Rethinking mechanical heart valves in the aortic position: new paradigms in design and testing

被引:0
|
作者
Chakraborty, Sreyashi [1 ]
Simon, Melinda G. [1 ]
Bellofiore, Alessandro [1 ]
机构
[1] San Jose State Univ, Biomed Engn Dept, San Jose, CA 95192 USA
来源
关键词
mechanical heart valves; thrombogenicity; aortic valve replacement; hemodynamics; particle image velocimetry; TURBULENCE CHARACTERISTICS DOWNSTREAM; INDUCED PLATELET ACTIVATION; PARTICLE IMAGE VELOCIMETRY; ARTIFICIAL-HEART; IN-VITRO; COHERENT STRUCTURES; FLUID-MECHANICS; BLOOD DAMAGE; NUMERICAL-SIMULATION; CLOSING DYNAMICS;
D O I
10.3389/fcvm.2024.1458809
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bileaflet mechanical heart valves (MHV) remain a viable option for aortic valve replacement, particularly for younger patients and patients from low- and middle-income countries and underserved communities. Despite their exceptional durability, MHV recipients are at increased risk of thromboembolic complications. As such, the development of the next generation of MHVs must prioritize improved thromboresistance and aim for independence from anticoagulant therapy. However, innovation in MHV design faces several challenges: strict performance and biocompatibility requirements, limited understanding of the mechanisms underlying MHV thrombosis, and a lack of effective testing methodologies to assess how design variations impact both hemodynamic performance and thrombogenicity of MHVs. This paper reviews the emerging paradigms in MHV design, materials and surface modifications that may inspire the development of a new generation of MHVs for aortic valve replacement. We also discuss challenges and opportunities in developing experimental and numerical approaches to achieve a more comprehensive understanding of MHV flow features and the mechanisms of flow-induced blood clotting.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Tubular heart valves: A new tissue prosthesis design - Preclinical evaluation of the 3F aortic bioprosthesis
    Cox, JL
    Ad, N
    Myers, K
    Gharib, M
    Quijano, RC
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (02): : 520 - 527
  • [32] Retrieval analysis of mechanical heart valves: Impact on design and clinical practice
    Cromheecke, ME
    Overkamp, PJB
    de Mol, BAJM
    van Gaalen, GL
    Becker, AE
    ARTIFICIAL ORGANS, 1998, 22 (09) : 794 - 799
  • [33] The integrated design of mechanical bi-leaflet prosthetic heart valves
    David, T
    Hsu, CH
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (06) : 452 - 462
  • [34] Design and fabrication of a mock circulatory system for reliability tests on aortic heart valves
    Singh, Dhruv
    Singhal, Abhishek
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 753 - 754
  • [35] Design of a Cyclic Pressure Bioreactor for the Ex Vivo Study of Aortic Heart Valves
    Schipke, Kimberly J.
    To, S. D. Filip
    Warnock, James N.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (54):
  • [36] INVITRO COMPARISON OF AORTIC HEART-VALVE PROSTHESES .1. MECHANICAL VALVES
    KNOTT, E
    REUL, H
    KNOCH, M
    STEINSEIFER, U
    RAU, G
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1988, 96 (06): : 952 - 961
  • [37] NEW TECHNIQUE FOR MOUNTING AND TESTING FRAME-SUPPORTED HOMOGRAFT AORTIC VALVES
    DONNELLY, RJ
    DEXTER, F
    DEVERALL, PB
    WATSON, DA
    THORAX, 1971, 26 (02) : 174 - &
  • [38] Anticoagulation in pregnant women with mechanical heart valves: the new ESC guidelines
    Pieper, P. G.
    2ND INTERNATIONAL CONGRESS ON CARDIAC PROBLEMS IN PREGNANCY (CPP 2012), 2012, : 17 - 22
  • [39] First Experience of Hydrodynamic Testing of Pediatric Heart Valve Bioprostheses in the Aortic Position
    Kostava V.T.
    Telyshev D.V.
    Zelivyanskaya M.V.
    Efimov I.A.
    Lyutova I.G.
    Pugovkin A.A.
    Biomedical Engineering, 2023, 56 (06) : 384 - 386
  • [40] PARACORPOREAL PUMP WITH NEW VALVES FOR ATRIO-AORTIC LEFT HEART ASSIST
    RENNEKAMP, F
    CLEVERT, HD
    HENNIG, E
    BUCHERL, ES
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1979, 25 : 249 - 253