita
    DeSilva, Ranil
    Chawla, Varun
    Vin, Yael
    Brown, Robert S.
    Goldfarb-Rumyantzev, Alexander S.
    HEMODIALYSIS INTERNATIONAL, 2014, 18 (01) : 118 - 126