Impact of General Anesthesia on Ciliary Functional Analysis by Digital High-Speed Videomicroscopy in Suspected Primary Ciliary Dyskinesia

被引:0
|
作者
Benchimol, Lionel [1 ]
Bricmont, Noemie [2 ,3 ]
Bonhiver, Romane [2 ,3 ]
Hans, Gregory [4 ]
Kempeneers, Celine [2 ,3 ]
Lefebvre, Philippe [1 ]
Poirrier, Anne-Lise [1 ]
机构
[1] Univ Hosp Liege, Dept ENT, Ave Hop 1, B-4000 Liege, Belgium
[2] Univ Liege, GIGA Res Ctr, Pneumol Lab, Grp I3, B-4000 Liege, Belgium
[3] Univ Hosp Liege, Dept Pediat, Div Respirol, B-4000 Liege, Belgium
[4] CHU Liege, Dept Anaesthesia & Intens Care Med, B-4000 Liege, Belgium
关键词
primary ciliary dyskinesia; digital high-speed videomicroscopy; general anesthesia; ENT surgeries; BEAT FREQUENCY; MOTILITY; PATTERN;
D O I
10.3390/diagnostics14212436
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Digital high-speed videomicroscopy (DHSV) is a crucial tool for evaluating ciliary function in children suspected of primary ciliary dyskinesia (PCD). However, until now, samples are taken without anesthesia due to uncertainty about its effect on ciliary function and DHSV interpretation. This study aimed to investigate the impact of general anesthesia on ciliary functional analysis by DHSV in a series of three patients listed for ENT surgeries, which could improve diagnostic procedures for pediatric patients. Patient 1 (7-year-old girl) underwent adenotonsillectomy and tympanostomy placement tube, while patients 2 (17-month-old boy) and 3 (15-month-old girl) underwent adenoidectomy and tympanostomy placement tube. All patients underwent nasal brushing before general anesthesia (control sample). Experimental samples were taken in the contralateral nostril at the time of equilibration of the anesthetic agents (sevoflurane, propofol, sufentanil). Ciliary beat frequency and pattern were measured using digital high-speed videomicroscopy. Our findings highlighted the variability of respiratory ciliary function under general anesthesia among individuals. Our results emphasize the need for caution when interpreting ciliary function data obtained during general anesthesia. Further research with larger cohorts is warranted for validation.
引用
收藏
页数:9
相关论文
共 44 条
  • [1] Impact of local anesthesia on ciliary dyskinesia diagnosis by digital high-speed videomicroscopy
    Benchimol, Lionel
    Bricmont, Noemie
    Bonhiver, Romane
    Hans, Gregory A.
    Lefebvre, Philippe
    Kempeneers, Celine
    Poirrier, Anne-Lise
    PEDIATRIC PULMONOLOGY, 2025, 60 (01)
  • [2] High-Speed Videomicroscopy Analysis Presents Limitations in Diagnosis of Primary Ciliary Dyskinesia
    Shapiro, Adam J.
    Ferkol, Thomas W.
    Manion, Michele
    Leigh, Margaret W.
    Davis, Stephanie D.
    Knowles, Michael R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201 (01) : 122 - 123
  • [3] High-Speed Videomicroscopy Analysis Presents Limitations in Diagnosis of Primary Ciliary Dyskinesia Reply
    Amirav, Israel
    Lavie, Moran
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201 (01) : 123 - 125
  • [4] Errors in Methodology Affect Diagnostic Accuracy of High-Speed Videomicroscopy Analysis in Primary Ciliary Dyskinesia
    Shapiro, Adam
    Leigh, Margaret
    Omran, Heymut
    Lavergne, Valery
    Knowles, Michael
    CHEST, 2019, 156 (05) : 1032 - 1033
  • [5] Errors in Methodology Affect Diagnostic Accuracy of High-Speed Videomicroscopy Analysis in Primary Ciliary Dyskinesia Response
    Lucas, Jane
    Rubbo, Bruna
    Jackson, Claire
    Hirst, Robert
    Hogg, Claire
    O'Callaghan, Christopher
    Reading, Isabel
    Shoemark, Amelia
    CHEST, 2019, 156 (05) : 1033 - 1034
  • [6] In Defense of High-Speed Video Microscopy in Evaluating Patients with Suspected Primary Ciliary Dyskinesia
    Lavie, Moran
    Amirav, Israel
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 200 (09) : 1181 - +
  • [7] Accuracy of High-Speed Video Analysis to Diagnose Primary Ciliary Dyskinesia
    Rubbo, Bruna
    Shoemark, Amelia
    Jackson, Claire L.
    Hirst, Robert
    Thompson, James
    Hayes, Joseph
    Frost, Emily
    Copeland, Fiona
    Hogg, Claire
    O'Callaghan, Christopher
    Reading, Isabel
    Lucas, Jane S.
    CHEST, 2019, 155 (05) : 1008 - 1017
  • [8] Accuracy of high-speed video microscopy to diagnose primary ciliary dyskinesia
    Rubbo, Bruna
    Reading, Isabel
    Shoemark, Amelia
    Jackson, Claire
    Hirst, Robert A.
    Thompson, James
    Hayes, Joseph
    Frost, Emily
    Copeland, Fiona
    O'Callaghan, Christopher
    Hogg, Claire
    Lucas, Jane S.
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [9] Advancing Primary Ciliary Dyskinesia Diagnosis through High-Speed Video Microscopy Analysis
    De Jesus-Rojas, Wilfredo
    Demetriou, Zachary J.
    Muniz-Hernandez, Jose
    Rosario-Ortiz, Gabriel
    Quinones, Frances M.
    Ramos-Benitez, Marcos J.
    Mosquera, Ricardo A.
    CELLS, 2024, 13 (07)
  • [10] Identification of distinct ciliary beat pattern abnormalities by high-speed video microscopy in primary ciliary dyskinesia
    Raidt, Johanna
    Wallmeier, Julia
    Hjeij, Rim
    Onnebrink, Joerg Grosse
    Olbrich, Heike
    Loges, Niki T.
    Pennekamp, Petra
    Dougherty, Gerard
    Haeffner, Karsten
    Omran, Heymut
    Werner, Claudius
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46