Assessment of the cold storage performance of a device used in deep frozen cold chain

被引:0
|
作者
Spijkers, Rick [1 ]
Damas, Alain [2 ]
Vanapalli, Srinivas [1 ]
机构
[1] Univ Twente, Appl Thermal Sci Lab, Postbus 217, NL-7500 AE Enschede, Netherlands
[2] Air Liquide, 1 Chemin Porte Loges, F-78350 Paris, France
关键词
Dry-shipper; Cryo Cold Chain; Liquid Nitrogen;
D O I
10.18462/iir.icr.2023.0199
中图分类号
O414.1 [热力学];
学科分类号
摘要
Dry-shipper is a technical name for a device used to transport deep frozen biomedical samples. The device contains a porous material filled with liquid nitrogen to avoid the hazard of a spillage during transportation. The factors influencing the evaporation rate of liquid nitrogen in the device is of crucial importance to guarantee the safe storage of the frozen samples. We measured the weight and temperature of the dry-shipper during normal operation. The mass of a fully charged dry-shipper decreased linearly with time indicating a fairly constant rate of liquid nitrogen evaporation. The temperature of the sample holder remained at a fairly constant value for about 30 days. After all the liquid nitrogen had evaporated, we would expect an exponential increase of the dry-shipper temperature. However, the increase observed is linear. The reasons for this uncharacteristic behaviour of the device are investigated. The heat leak and the heat capacity of the system is determined from the evaporation rate and the warmup curve, respectively. The experimental data and the accompanying physical model give insights into the main physical parameters contributing to the evaporation of liquid nitrogen in the dry-shipper.
引用
收藏
页码:584 / 592
页数:9
相关论文
共 50 条
  • [21] Early Experience with a New Storage Device for Cold Preservation
    Goekler, J.
    Angleitner, P.
    Moayedifar, R.
    Johann, H.
    Aliabadi-Zuckermann, A.
    Laufer, G.
    Zuckermann, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S197 - S197
  • [22] First Experience with a New Storage Device for Cold Preservation
    Goekler, J.
    Zuckermann, A.
    Angleitner, P.
    Ceran, E.
    Kaiser, P.
    Neuber, N.
    Horvat, J.
    Laufer, G.
    Aliabadi-Zuckermann, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S244 - S244
  • [23] A sustainable framework development and assessment for enhancing the environmental performance of cold supply chain
    Kumar, Neeraj
    Tyagi, Mohit
    Sachdeva, Anish
    MANAGEMENT OF ENVIRONMENTAL QUALITY, 2023, 34 (04) : 1077 - 1110
  • [24] Frozen, Cold, or Cool? Chemical Assessment of the Effectiveness of Storage Conditions for Celluloid 3D Objects
    Elsaesser, Christina
    Angelin, Eva Mariasole
    Montag, Peter
    Hilbig, Harald
    Grosse, Christian U.
    Pamplona, Marisa
    POLYMERS, 2023, 15 (20)
  • [25] DESIGN AND OPTIMIZATION OF PCM-AIR COLD ENERGY STORAGE DEVICE TO BE USED FOR PEAK ELECTRICITY SHAVING
    Turkakar, Goker
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2021, 41 (01) : 23 - 36
  • [26] The aroma profile of frozen green peas used for cold or warm consumption
    Hansen, M
    Jakobsen, HB
    Christensen, LP
    FRONTIERS OF FLAVOUR SCIENCE, 2000, : 69 - 73
  • [27] STORAGE OF VACCINES IN THE COMMUNITY - WEAK LINK IN THE COLD CHAIN
    THAKKER, Y
    WOODS, S
    BRITISH MEDICAL JOURNAL, 1992, 304 (6829): : 756 - 758
  • [28] Form-stable cold storage phase change materials with durable cold insulation for cold chain logistics of food
    Zhang, Yuang
    Xu, Yanqun
    Lu, Rongwen
    Zhang, Shufen
    Hai, Abdul Moqeet
    Tang, Bingtao
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2023, 203
  • [29] VACCINE STORAGE AND TRANSPORTATION IN CANADA - COLD CHAIN SYSTEM
    不详
    CANADIAN FAMILY PHYSICIAN, 1992, 38 : 1982 - 1982
  • [30] Assessment of the cold storage capacity used in bulk handling of perishable agricultural produce in Ugandan cities
    Mukama, Matia
    Abaasa, Paula
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 165 : 233 - 244