CHARGE ESTIMATION OF R1243ZF/R134A FOR A CONSTANT TEMPERATURE AND HUMIDITY AIR CONDITIONER

被引:0
|
作者
Wu, Xi [1 ]
Tang, Fengyi [1 ]
Ou, Zudi [1 ]
Xu, Shiming [1 ]
Zhu, Xiaojing [1 ]
机构
[1] Dalian Univ Technol, Sch Energy & Power Engn, Key Lab Ocean Energy Utilizat & Energy Conservat, Minist Educ, Dalian 116024, Peoples R China
基金
中国国家自然科学基金;
关键词
Refrigerant; Hydrofluoroolefin; HFO-1243zf; Air conditioner; Charge; REFRIGERANT; PERFORMANCE; REPLACEMENT; SYSTEM;
D O I
10.18462/iir.HFO2023.0019
中图分类号
O414.1 [热力学];
学科分类号
摘要
Currently, the constant temperature and humidity air conditioner usually takes R410A as the refrigerant. However, R410A has been scheduled to be phased out in future due to its large global warming potential (GWP) value. R1243zf (3,3,3-trifluoropropene) is one of the available new refrigerants for its favourable thermodynamic and transport properties, as well as the low climate change effect. R1243zf is flammable, and it has not been widely considered as a commercially viable single-component refrigerant. In this paper, R1243zf/R134a blend is proposed to be the low GWP refrigerant for an air conditioner. The mathematical simulation model of a constant temperature and humidity air conditioner was newly built, and then the theoretical refrigerating cycle and suitable refrigerant charge was estimated. It is found that the required refrigerant charge of R1243zf/R134a (0.5/0.5) is smaller (approximately 18% in reduction) than that of R410A, besides the coefficients of performance are elevated in range of 3.93% to 10.77%.
引用
收藏
页码:142 / 149
页数:8
相关论文
共 50 条
  • [41] Low GWP Fluids for Replacing R134a in an Air-Conditioning System
    Li, Houpei
    Peng, Jinqing
    6TH IIR CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR2021), 2021, : 350 - 357
  • [42] Performance evaluation of alternative refrigerants for R134a in automotive air conditioning system
    Zhang, Nuochen
    Dai, Yuande
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2022, 17 (01)
  • [43] Experimental energy evaluation of R516A and R513A as replacement of R134a in refrigeration and air conditioning modes
    Mendez-Mendez, D.
    Perez-Garcia, V.
    Morales-Fuentes, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 154 : 73 - 83
  • [44] Solar assisted R22 and R134a heat pump systems for low temperature applications
    AbouZiyan, HZ
    Ahmed, MF
    Metwally, MN
    AbdElHameed, HM
    IECEC 96 - PROCEEDINGS OF THE 31ST INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4, 1996, : 787 - 792
  • [45] PERFORMANCE OF R1234yf AND R513A AS ALTERNATIVES TO R134a IN AUTOMOTIVE AIR CONDITIONING SYSTEMS IN WINTER
    Meng, Zhaofeng
    Cui, Xiangna
    Liu, Yin
    Wang, Shun
    DU, Chenyang
    Hu, Rusheng
    THERMAL SCIENCE, 2023, 27 (3A): : 1937 - 1946
  • [46] Saturated pressure measurements of 3,3,3-trifluoroprop-1-ene (R1243zf) for reduced temperatures ranging from 0.62 to 0.98
    Brown, J. Steven
    Di Nicola, Giovanni
    Fedele, Laura
    Bobbo, Sergio
    Zilio, Claudio
    FLUID PHASE EQUILIBRIA, 2013, 351 : 48 - 52
  • [47] Molecular Simulation Studies on the Vapor-Liquid Equilibrium of CO2+3,3,3-Trifluoropropene (R1243zf) Binary Mixtures
    Zhao, Jingxin
    Hu, Peng
    Zhang, Nan
    JOURNAL OF PHYSICAL CHEMISTRY B, 2024, 128 (03): : 812 - 823
  • [48] Experimental assessments on R430A as an environment-friendly replacement to R134a in vehicle air conditioners
    J. D. Andrew Pon Abraham
    M. Mohanraj
    M. Selvakumar
    Arun K. Raj
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2021, 43
  • [49] Experimental assessments on R430A as an environment-friendly replacement to R134a in vehicle air conditioners
    Abraham, J. D. Andrew Pon
    Mohanraj, M.
    Selvakumar, M.
    Raj, Arun K.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2021, 43 (03)
  • [50] Experimental study on constant temperature and humidity air-conditioner with recovering condensing heat
    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    不详
    Hsi An Chiao Tung Ta Hsueh, 2008, 5 (524-527+550):