Energy-Saving and Decarbonization Design Optimization for School Canteen Buildings: A Case Study in Nanjing

被引:0
|
作者
Zhang, Yuhan [1 ]
Hu, Kai [1 ]
Yang, Yankai [1 ]
Li, Depeng [2 ]
Deng, Tao [2 ]
Hu, Zhongping [3 ]
Xu, Yizhe [1 ]
机构
[1] Nanjing Tech Univ, Coll Urban Construct, 200 North Zhongshan Rd, Nanjing 210009, Peoples R China
[2] China Construct Ind & Energy Engn Grp Co Ltd, 6 Wenlan Rd, Nanjing 210046, Peoples R China
[3] China Construct Yipin Investment & Dev Co Ltd, Wuhan 430070, Peoples R China
基金
中国博士后科学基金;
关键词
educational buildings retrofitting; energy-saving design; decarbonization design; lifecycle carbon emissions; design optimization; Strengthened Elitist Genetic Algorithm (SEGA); CARBON; GREEN;
D O I
10.3390/buildings15030455
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In light of global climate change and China's commitment to carbon neutrality by 2060, this study explores energy-saving and decarbonization design optimization for educational buildings, with a specific focus on a high school canteen in Nanjing. Through a comparative analysis of optimal energy-saving and lifecycle decarbonization retrofit schemes, the study aims to identify the performance differences and provide practical guidance for retrofitting educational buildings. The optimization process involves two separate single-objective optimizations: one aimed at minimizing annual total primary energy consumption (TES) and the other at minimizing lifecycle carbon emissions (E). Energy performance is simulated using EnergyPlus 23.1.0, while the Strengthened Elitist Genetic Algorithm (SEGA) is applied to optimize design variables such as insulation materials, window types, window-to-wall ratios (WWRs), and photovoltaic (PV) system configurations. The results reveal that the optimal energy-saving scheme achieves zero net energy consumption annually, generating a surplus of 20,625.2 kWh (15.05 kWh/m2). Conversely, the optimal decarbonization scheme achieves zero lifecycle carbon emissions, contributing a carbon reduction of 386,926.4 kg, albeit with a 28.83% higher lifecycle TES compared to the energy-saving scheme. This study underscores the distinctions between energy-saving and decarbonization retrofits and offers valuable insights for sustainable retrofitting of educational buildings in China.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Optimization research on energy-saving and life-cycle decarbonization retrofitting of existing school buildings: A case study of a school in Nanjing
    Xu, Yizhe
    Yan, Chengchu
    Wang, Guanqun
    Shi, Jingfeng
    Sheng, Kai
    Li, Jun
    Jiang, Yanlong
    SOLAR ENERGY, 2023, 254 : 54 - 66
  • [2] The Study on Green Energy-saving Buildings Design
    Li Weifang
    PROCEEDINGS OF THE 2015 INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT SCIENCE AND MATERIALS, 2015, 40 : 1149 - 1153
  • [3] Multiobjective Optimization Method for Energy-Saving Design of Green Buildings
    Yang, Yuanting
    Lu, Fengxiang
    Qing, Lan
    ADVANCES IN CIVIL ENGINEERING, 2024, 2024
  • [4] Case Study of An Energy-Saving Game for Public Buildings
    Cheng, Zhijin
    Zhao, Qianchuan
    Basar, Tamer
    2018 IEEE 14TH INTERNATIONAL CONFERENCE ON AUTOMATION SCIENCE AND ENGINEERING (CASE), 2018, : 684 - 689
  • [5] Energy-saving renovation of old urban buildings: A case study of Beijing
    Zhang, Xinxin
    Nie, Shangyang
    He, Maogang
    Wang, Jingfu
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [6] Design optimization of passive PCM-enhanced hospital buildings for efficient energy-saving
    Zhang, Weiyi
    Shi, Yuan
    Yang, Haibin
    Zou, Yang
    Cao, Xiangpeng
    Cui, Hongzhi
    JOURNAL OF ENERGY STORAGE, 2024, 91
  • [7] Study on Energy-Saving Transformation Technologies for Green Buildings
    Yang, Yupeng
    PROCEEDINGS OF THE 2015 3RD INTERNATIONAL CONFERENCE ON MANAGEMENT SCIENCE, EDUCATION TECHNOLOGY, ARTS, SOCIAL SCIENCE AND ECONOMICS (MSETASSE 2015), 2015, 41 : 19 - 22
  • [8] Study on energy-saving strategy and application of intelligent buildings
    Architecture Design and Research Institute, Chongqing University, Chongqing 400045, China
    不详
    不详
    不详
    Chongqing Jianzhu Daxue Xuebao, 2006, 3 (99-101):
  • [9] Energy-saving parameterized design of buildings based on genetic algorithm
    Zhang, Kele
    INTERNATIONAL JOURNAL OF BUILDING PATHOLOGY AND ADAPTATION, 2020, 38 (05) : 785 - 795
  • [10] Lighting design of university buildings based on green energy-saving
    Dong, Wei
    Pan, Shanchuan
    Zhou, Dao
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING SUSTAINABILITY, 2023, 177 (01) : 31 - 38