Diagnostic accuracy of two-dimensional shear wave elastography and point shear wave elastography in identifying different stages of liver fibrosis in patients with metabolic dysfunction-associated steatotic liver disease: A meta-analysis

被引:0
|
作者
Xu, Xiangyi [1 ]
Zhang, Yiqing [1 ]
Zhu, Qiwei [1 ]
Xie, Yuchen [1 ]
Zhou, Yuanyuan [1 ]
Dong, Bingtian [1 ]
Zhang, Chaoxue [1 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Ultrasound, Hefei, Anhui, Peoples R China
关键词
Two-dimensional shear wave elastography; 2-D SWE; point shear wave elastography; pSWE; metabolic dysfunction-associated steatotic liver disease; MASLD; liver fibrosis; GLOBAL EPIDEMIOLOGY; WFUMB GUIDELINES; CLINICAL-USE; RECOMMENDATIONS; PREVALENCE; OUTCOMES; BIOPSY;
D O I
10.17305/bb.2024.11577
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
To assess the diagnostic accuracy of two-dimensional shear wave elastography (2-D SWE) and point shear wave elastography (pSWE) in detecting liver fibrosis stages in patients with metabolic dysfunction-associated steatotic liver disease (MASLD), a comprehensive search was conducted across four databases up to February 9, 2024. A bivariate random-effects model was used to analyze the diagnostic accuracy of the methods. After screening, 13 studies involving pSWE included 1527 patients, while nine studies involving 2-D SWE included 1088 patients. The areas under the summary receiver operating characteristic (SROC) curves for diagnosing significant fibrosis (F >= 2), advanced fibrosis (F >= 3), and cirrhosis (F = 4) using pSWE and 2-D SWE were as follows: 0.84 (95% CI 0.80-0.87), 0.91 (95% CI 0.88-0.93), and 0.94 (95% CI 0.91-0.95) for pSWE; 0.83 (95% CI 0.79-0.86) 0.85 (95% CI 0.82-0.88), and 0.89 (95% CI 0.86-0.91) for 2-D SWE, respectively. The pooled sensitivity for pSWE and 2-D SWE for stages F >= 2, F >= 3, and F = 4 were 0.71 (95% CI 0.63-0.78), 0.81 (95% CI 0.72-0.88), and 0.81 (95% CI 0.63-0.91) for pSWE, and 0.77 (95% CI 0.68-0.84), 0.80 (95% CI 0.72-0.87), and 0.92 (95% CI 0.75-0.98) for 2-D SWE, respectively. The pooled specificity of pSWE and 2-D SWE for these stages were 0.83 (95% CI 0.76-0.88), 0.87 (95% Cl: 0.81-0.92), and 0.91 (95% CI 0.86-0.94) for pSWE, and 0.76 (95% CI 0.66-0.84), 0.76 (95% CI 0.69-0.82), and 0.83 (95% CI 0.78-0.85) for 2-D SWE, respectively. In conclusion, both 2-D SWE and pSWE demonstrated high diagnostic performance in identifying various stages of liver fibrosis in MASLD patients.
引用
收藏
页数:32
相关论文
共 50 条
  • [41] Diagnostic Performance of Shear Wave Elastography in Patients With Autoimmune Liver Disease
    Li, Changtian
    Dhyani, Manish
    Bhan, Atul K.
    Grajo, Joseph R.
    Pratt, Daniel S.
    Gee, Michael S.
    Samir, Anthony E.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (01) : 103 - 111
  • [42] Two-dimensional ultrasound shear wave elastography for identifying and staging liver fibrosis in pediatric patients with known or suspected liver disease: a clinical effectiveness study
    Alhashmi, Ghufran H.
    Gupta, Anita
    Trout, Andrew T.
    Dillman, Jonathan R.
    PEDIATRIC RADIOLOGY, 2020, 50 (09) : 1255 - 1262
  • [43] Two-dimensional ultrasound shear wave elastography for identifying and staging liver fibrosis in pediatric patients with known or suspected liver disease: a clinical effectiveness study
    Ghufran H. Alhashmi
    Anita Gupta
    Andrew T. Trout
    Jonathan R. Dillman
    Pediatric Radiology, 2020, 50 : 1255 - 1262
  • [44] The utility of two-dimensional shear wave elastography and texture analysis for monitoring liver fibrosis in rat model
    Gu, Li-Hong
    Gu, Guang-Xiang
    Wan, Ping
    Li, Feng-Hua
    Xia, Qiang
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2021, 20 (01) : 46 - 52
  • [45] The utility of two-dimensional shear wave elastography and texture analysis for monitoring liver fibrosis in rat model
    Li-Hong Gu
    Guang-Xiang Gu
    Ping Wan
    Feng-Hua Li
    Qiang Xia
    Hepatobiliary & Pancreatic Diseases International, 2021, 20 (01) : 46 - 52
  • [46] Analysis of Point Shear Wave Elastography and Biochemical Markers for the Detection of Liver Fibrosis
    Cebula, Maciej
    Gruszczynska, Katarzyna
    Hartleb, Marek
    Baron, Jan
    MEDICINA-LITHUANIA, 2021, 57 (01): : 1 - 7
  • [47] Shear wave elastography correlates with liver fibrosis scores in pediatric patients with liver disease
    Farmakis, Shannon G.
    Buchanan, Paula M.
    Guzman, Miguel A.
    Hardy, Anna K.
    Jain, Ajay K.
    Teckman, Jeffrey H.
    PEDIATRIC RADIOLOGY, 2019, 49 (13) : 1742 - 1753
  • [48] Comparison of Visual Transient Elastography and Shear Wave Elastography in Evaluating Liver Fibrosis in Patients with Chronic Liver Disease
    Yang, Jiali
    Li, Jiawu
    Ye, Guilin
    Luo, Yan
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 3553 - 3561
  • [49] Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis
    Kim, Dong Wook
    Suh, Chong Hyun
    Kim, Kyung Won
    Pyo, Junhee
    Park, Chan
    Jung, Seung Chai
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (06) : 880 - 893
  • [50] Shear wave elastography correlates with liver fibrosis scores in pediatric patients with liver disease
    Shannon G. Farmakis
    Paula M. Buchanan
    Miguel A. Guzman
    Anna K. Hardy
    Ajay K. Jain
    Jeffrey H. Teckman
    Pediatric Radiology, 2019, 49 : 1742 - 1753