Inter-rater reliability of hand motor function assessment in Parkinson's disease: Impact of clinician training

被引:1
|
作者
Kenny, Lorna [1 ]
Azizi, Zahra [1 ]
Moore, Kevin [1 ]
Alcock, Megan [2 ]
Heywood, Sarah [2 ]
Jonsson, Agnes [2 ]
McGrath, Keith [2 ]
Foley, Mary J. [3 ]
Sweeney, Brian [4 ]
O'Sullivan, Sean [4 ]
Barton, John [5 ]
Tedesco, Salvatore [5 ]
Sica, Marco [5 ]
Crowe, Colum [5 ]
Timmons, Suzanne [1 ]
机构
[1] Univ Coll Cork, Ctr Gerontol & Rehabil, Sch Med, Cork T12 XH60, Ireland
[2] Mercy Univ Hosp, Cork T12 WE28, Ireland
[3] Cork Stroke Support Ctr, Cork T12 AKA4, Ireland
[4] Bon Secours Hosp, Neurol Dept, Cork T12 DV56, Ireland
[5] Univ Coll Cork, Tyndall Natl Inst, Cork T12 AV22, Ireland
关键词
Parkinson's disease; Assessment; Inter-rater reliability; Variability; MDS-UPDRS; RATING-SCALE;
D O I
10.1016/j.prdoa.2024.100278
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Medication adjustments in Parkinson's disease (PD) are driven by patient subjective report and clinicians' rating of motor feature severity (such as bradykinesia and tremor). Objective: As patients may be seen by different clinicians at different visits, this study aims to determine the interrater reliability of upper limb motor function assessment among clinicians treating people with PD (PwPD). Methods: PwPD performed six standardised hand movements from the Movement Disorder Society's Unified Parkinson's Disease Rating Scale (MDS-UPDRS), while two cameras simultaneously recorded. Eight clinicians independently rated tremor and bradykinesia severity using a visual analogue scale. We compared intraclass correlation coefficient (ICC) before and after a training/calibration session where high-variance participant videos were reviewed and MDS-UPDRS instructions discussed. Results: In the first round, poor agreement was observed for most hand movements, with best agreement for resting tremor (ICC 0.66 bilaterally; right hand 95 % CI 0.50-0.82; left hand: 0.50-0.81). Postural tremor (left hand) had poor agreement (ICC 0.14; 95% CI 0.04-0.33), as did wrist pronation-supination (right hand ICC 0.34; 95 % CI 0.19-0.56). In post-training rating exercises, agreements improved, especially for the right hand. Best agreement was observed for hand open-close ratings in the left hand (ICC 0.82, 95 % CI 0.64-0.94) and resting tremor in the right hand (ICC 0.92, 95 % CI 0.83-0.98). Discrimination between right and left hand features by raters also improved, except in resting tremor (disimprovement) and wrist pronation-supination (no change). Conclusions: Clinicians vary in rating video-recorded PD upper limb motor features, especially bradykinesia, but this can be improved somewhat with training.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Inter-rater reliability of a bronchiolitis severity assessment tool
    Walsh, P
    Gonzales, A
    Sattar, A
    Artman, B
    ANNALS OF EMERGENCY MEDICINE, 2005, 46 (03) : S91 - S91
  • [32] AN ASSESSMENT OF AN EVALUATION INSTRUMENT FOR INCREASING INTER-RATER RELIABILITY
    STANGEL, I
    CRANTON, PF
    JOURNAL OF DENTAL RESEARCH, 1984, 63 : 181 - 181
  • [33] Improvement of inter-rater reliability of PANSS items and subscales by a standardized rater training
    Muller, MJ
    Wetzel, H
    ACTA PSYCHIATRICA SCANDINAVICA, 1998, 98 (02) : 135 - 139
  • [34] Grant Peer Review: Improving Inter-Rater Reliability with Training
    Sattler, David N.
    McKnight, Patrick E.
    Naney, Linda
    Mathis, Randy
    PLOS ONE, 2015, 10 (06):
  • [35] Arthritis hand function test: Inter-rater reliability among self-trained raters
    Backman, C
    Mackie, H
    ARTHRITIS CARE AND RESEARCH, 1995, 8 (01): : 10 - 15
  • [36] Intra- and inter-rater reliability of the Sollerman hand function test in patients with chronic stroke
    Brogardh, Christina
    Persson, Ann L.
    Sjolund, Bengt H.
    DISABILITY AND REHABILITATION, 2007, 29 (02) : 145 - 154
  • [37] The inter-rater reliability of the Japanese version of the Inventory of Depressive Symptomatology, Clinician version
    Yamamoto, Nobutomo
    Kawakami, Sachiko
    Sato, Koichi
    Takimura, Tsuyoshi
    Inagaki, Ataru
    Inada, Toshiya
    HUMAN PSYCHOPHARMACOLOGY-CLINICAL AND EXPERIMENTAL, 2011, 26 (03) : 267 - 269
  • [38] Clinical assessment methods for scapular positioning and function. An inter-rater reliability study
    Larsen, Camilla Marie
    Sogaard, Karen
    Eshoj, Henrik
    Ingwersen, Kim
    Juul-Kristensen, Birgit
    PHYSIOTHERAPY THEORY AND PRACTICE, 2020, 36 (12) : 1399 - 1420
  • [39] Inter-rater reliability for noninvasive measurement of cardiac function in children
    Stewart, Gail M.
    Nguyen, H. Bryant
    Kim, Tommy Y.
    Jauregui, Joshua
    Hayes, Sean R.
    Corbett, Stephen
    PEDIATRIC EMERGENCY CARE, 2008, 24 (07) : 433 - 437
  • [40] Inter-rater reliability of structural imaging assessment with visual rating scales in patients with Alzheimer's disease
    Colak, B.
    Er, O.
    Kokurcan, A.
    Altunoz, U.
    Ozel-Kizil, E. T.
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2013, 23 : S543 - S544