Impact of General Anesthesia on Ciliary Functional Analysis by Digital High-Speed Videomicroscopy in Suspected Primary Ciliary Dyskinesia

被引:0
|
作者
Benchimol, Lionel [1 ]
Bricmont, Noemie [2 ,3 ]
Bonhiver, Romane [2 ,3 ]
Hans, Gregory [4 ]
Kempeneers, Celine [2 ,3 ]
Lefebvre, Philippe [1 ]
Poirrier, Anne-Lise [1 ]
机构
[1] Univ Hosp Liege, Dept ENT, Ave Hop 1, B-4000 Liege, Belgium
[2] Univ Liege, GIGA Res Ctr, Pneumol Lab, Grp I3, B-4000 Liege, Belgium
[3] Univ Hosp Liege, Dept Pediat, Div Respirol, B-4000 Liege, Belgium
[4] CHU Liege, Dept Anaesthesia & Intens Care Med, B-4000 Liege, Belgium
关键词
primary ciliary dyskinesia; digital high-speed videomicroscopy; general anesthesia; ENT surgeries; BEAT FREQUENCY; MOTILITY; PATTERN;
D O I
10.3390/diagnostics14212436
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Digital high-speed videomicroscopy (DHSV) is a crucial tool for evaluating ciliary function in children suspected of primary ciliary dyskinesia (PCD). However, until now, samples are taken without anesthesia due to uncertainty about its effect on ciliary function and DHSV interpretation. This study aimed to investigate the impact of general anesthesia on ciliary functional analysis by DHSV in a series of three patients listed for ENT surgeries, which could improve diagnostic procedures for pediatric patients. Patient 1 (7-year-old girl) underwent adenotonsillectomy and tympanostomy placement tube, while patients 2 (17-month-old boy) and 3 (15-month-old girl) underwent adenoidectomy and tympanostomy placement tube. All patients underwent nasal brushing before general anesthesia (control sample). Experimental samples were taken in the contralateral nostril at the time of equilibration of the anesthetic agents (sevoflurane, propofol, sufentanil). Ciliary beat frequency and pattern were measured using digital high-speed videomicroscopy. Our findings highlighted the variability of respiratory ciliary function under general anesthesia among individuals. Our results emphasize the need for caution when interpreting ciliary function data obtained during general anesthesia. Further research with larger cohorts is warranted for validation.
引用
收藏
页数:9
相关论文
共 44 条
  • [21] Quantitative High Speed Video Profiling Discriminates Between Variants of Primary Ciliary Dyskinesia
    Chioccioli, M.
    Feriani, L.
    Nguyen, Q.
    Kotar, J.
    Dell, S. D. M.
    Mennella, V.
    Amirav, I.
    Cicuta, P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [22] A QUANTITATIVE ANALYSIS OF CILIARY MOVEMENT BY MEANS OF HIGH-SPEED MICROCINEMATOGRAPHY
    BABA, SA
    HIRAMOTO, Y
    JOURNAL OF EXPERIMENTAL BIOLOGY, 1970, 52 (03): : 675 - +
  • [23] Quantitative High-Speed Video Profiling Discriminates between DNAH11 and HYDIN Variants of Primary Ciliary Dyskinesia
    Chioccioli, Maurizio
    Feriani, Luigi
    Quynh Nguyen
    Kotar, Jurij
    Dell, Sharon D.
    Mennella, Vito
    Amirav, Israel
    Cicuta, Pietro
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199 (11) : 1436 - 1438
  • [24] Exploring the Art of Ciliary Beating The Benefits of High-Speed Video Analysis
    Lucas, Jane S.
    Evans, Hazel J.
    Haarman, Eric G.
    Hirst, Robert A.
    Hogg, Claire
    Jackson, Claire L.
    Nielsen, Kim G.
    Omran, Heymut
    Papon, Jean Francois
    Robinson, Phil
    Shoemark, Amelia
    Walker, Woolf T.
    CHEST, 2017, 152 (06) : 1348 - 1349
  • [25] Nasal Brushing Sampling and Processing using Digital High Speed Ciliary Videomicroscopy - Adaptation for the COVID-19 Pandemic
    Bricmont, Noemie
    Benchimol, Lionel
    Poirrier, Anne-Lise
    Grignet, Christine
    Seaton, Claire
    Chilvers, Mark A.
    Seghaye, Marie-Christine
    Louis, Renaud
    Lefebvre, Philippe
    Kempeneers, Celine
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (165): : 1 - 30
  • [26] High through-put computerised image analysis for primary ciliary dyskinesia diagnostics
    Jackson, C. L.
    Pathmanathan, N.
    Coles, J. L.
    Chatelet, D.
    Fryatt, G.
    Lucas, J. S.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [27] ANALYSIS OF 3-DIMENSIONAL CILIARY BEATING BY MEANS OF HIGH-SPEED STEREOMICROSCOPY
    TEUNIS, PFM
    MACHEMER, H
    BIOPHYSICAL JOURNAL, 1994, 67 (01) : 381 - 394
  • [28] Exploring the Art of Ciliary Beating The Benefits of High-Speed Video Analysis Reply
    Kempeneers, Celine
    Seaton, Claire
    Chilvers, Mark A.
    CHEST, 2017, 152 (06) : 1349 - 1350
  • [29] Mutation scanning for mutations associated with primary ciliary dyskinesia by high-resolution melting analysis
    Chao, K. C.
    Zariwala, M.
    Langley, M.
    Warren, C. L.
    Knowles, M. R.
    Weck, K.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2007, 9 (05): : 653 - 653
  • [30] Genetic Analysis of Korean Adult Patients with Nontuberculous Mycobacteria Suspected of Primary Ciliary Dyskinesia Using Whole Exome Sequencing
    Cho, Eun Hye
    Ki, Chang Seok
    Yun, Sun Ae
    Kim, Su Young
    Jhun, Byung Woo
    Koh, Won Jung
    Huh, Hee Jae
    Lee, Nam Yong
    YONSEI MEDICAL JOURNAL, 2021, 62 (03) : 224 - 230