Bioelectrical Impedance Versus Air-Displacement Plethysmography for Body Fat Measurements in Subjects with Abdominal Obesity: A Comparative Study

被引:1
|
作者
Cretescu, Iuliana [1 ]
Horhat, Raluca [1 ,2 ]
Mocanu, Valeria [3 ,4 ]
Munteanu, Oana [1 ]
机构
[1] Victor Babes Univ Med & Pharm, Dept Funct Sci, Timisoara 300041, Romania
[2] Victor Babes Univ Med & Pharm, Ctr Modeling Biol Syst & Data Anal, Timisoara 300041, Romania
[3] Victor Babes Univ Med & Pharm, Dept Ophthalmol, Timisoara 300041, Romania
[4] Victor Babes Univ Med & Pharm, Ophthalmo ENT Tumor Sensory Res Ctr EYE ENT, Timisoara 300041, Romania
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 04期
关键词
body composition; bioelectrical impedance; air-displacement plethysmography; central obesity; X-RAY ABSORPTIOMETRY; MASS INDEX; ADIPOSITY; RELIABILITY;
D O I
10.3390/app15042056
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Obesity is a disorder with an increasing prevalence, associated with cardiovascular and metabolic pathologies. The amount and the distribution pattern of adipose tissue must be considered when managing this disease. Abdominal obesity carries a higher risk of developing obesity-related comorbidities. Body composition methods allow an objective diagnosis and follow-up in obese patients. Although bioelectrical impedance (BIA) is a practical, affordable, and widespread technique to assess body fat percentage (%BF), its accuracy has often been questioned. Therefore, the present study aimed to determine BIA's accuracy in subjects with abdominal obesity compared to air-displacement plethysmography (AP) as the reference method. Measurements with both body composition techniques were performed on 80 subjects (41 men and 39 women) with a large range of body mass indexes (BMIs). Abdominal obesity, diagnosed as a waist-to-height ratio (WHtR) above 0.5, was present in 28 of them. Agreement between methods was analyzed using t-tests, correlation, and Bland-Altman plots. Compared to AP, BIA underestimated %BF by 3.07 +/- 5.81% (CCC = 0.82) in the entire study group. The agreement was comparable in subjects with and without central obesity (2.97 +/- 6.21% and 3.26 +/- 5.1%, respectively). The changes in body shape geometry due to different adipose tissue distribution patterns only marginally affected BIA's determinations.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Validation of air-displacement plethysmography to measure body fat
    Garrow, JS
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2003, 77 (05): : 1338 - 1339
  • [2] Validation of air-displacement plethysmography for estimation of body fat mass in healthy elderly subjects
    A. Bosy-Westphal
    M. Mast
    C. Eichhorn
    C. Becker
    D. Kutzner
    M. Heller
    Manfred J. Müller
    European Journal of Nutrition, 2003, 42 : 207 - 216
  • [3] Validation of air-displacement plethysmography for estimation of body fat mass in healthy elderly subjects
    Bosy-Westhal, A
    Mast, M
    Eichhorn, C
    Becker, C
    Kutzner, D
    Heller, M
    Müller, MJ
    EUROPEAN JOURNAL OF NUTRITION, 2003, 42 (04) : 207 - 216
  • [4] Calibration of bioelectrical impedance analysis for body composition assessment in Ethiopian infants using air-displacement plethysmography
    Wibaek, R.
    Kaestel, P.
    Skov, S. R.
    Christensen, D. L.
    Girma, T.
    Wells, J. C. K.
    Friis, H.
    Andersen, G. S.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2015, 69 (10) : 1099 - 1104
  • [5] Calibration of bioelectrical impedance analysis for body composition assessment in Ethiopian infants using air-displacement plethysmography
    R Wibæk
    P Kæstel
    S R Skov
    D L Christensen
    T Girma
    J C K Wells
    H Friis
    G S Andersen
    European Journal of Clinical Nutrition, 2015, 69 : 1099 - 1104
  • [6] Body Fat Measurements in Elite Adolescent Volleyball Players: Correlation between Skinfold Thickness, Bioelectrical Impedance Analysis, Air-displacement Plethysmography, and Body Mass Index Percentiles
    Portal, Shawn
    Rabinowitz, Jonathan
    Adler-Portal, Dana
    Burstein, Ruty Pilz
    Lahav, Yair
    Meckel, Yoav
    Nemet, Dan
    Eliakim, Alon
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2010, 23 (04): : 395 - 400
  • [7] Monitoring body fat in the elderly: application of air-displacement plethysmography
    Fields, DA
    Hunter, GR
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2004, 7 (01): : 11 - 14
  • [8] Comparison of air-displacement plethysmography with hydrostatic weighing and bioelectrical impedance analysis for the assessment of body composition in healthy adults
    Biaggi, RR
    Vollman, MW
    Nies, MA
    Brener, CE
    Flakoll, PJ
    Levenhagen, DK
    Sun, M
    Karabulut, Z
    Chen, KY
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1999, 69 (05): : 898 - 903
  • [9] Hand-to-foot bioelectrical impedance analysis to measure fat mass in healthy children: A comparison with air-displacement plethysmography
    Foucart, Lisa
    De Decker, Annelies
    Sioen, Isabelle
    De Henauw, Stefaan
    Michels, Nathalie
    NUTRITION & DIETETICS, 2017, 74 (05) : 516 - 520
  • [10] Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults
    Macias, Nayeli
    Aleman-Mateo, Heliodoro
    Esparza-Romero, Julian
    Valencia, Mauro E.
    NUTRITION JOURNAL, 2007, 6 (1)