Assessment of the cold storage performance of a device used in deep frozen cold chain

被引:0
|
作者
Spijkers, Rick [1 ]
Damas, Alain [2 ]
Vanapalli, Srinivas [1 ]
机构
[1] Univ Twente, Appl Thermal Sci Lab, Postbus 217, NL-7500 AE Enschede, Netherlands
[2] Air Liquide, 1 Chemin Porte Loges, F-78350 Paris, France
关键词
Dry-shipper; Cryo Cold Chain; Liquid Nitrogen;
D O I
10.18462/iir.icr.2023.0199
中图分类号
O414.1 [热力学];
学科分类号
摘要
Dry-shipper is a technical name for a device used to transport deep frozen biomedical samples. The device contains a porous material filled with liquid nitrogen to avoid the hazard of a spillage during transportation. The factors influencing the evaporation rate of liquid nitrogen in the device is of crucial importance to guarantee the safe storage of the frozen samples. We measured the weight and temperature of the dry-shipper during normal operation. The mass of a fully charged dry-shipper decreased linearly with time indicating a fairly constant rate of liquid nitrogen evaporation. The temperature of the sample holder remained at a fairly constant value for about 30 days. After all the liquid nitrogen had evaporated, we would expect an exponential increase of the dry-shipper temperature. However, the increase observed is linear. The reasons for this uncharacteristic behaviour of the device are investigated. The heat leak and the heat capacity of the system is determined from the evaporation rate and the warmup curve, respectively. The experimental data and the accompanying physical model give insights into the main physical parameters contributing to the evaporation of liquid nitrogen in the dry-shipper.
引用
收藏
页码:584 / 592
页数:9
相关论文
共 50 条
  • [1] Research progress of phase change cold storage materials used in cold chain transportation and their different cold storage packaging structures
    Zhao, Yi
    Zhang, Xuelai
    Xu, Xiaofeng
    Zhang, Shihua
    JOURNAL OF MOLECULAR LIQUIDS, 2020, 319 (319)
  • [2] Cold chain storage
    Wilcock, M
    BRITISH JOURNAL OF GENERAL PRACTICE, 1996, 46 (405): : 256 - 256
  • [3] PERFORMANCE ASSESSMENT OF AN LNA USED AS ACTIVE COLD LOAD
    Sobjaerg, Sten Schmidl
    Balling, Jan E.
    Skou, Niels
    2015 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2015, : 4742 - 4745
  • [4] Assessment of Vaccine Storage and Cold Chain Management Practices in India
    Meshram, Priyanka K.
    Pise, Rainita R.
    Joshi, Abhishek U.
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2024, 13 (04) : 1578 - 1579
  • [5] Research progress of phase change cold energy storage materials used in cold chain logistics of aquatic products
    Feng, Tianping
    Ji, Jun
    Zhang, Xuelai
    JOURNAL OF ENERGY STORAGE, 2023, 60
  • [6] Model development and assessment for temperature processing technologies used in cold chain industries
    Kumar, Neeraj
    Tyagi, Mohit
    Sachdeva, Anish
    ADVANCES IN MATERIALS AND PROCESSING TECHNOLOGIES, 2024, 10 (03) : 2021 - 2044
  • [7] Assessing the thermal performance of three cold energy storage materials with low eutectic temperature for food cold chain
    Li, Yu-Chu M.
    Chen, Yen-Hong A.
    ENERGY, 2016, 115 : 238 - 256
  • [8] A COLD NEUTRON STORAGE DEVICE AND A NEUTRON RESONATOR
    SCHUSTER, M
    JERICHA, E
    CARLILE, CJ
    RAUCH, H
    PHYSICA B, 1992, 180 : 997 - 999
  • [9] Application and research progress of cold storage technology in cold chain transportation and distribution
    Zhao, Yi
    Zhang, Xuelai
    Xu, Xiaofeng
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 139 (02) : 1419 - 1434
  • [10] Application and research progress of cold storage technology in cold chain transportation and distribution
    Yi Zhao
    Xuelai Zhang
    Xiaofeng Xu
    Journal of Thermal Analysis and Calorimetry, 2020, 139 : 1419 - 1434