Sensitive and Fast Simultaneous Voltammetric Determination of Dopamine and Uric Acid Using Simple Screen-Printed Carbon Electrode Without Pretreatment and Modification

被引:0
|
作者
Niaz, Abdul [1 ,2 ]
Arain, Muhammad Balal [1 ,3 ]
Soylak, Mustafa [1 ,4 ,5 ]
机构
[1] Erciyes Univ, Fac Sci, Dept Chem, Kayseri, Turkiye
[2] Univ Sci & Technol, Dept Chem, Bannu, Kpk, Pakistan
[3] Univ Karachi, Dept Chem, Karachi, Pakistan
[4] Erciyes Univ, Technol Res & Applicat Ctr ERU TAUM, Kayseri, Turkiye
[5] Turkish Acad Sci TUBA, Ankara, Turkiye
关键词
dopamine; lower electrolyte concentration; simultaneous determination; unmodified screen-printed carbon electrode; uric acid; urine sample; ASCORBIC-ACID; ELECTROCHEMICAL DETECTION; NANOTUBES; SENSORS;
D O I
10.1002/elan.12001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, commercially available, unmodified screen-printed carbon electrode (SPCE) was investigated for the simultaneous voltammetric determination of dopamine (D/A) and uric acid (U/A) in a medium of very low concentration of supporting electrolyte for the first time. The ordinary, simple SPCE from DropSens (DS-SPCE) was found to be able to separate the overlapping peaks of D/A and U/A with a wide peak potential separation of 300 mV in a medium of very low concentration (0.001 M) of NaH2PO4 as supporting electrolyte (buffer of low capacity) at pH 8.0. Medium of low concentration of electrolyte made it possible to expose the bare electrode surface for its high catalytic activity which resulted into a high peak current signals, particularly for D/A. The DS-SPCE showed excellent electrocatalytic performance than the other SPCE. The effect of electrolyte concentration and pH on the electrocatalytic behavior of electrode were thoroughly discussed. The DS-SPCE displayed a sensitive results in good linear ranges from 0.1-5 to 6-20 mu M for D/A and 0.5-41.5 mu M for U/A. The disposable electrode demonstrated better discrimination ability toward the detection of D/A and U/A over ascorbic acid and other potential interfering species. Moreover, the sensor presented sensitive and highly accurate results in human urine samples without preliminary treatment. The DS-SPCE sensor was found to be simple, efficient, fast, low cost, and greener than the other reported modified sensors, while providing better sensitivities to detect D/A and U/A simultaneously. Thus, the bare, unmodified DS-SPCE can be a convenient sensing device for the routine analysis of D/A and U/A, without requiring any complex pretreatment and modification steps of the electrode.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Simultaneous Voltammetric Determination of Ascorbic Acid, Dopamine and Uric Acid Using Polybromothymol Blue Film-Modified Glassy Carbon Electrode
    Xu, Xiongwei
    Lin, Qihuang
    Liu, Ailin
    Chen, Wei
    Weng, Xiuhua
    Wang, Changlian
    Lin, Xinhua
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (06) : 788 - 793
  • [42] Simultaneous determination of dopamine, ascorbic acid, and uric acid using carbon ionic liquid electrode
    Safavi, Afsaneh
    Maleki, Norouz
    Moradlou, Omran
    Tajabadi, Fariba
    ANALYTICAL BIOCHEMISTRY, 2006, 359 (02) : 224 - 229
  • [43] Carbon-nanotube Modified Screen-printed Electrode for the Simultaneous Determination of Nitrite and Uric Acid in Biological Fluids Using Batch-injection Amperometric Detection
    Caetano, Larissa P.
    Lima, Ana P.
    Tormin, Thiago F.
    Richter, Eduardo M.
    Espindola, Foued S.
    Botelho, Francoise V.
    Munoz, Rodrigo A. A.
    ELECTROANALYSIS, 2018, 30 (08) : 1862 - 1871
  • [44] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Nahid Shoaie
    Mehdi Forouzandeh
    Kobra Omidfar
    Microchimica Acta, 2018, 185
  • [45] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Shoaie, Nahid
    Forouzandeh, Mehdi
    Omidfar, Kobra
    MICROCHIMICA ACTA, 2018, 185 (04)
  • [46] Voltammetric behavior and trace determination of lead at a mercury-free screen-printed carbon electrode
    Honeychurch, KC
    Hart, JP
    Cowell, DC
    ELECTROANALYSIS, 2000, 12 (03) : 171 - 177
  • [47] Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode
    Honeychurch, KC
    Hawkins, DM
    Hart, JP
    Cowell, DC
    TALANTA, 2002, 57 (03) : 565 - 574
  • [48] Treated Screen Printed Electrodes Based on Electrochemically Reduced Graphene Nanoribbons for the Sensitive Voltammetric Determination of Dopamine in the Presence of Uric Acid
    Mohammadi, Somayeh
    Taher, Mohammad Ali
    Beitollahi, Hadi
    ELECTROANALYSIS, 2020, 32 (09) : 2036 - 2044
  • [49] Electrochemical Determination of Chlorogenic Acid in Nutraceuticals Using Voltammetric Sensors Based on Screen-Printed Carbon Electrode Modified with Graphene and Gold Nanoparticles
    Munteanu, Irina-Georgiana
    Apetrei, Constantin
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (16)
  • [50] Electrochemical determination of bentazone using simple screen-printed carbon electrodes
    Geto, Alemnew
    Noori, Jafar Safaa
    Mortensen, John
    Svendsen, Winnie E.
    Dimaki, Maria
    ENVIRONMENT INTERNATIONAL, 2019, 129 : 400 - 407