Swirl impact on the overall cooling characteristics of an effusion -cooled combustor liner with cylindrical and fan-shaped holes

被引:0
|
作者
Lu, Xiang [1 ]
Ji, Yongbin [2 ]
Ge, Bing [1 ]
Zang, Shusheng [1 ]
机构
[1] Shanghai Jiao Tong Univ, Key Lab Power Machinery & Engn, Shanghai 200240, Peoples R China
[2] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin, Peoples R China
关键词
Swirl impact; Effusion cooling; Cylindrical and fan-shaped holes; Overall cooling effectiveness; Flow characteristics; DENSITY; ANGLE;
D O I
10.1016/j.ijheatfluidflow.2024.109688
中图分类号
O414.1 [热力学];
学科分类号
摘要
The swirl impact on the overall effusion cooling characteristics is investigated. Two typical hole configurations, cylindrical and fan-shaped holes, are studied under different blowing ratios (BR). The overall cooling effectiveness is obtained by IR camera and the flow features are analyzed by simulations. The result shows that the typical cooling characteristic is the existence of low-effectiveness regions at where the swirl impact the wall. The reason for this is that the swirl flows destroy the cooling film and suppress the cooling air, resulting in poor cooling effectiveness. At the plate beginning, the cooling effectiveness is high because the corner recirculation pushes the cooling air upstream to cover the wall. The ending of the plate has the best cooling performance due to the gradually superimposed cooling film. Increasing the BR weakens the influence of the swirl impact and improves the cooling effects, therefore the area average cooling effectiveness of the cylindrical holes increases from 0.334 to 0.688 and the cooling effectiveness unevenness decreases from 0.042 to 0.036. The fan-shaped holes have a maximum of 0.063 higher cooling effectiveness due to better film coverage. However, the fanshaped holes have a stronger cooling effectiveness unevenness, which is 0.012 higher. And the lowest cooling effectiveness is 0.133 and 0.146 lower than the area average value for the cylindrical and fan-shaped holes, respectively. The reason for this is that the fan-shaped holes have similarly poor film cooling in the swirl impact zone but better film cooling effectiveness in the other regions.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Effect of Spanwise Hole-to-Hole Spacing on Overall Cooling Effectiveness of Effusion Cooled Combustor Liners for a Swirl-Stabilized Can Combustor
    Ahmed, Shoaib
    Wahls, Benjamin H.
    Ekkad, Srinath V.
    Lee, Hanjie
    Ho, Yin-Hsiang
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2022, 144 (07):
  • [32] COMPARISON OF THE COOLING PERFORMANCE OF CYLINDRICAL AND FAN-SHAPED COOLING HOLES WITH SPECIAL EMPHASIS ON THE EFFECT OF INTERNAL COOLANT CROSS-FLOW
    Saumweber, Christian
    Schulz, Achmed
    PROCEEDINGS OF THE ASME TURBO EXPO 2008, VOL 4, PTS A AND B, 2008, : 893 - 903
  • [33] EXPERIMENTAL STUDY ON OVERALL COOLING EFFECTIVENESS OF SWIRL-STABILIZED MODEL COMBUSTOR WITH EFFUSION COOLING
    Ji, Yongbin
    Zhang, Liang
    Jin, Ming
    Ge, Bing
    Zang, Shusheng
    Xin, Jianhua
    Wu, Weiliang
    Li, Mingjia
    Xu, Wenyan
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 5A, 2019,
  • [34] Film Cooling Effectiveness on a Convex and Flat Surface in Conditions of Pulsed Blowing through Fan-Shaped and Cylindrical Holes
    A. V. Il’inkov
    A. V. Shchukin
    V. V. Takmovtsev
    A. V. Starodumov
    Russian Aeronautics, 2024, 67 (3): : 610 - 617
  • [35] The characteristics and divergence of fan-shaped and cylindrical holes on the suction side of a turbine blade under rotating conditions
    Li, Haiwang
    Zhao, Guoqin
    Zhou, Zhiyu
    Wang, Haichao
    You, Ruquan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 139 : 432 - 441
  • [36] EFFUSION COOLED COMBUSTOR LINER TILES WITH MODERN COOLING CONCEPTS: A COMPARATIVE EXPERIMENTAL STUDY
    Jackowski, Thomas
    Schulz, Achmed
    Bauer, Hans-Joerg
    Gerendas, Miklos
    Behrendt, Thomas
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2016, VOL 5B, 2016,
  • [37] Turbine Blade Platform Film Cooling With Fan-Shaped Holes Under Simulated Swirl Purge Flow and Slashface Leakage Conditions
    Chen, Andrew F.
    Shiau, Chao-Cheng
    Han, Je-Chin
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2018, 140 (01):
  • [38] Comparisons of cooling performance and flow characteristics of a combustor liner plate with compound angle and simple angle effusion holes
    Kwon, Hwabhin
    Ligrani, Phillip M.
    Vanga, Sneha R.
    Park, Heesung
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 185
  • [39] Effect of hole geometry on the thermal performance of fan-shaped film cooling holes
    Gritsch, M
    Colban, W
    Schär, H
    Döbbeling, K
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2005, 127 (04): : 718 - 725
  • [40] Endwall film cooling through fan-shaped holes with different area ratios
    Barigozzi, Giovanna
    Franchini, Giuseppe
    Perdichizzi, Antonio
    Proceedings of the ASME Turbo Expo 2006, Vol 3, Pts A and B: HEAT TRANSFER: GENERAL INTEREST, 2006, : 599 - 609