Bioelectrical Impedance Versus Air-Displacement Plethysmography for Body Fat Measurements in Subjects with Abdominal Obesity: A Comparative Study

被引:1
|
作者
Cretescu, Iuliana [1 ]
Horhat, Raluca [1 ,2 ]
Mocanu, Valeria [3 ,4 ]
Munteanu, Oana [1 ]
机构
[1] Victor Babes Univ Med & Pharm, Dept Funct Sci, Timisoara 300041, Romania
[2] Victor Babes Univ Med & Pharm, Ctr Modeling Biol Syst & Data Anal, Timisoara 300041, Romania
[3] Victor Babes Univ Med & Pharm, Dept Ophthalmol, Timisoara 300041, Romania
[4] Victor Babes Univ Med & Pharm, Ophthalmo ENT Tumor Sensory Res Ctr EYE ENT, Timisoara 300041, Romania
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 04期
关键词
body composition; bioelectrical impedance; air-displacement plethysmography; central obesity; X-RAY ABSORPTIOMETRY; MASS INDEX; ADIPOSITY; RELIABILITY;
D O I
10.3390/app15042056
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Obesity is a disorder with an increasing prevalence, associated with cardiovascular and metabolic pathologies. The amount and the distribution pattern of adipose tissue must be considered when managing this disease. Abdominal obesity carries a higher risk of developing obesity-related comorbidities. Body composition methods allow an objective diagnosis and follow-up in obese patients. Although bioelectrical impedance (BIA) is a practical, affordable, and widespread technique to assess body fat percentage (%BF), its accuracy has often been questioned. Therefore, the present study aimed to determine BIA's accuracy in subjects with abdominal obesity compared to air-displacement plethysmography (AP) as the reference method. Measurements with both body composition techniques were performed on 80 subjects (41 men and 39 women) with a large range of body mass indexes (BMIs). Abdominal obesity, diagnosed as a waist-to-height ratio (WHtR) above 0.5, was present in 28 of them. Agreement between methods was analyzed using t-tests, correlation, and Bland-Altman plots. Compared to AP, BIA underestimated %BF by 3.07 +/- 5.81% (CCC = 0.82) in the entire study group. The agreement was comparable in subjects with and without central obesity (2.97 +/- 6.21% and 3.26 +/- 5.1%, respectively). The changes in body shape geometry due to different adipose tissue distribution patterns only marginally affected BIA's determinations.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Comparison of Air Displacement Plethysmography and Multi-Frequency Bioelectrical Impedance Analysis for Body Composition Assessment
    Gordon, Benjamin T.
    Arikawa, Andrea Y.
    Gerkens, Kristin
    Gonzalez, Andriana
    Boyd, Sara
    Baskin, Amber
    Bednarzyk, Michele
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 907 - 907
  • [32] Comparative assessment of change in fat mass using dual X-ray absorptiometry and air-displacement plethysmography
    Warolin, J.
    Kantor, J.
    Whitaker, L. E.
    Choi, L.
    Acra, S.
    Buchowski, M. S.
    CLINICAL OBESITY, 2012, 2 (3-4) : 66 - 72
  • [33] Impact of Obstetrical Complications on Body Fat Percentage in Very Low Birthweight Infants Using Air-Displacement Plethysmography
    Law, Tameeka
    Newman, Roger B.
    Ebeling, Myla
    Korte, Jeffrey
    Katikaneni, Lakshmi
    REPRODUCTIVE SCIENCES, 2010, 17 (03) : 196A - 196A
  • [34] Whole body composition analysis by the BodPod air-displacement plethysmography method in children with phenylketonuria shows a higher body fat percentage
    Albersen, Monique
    Bonthuis, Marjolein
    de Roos, Nicole M.
    van den Hurk, Dorine A. M.
    Weber, Ems Carbasius
    Hendriks, Margriet M. W. B.
    de Sain-van der Velden, Monique G. M.
    de Koning, Tom J.
    Visser, Gepke
    JOURNAL OF INHERITED METABOLIC DISEASE, 2010, 33 : S283 - S288
  • [35] Comparing Bioelectrical Impedance Analysis, Air Displacement Plethysmography, and Dual-Energy X-Ray Absorptiometry for Body Composition in Pediatric Obesity
    Thajer, Alexandra
    Vasek, Martin
    Schneider, Sophie
    Kautzky-Willer, Alexandra
    Kainberger, Franz
    Durstberger, Sebastian
    Kranzl, Andreas
    Horsak, Brian
    Greber-Platzer, Susanne
    NUTRIENTS, 2025, 17 (06)
  • [36] Accuracy of anthropometry-based equations versus air-displacement plethysmography for the estimation of fat mass in rural Gambian infants
    Kimes, O. L.
    Doel, A. M.
    Naumenko, D. J.
    Washabaugh, J. R.
    Moore, S. E.
    Bernstein, R. M.
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 2021, 33
  • [37] Body composition measurements determined by air displacement plethysmography and eight-polar bioelectrical impedance analysis are equivalent in African American college students
    So, Wi-Young
    Swearingin, Brenda
    Crooms, Brandon
    Lee, Rami
    Choi, Yunjung
    Dail, Teresa K.
    Melton, Deana
    Fuller, Tiffany M.
    Ha, Chang-Ho
    HEALTHMED, 2012, 6 (06): : 1896 - 1899
  • [38] COMPARISON OF BODY FAT ESTIMATION USING SKIN FOLD THICKNESS MEASUREMENT AND SIMULTANEOUS AIR-DISPLACEMENT PLETHYSMOGRAPHY AT 8 WEEKS
    Liu, N. Hou
    Hourihane, J. O.
    Kenny, L.
    Kiely, M.
    Irvine, A. D.
    Murray, D. M.
    PEDIATRIC RESEARCH, 2010, 68 : 208 - 208
  • [39] An investigation into the effect of body mass index on the agreement between whole-body fat mass determined by MRI and air-displacement plethysmography
    Weedall, Andrew D.
    Wilson, Adrian J.
    Wayte, Sarah C.
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1103):
  • [40] VALIDITY AND RELIABILITY OF BIOELECTRICAL IMPEDANCE ANALYSIS TO ESTIMATE BODY FAT COMPARED TO AIR DISPLACEMENT PLETHYSMOGRAPHY AND DUAL-ENERGY X-RAY ABSORPTIOMETRY
    Conlon, C.
    Ingram, M.
    Walsh, D.
    von Hurst, P.
    Kruger, R.
    Stonehouse, W.
    ANNALS OF NUTRITION AND METABOLISM, 2013, 63 : 1478 - 1478