Development of a laser sweeping system for precise positioning of Thomson measurement in KSTAR

被引:0
|
作者
Lee, Jong-ha [1 ,2 ]
Kim, Ha Jin [1 ]
Park, Gheunhyung [1 ,2 ]
机构
[1] Korea Inst Fus Energy, Daejeon, South Korea
[2] Univ Sci & Technol, KFE Sch, Daejeon, South Korea
关键词
Thomson scattering diagnostic; Laser positioning; Alignment; KSTAR; Tokamak;
D O I
10.1016/j.fusengdes.2025.114993
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Thomson diagnostics are essential for diagnosing electron density (ne) and electron temperature (Te) profiles in most plasma machines. However, precise alignment of the laser path with the collection optics focus is crucial to obtain the Thomson signal. Misalignment can lead to inaccuracies in measuring the signal and may introduce errors in plasma parameters. Therefore, precise control of the laser beam position inside the vacuum vessel is necessary. Many researchers involved in Thomson diagnostics carefully adjust the laser beam path and position to ensure accurate measurements. The KSTAR Thomson system traditionally aligned the laser beam with the collection optics focus manually using LED backlighting. However, this alignment process is challenging and time-consuming due to radiation in the vacuum vessel. To address this issue, a laser sweeping system was recently installed to enhance alignment accuracy and minimize working time in the vacuum vessel. This system includes a step motor installed on the last laser guiding mirror, enabling remote adjustment of the laser beam position from the diagnostics room. The Rayleigh signal was measured while sweeping the laser in both the vertical and horizontal directions under a 40 mbar nitrogen gas condition. The obtained signal was analyzed using a three-pulse fitting method. The vertical and horizontal sweeping intervals were set to 20 steps. As a result, for vertical sweeping, both the core and edge regions showed peak signals around the +60 step region. For horizontal sweeping, the core region exhibited a peak at +60 steps, whereas for the edge region, the signal increased as the position moved below -60 steps. This indicates that the horizontal focal position of the edge lens is aligned more inward than initially expected. This study demonstrates that precise alignment can be achieved by horizontally and vertically sweeping the mirror from the laser injection side. And the purpose of laser sweeping in this study is to verify and correct slight misalignments that may occur after the baking process.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Precise measurement of laser power using an optomechanical system
    Agatsuma, Kazuhiro
    Friedrich, Daniel
    Ballmer, Stefan
    DeSalvo, Giulia
    Sakata, Shihori
    Nishida, Erina
    Kawamura, Seiji
    OPTICS EXPRESS, 2014, 22 (02): : 2014 - 2031
  • [22] Development of a YAG laser system for the edge Thomson scattering system in ITER
    Hatae, T.
    Yatsuka, E.
    Hayashi, T.
    Yoshida, H.
    Ono, T.
    Kusama, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [23] Laser Thomson scattering system for anisotropic electron temperature measurement in NUMBER
    Okamoto, A.
    Higuchi, S.
    Sato, K.
    Yamada, Y.
    Koike, M.
    Sugimoto, M.
    Fujita, T.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (10)
  • [24] Laser intensity measurement by Thomson scattering
    Gao, J
    APPLIED PHYSICS LETTERS, 2006, 88 (09)
  • [25] Development of FBG Interrogation System using Wavelength Sweeping of FDML Laser
    Yamaguchi, Tatsuva
    Shinoda, Yukitaka
    2016 IEEE SENSORS, 2016,
  • [26] Development of high-efficiency laser Thomson scattering measurement system for the investigation of EEDF in surface wave plasma
    Aramaki, M
    Kobayashi, J
    Kono, A
    Stamate, E
    Sugai, H
    THIN SOLID FILMS, 2006, 506 : 679 - 682
  • [27] Development of pellet injection system for KSTAR
    Park, Soo-Hwan
    Kim, Hong-Tack
    Vinyar, Igor
    Lee, Juhyoung
    Lukin, Alexander
    Kim, Kyungmin
    Park, Hyun-Ki
    Ahn, Hee-Jae
    Lee, Jonghwa
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 163 - 166
  • [28] Technology trends of precise satellite positioning and its application for precise measurement
    Sumio U.
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2011, 77 (04): : 358 - 361
  • [29] Development status of KSTAR ECH system
    Joung, M.
    Wang, S. J.
    Kim, S. G.
    Han, J. W.
    Lee, I. H.
    Kwak, J. G.
    23RD TOPICAL CONFERENCE ON RADIOFREQUENCY POWER IN PLASMAS, 2020, 2254
  • [30] Progress in Development of KSTAR ICRF System
    Hong, B.G.
    Bae, Y.D.
    Hwang, C.K.
    Jeong, S.U.
    Kwak, J.G.
    Yoon, J.S.
    IEEE Int Conf Plasma Sci, 1600, (383):