Raman Spectroscopy Combined with Partial Least Squares for Quantitative Analysis of Two Kinds of Microplastics in Water Samples

被引:0
|
作者
Ding, Jian-Ming [1 ,2 ]
Wang, Xin [1 ]
Zhang, Rong-Ling [1 ]
Zhou, Li-Yuan [1 ]
Zhang, Tian-Long [1 ]
Tang, Hong-Sheng [1 ]
Li, Hua [3 ]
机构
[1] Northwest Univ, Coll Chem & Mat Sci, Key Lab Synthet & Nat Funct Mol Chem, Minist Educ, Xian 710127, Peoples R China
[2] Inst Hyg Ordnance Ind, Xian 710065, Peoples R China
[3] Xian Shiyou Univ, Coll Chem & Chem Engn, Xian 710065, Peoples R China
基金
中国国家自然科学基金;
关键词
Microplastics; Partial least squares; Raman spectroscopy; Chemometrics; FEATURE-SELECTION; PARTICLES; PLS;
D O I
10.19756/j.issn.0253-3820.241260
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microplastics (MPs) are emerging contaminants in aquatic environments characterized by their polar structure, small particle size (Typically less than 5 mm), large surface area, good stability, and resistance to biodegradation. They pose adverse effects on the normal physiological activities of aquatic organisms and can accumulate in biota, including humans. Therefore, there is an urgent need for rapid and accurate quantitative analysis of MPs in water environments. In this study, Raman spectroscopy combined with partial least squares (PLS) was employed for rapid and accurate quantitative analysis of polyethylene (PE) and polystyrene (PS) MPs in real water samples. Initially, 33 simulated water samples containing different concentrations of MPs were prepared, and their Raman spectra were collected. Six spectral preprocessing methods (Normalization, multiplicative scatter correction, standard normal variate transformation, first derivative, second derivative, and wavelet transform) were investigated for their impact on the predictive performance of PLS calibration models. Subsequently, three variable selection methods including synergy interval partial least squares (SiPLS), variable importance in projection (VIP) and mutual information (MI) were employed to optimize the input variables of the PLS calibration model. The predictive capability of the PLS calibration model was evaluated and validated using leave-one-out cross- validation. Under the optimal conditions of spectral preprocessing, variable selection, input variables and latent variables, the wavelet transform-partial least squares (WT-PLS) calibration model based on distilled water was established, and the contents of PE and PS in real water samples were predicted with prediction correlation coefficients (R2p) of 0.9540 and 0.8472 for PE and PS, respectively, and prediction errors (Errorp) of 0.0690 and 0.1126, respectively. Furthermore, a mixed sample MI-PLS calibration model was developed, demonstrating the best predictive performance in real water samples (With R 2 p values of 0.9776 and 0.9755 for PE and PS, respectively, and Errorp values of 0.0360 and 0.0392, respectively). This method provided a novel approach and new methodology for quantitative analysis of MPs and other organic pollutants in real water samples.
引用
收藏
页码:1581 / 1590
页数:10
相关论文
共 50 条
  • [41] Determination of florfenicol by Raman spectroscopy with principal component analysis (PCA) and partial least squares regression (PLSR)
    Ali, Zain
    Nawaz, Haq
    Majeed, Muhammad Irfan
    Rashid, Nosheen
    Mohsin, Mashkoor
    Raza, Ali
    Shakeel, Muhammad
    Ali, Muhammad Zeeshan
    Sabir, Amina
    Shahbaz, Muhammad
    Ehsan, Usama
    ul Hasan, Hafiz Mahmood
    ANALYTICAL LETTERS, 2024, 57 (01) : 30 - 40
  • [42] Quantitative Analysis of NaCl, NaOH, and β-phenylethylamine in Water using Ultraviolet Spectroscopy coupled with Partial Least Squares and Net Analyte Preprocessing
    Tang, Xiaojun
    Tong, Angxin
    Zhang, Feng
    Wang, Bin
    SAINS MALAYSIANA, 2020, 49 (08): : 1773 - 1785
  • [43] Raman spectroscopy for clinical-level detection of heparin in serum by partial least-squares analysis
    Monfared, Ali Momenpour T.
    Tiwari, Vidhu S.
    Tripathi, Markandey M.
    Anis, Hanan
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (02)
  • [44] Raman spectroscopy and partial least squares analysis in discrimination of peripheral cells affected by Huntington's disease
    Muratore, M.
    ANALYTICA CHIMICA ACTA, 2013, 793 : 1 - 10
  • [45] Determination of ethyl glucuronide (EtG) in blood samples using partial least squares discriminant analysis applied to surface-enhanced Raman spectroscopy
    Acikgoz, Gunes
    Hamamci, Berna
    VIBRATIONAL SPECTROSCOPY, 2020, 106
  • [46] Quantitative Determination of the Components in Corn and Tobacco Samples by Using Near-Infrared Spectroscopy and Multiblock Partial Least Squares
    Jing, Ming
    Cai, Wensheng
    Shao, Xueguang
    ANALYTICAL LETTERS, 2010, 43 (12) : 1910 - 1921
  • [47] Artificial neural networks (ANNs) and partial least squares (PLS) regression in the quantitative analysis of cocrystal formulations by Raman and ATR-FTIR spectroscopy
    Barmpalexis, P.
    Karagianni, A.
    Nikolakakis, I.
    Kachrimanis, K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 158 : 214 - 224
  • [48] QCL spectroscopy combined with the least squares method for substance analysis
    Samsonov, D. A.
    Tabalina, A. S.
    Fufurin, I. L.
    9TH RUSSIAN NATIONAL CONFERENCE ON IRREVERSIBLE PROCESSES IN NATURE AND TECHNICS (9RNC-IPNT), 2017, 918
  • [49] Application of partial least squares support vector machines (PLS-SVM) in spectroscopy quantitative analysis
    Lv, Jianfeng
    Dai, Liankui
    WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 5228 - +
  • [50] Near Infrared Spectroscopy Quantitative Analysis Model Based on Incremental Neural Network with Partial Least Squares
    Cao Hui
    Li Da-hang
    Liu Ling
    Zhou Yan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (10) : 2799 - 2803