The evaluation of asymmetrically aging effect on silicon rubber insulators flashover voltage

被引:0
|
作者
Seyyedbarzegar, Seyyedmeysam [1 ]
机构
[1] Shahrood Univ Technol, Fac Elect Engn, Shahrood, Iran
关键词
Silicon rubber insulator; Asymmetrically aging; Pollution; Flashover voltage; LEAKAGE CURRENT;
D O I
10.1108/WJE-09-2024-0535
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
PurposeThis study aims to examine the effect of asymmetric aging (120 and 270 degrees) and symmetrical aging on the performance of silicone rubber insulators. The effects of different aged surfaces, pollution levels and humidity on flashover voltage (FV) have been experimentally investigated. Based on the laboratory results, a mathematical model has been presented to estimate the FV of insulators.Design/methodology/approachAccording to insulators constituent materials, polymer insulators are affected by environmental conditions, specifically by ultraviolet (UV) radiation. To investigate the effect of aging and environmental conditions on the insulator, two types of silicone rubber insulators were aged under UV radiation. Environmental conditions have been created by changing humidity in five levels and pollution in three levels. All tests have been performed on two virgins, two full aged and four asymmetric-aged insulators. Also, according to the effect of each parameter on the FV, a mathematical model has been presented for it.FindingsUV aging causes the destruction of the silicon rubber insulator. The occurrence of flashover is one of the consequences of insulation failure. The enlargement of the aged surface has a nonlinear relationship with the reduction of the FV. By considering the effect of the aged surface, the accuracy of FV modeling can be increased. The results obtained from the mathematical model have shown that the estimation of the FV in different environmental conditions has an error of less than 5%. However, the modeling error is more than 15% if the effect of the aged surface is not considered.Originality/valueIn this work, it is intended to investigate the effect of asymmetric aging on the FV of the insulator. The obtained results have shown that the asymmetric aging surface is an important factor in changing the harmonic components of the leakage current, condition monitoring indicators and FV.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] CALCULATION OF DC AND AC FLASHOVER VOLTAGE OF POLLUTED INSULATORS
    GUAN, ZC
    ZHANG, R
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1990, 25 (04): : 723 - 729
  • [32] Flashover Voltage of Outdoor Insulators in the Presence of Multiple Drybands
    Ramesh, M.
    Gorur, R. S.
    2019 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2019, : 401 - 404
  • [33] Effect of shed design on aging performance of silicone rubber insulators
    El-Hag, AH
    Jayaram, S
    Cherney, EA
    2002 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2002, : 363 - 366
  • [34] Evaluation of aging process of silicone rubber composite insulators with photothermal radiometry
    Jiang, Haitao
    Li, Bincheng
    Zhao, Binxing
    Sun, Qiming
    Gao, Chunming
    Chen, Lincong
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2018, 51 (42)
  • [35] Silicon Films Effect on High Voltage Insulators.
    Steinbach, Hans Horst
    Elektrotechnische Zeitschrift Ausgabe A, 1975, 96 (03): : 126 - 128
  • [36] Review on flashover characteristics and measures to improve flashover voltage of the ice-coated insulators
    Huang, Dao-Chun
    Hu, Yi
    Wan, Qi-Fa
    Liu, Yun-Peng
    Ruan, Jiang-Jun
    Yao, Tao
    Xu, Tao
    Gao, Song
    Dianwang Jishu/Power System Technology, 2010, 34 (05): : 46 - 54
  • [37] Effect of core diameter of cylindrical polymer insulators on contamination flashover voltage - part I
    Gautam, Basanta Kumar
    Matsumura, Shigeki
    Sakanishi, Kenji
    Matsuoka, Ryosuke
    Ito, Masatoshi
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2006, 1 (03) : 298 - 305
  • [38] Evaluation of Flashover Voltage Property of Snow Accreted Insulators for Overhead Transmission Lines, Part III-154 kV Full-scale Flashover Voltage Test of Snow Accreted Insulators
    Homma, Hiroya
    Yaji, Kohei
    Aso, Teruo
    Watanabe, Masato
    Sakata, Gaku
    Dernfalk, Andreas
    Gutman, Igor
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) : 2568 - 2575
  • [39] Improvement of contamination flashover voltage performance of cylindrical porcelain insulators
    Yamada, Kazuma
    Hayashi, Akio
    Saka, Chiharu
    Sakanishi, Kenji
    Matsuoka, Ryosuke
    CONFERENCE RECORD OF THE 2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 2008, : 69 - 72
  • [40] Computation of ac Wet Flashover Voltage of Ceramic and Composite Insulators
    Lan, L.
    Gorur, R. S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (05) : 1346 - 1352