Renewable non-enzymatic copper-based surfaces for the detection of glucose, fructose, sucrose, and galactose

被引:0
|
作者
Aun, Adam Tan Tiek [1 ]
Salleh, Noordini Mohamad [1 ]
Ali, Umi Fazara Md [2 ,3 ]
Basirun, Wan Jefrey [1 ]
Chang, Yu-Hsu [4 ]
Manan, Ninie Suhana Abdul [1 ]
机构
[1] Univ Malaya, Fac Sci, Dept Chem, Kuala Lumpur 50603, Malaysia
[2] Univ Malaysia Perlis, Fac Chem Engn & Technol, Kompleks Pusat Pengajian Jejawi 3, Arau 02600, Perlis, Malaysia
[3] Univ Malaysia Perlis, Ctr Excellent Biomass Utilizat COEBU, Kompleks Pusat Pengajian Jejawi 3, Arau 02600, Perlis, Malaysia
[4] Natl Taipei Univ Technol, Inst Mineral Resources Engn, Dept Mat & Mineral Resources Engn, Taipei 10608, Taiwan
关键词
Copper-based; Sugar sensor; Non-enzymatic; Copper oxide; OXIDE; FABRICATION; ELECTRODE; SENSORS;
D O I
10.1016/j.jfca.2024.107119
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
This study aims to circumvent the environmental and logistical drawbacks of disposable electrode strips by developing Cu-based sugar sensors that can be renewed for use. In this work, Cu-based sugar sensors were prepared through the electrodeposition of CuAg or lactate-templated Cu onto a carbon paste electrode (CPE) followed by electrochemical oxidation in a sodium hydroxide solution. Users can perform this process themselves by using a pre-programmed power supply and following the provided instructions. Important synthesis parameters were initially screened using experiments with a 2k factorial design to identify the most crucial factors that affect the performance of the sugar sensor. Optimization was conducted using a central composite design when necessary. An optimal lactate-templated Cu oxide-based sugar sensor with an average sensitivity of 523 mu A cm2 mM- 1 and an optimal CuAg oxide-based sugar sensor with a sensitivity of 191 mu A cm2 mM- 1 are obtained. Cyclic voltammetry (CV) analysis revealed that the oxidation rate of glucose on CuAg and lactate-templated Cu oxide-based sugar sensors is limited by surface kinetics. Electrochemical impedance spectroscopy (EIS) revealed that increasing glucose concentration in the electrolyte causes a decrease in charge transfer resistance (Rct). A higher glucose level results in better electron transfer and therefore a higher proportional current. Field emission scanning electron microscopy (FESEM) revealed that both CuAg and lactate-templated Cu oxide-based sugar sensors produced under optimized conditions also have better active material coverage and more uniquely shaped nanostructures. Energy-dispersive X-ray spectroscopy (EDX) analysis revealed that both the optimal CuAg oxide-based sugar sensor and the lactate-templated Cu oxide-based sugar sensor have a higher oxygen-to-copper ratio, which could positively influence their catalytic properties. The current density of both sensor types was found to decline over a period of 10 days. The CuAg oxide-based sugar sensor suffered an average drop of 27.10% in current density and lactate-templated Cu oxide suffered an average drop of 31.4% in current density. Additionally, when subjected to a constant potential of 0.5 V in a 6.04 mM glucose solution for 12 hours, both sensors displayed a significant decline in current density, 40.3 % for the CuAg oxide-based sugar sensor and 45.0 % for the lactate-templated Cu oxide -based sugar sensor. However, the sugar sensors can be renewed easily after each use, circumventing the issue of electrode stability.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Copper-based Metal-organic Framework for Non-enzymatic Electrochemical Detection of Glucose
    Sun, Yanmei
    Li, Yaxiang
    Wang, Nan
    Xu, Qing Qing
    Xu, Ling
    Lin, Meng
    ELECTROANALYSIS, 2018, 30 (03) : 474 - 478
  • [2] Facile copper-based nanofibrous matrix for glucose sensing: Eenzymatic vs. non-enzymatic
    Apetrei, Roxana-Mihaela
    Camurlu, Pinar
    BIOELECTROCHEMISTRY, 2021, 140
  • [3] Electrochemically derived CuO nanorod from copper-based metal-organic framework for non-enzymatic detection of glucose
    Kim, Kijun
    Kim, Sungjin
    Lee, Ho Nyun
    Park, Young Min
    Bae, Youn-Sang
    Kim, Hyun-Jong
    APPLIED SURFACE SCIENCE, 2019, 479 : 720 - 726
  • [4] NON-ENZYMATIC ELECTROCHEMICAL GLUCOSE DETECTION
    TINDALL, CE
    MCMULLEN, JK
    MORROW, DJ
    IRISH JOURNAL OF MEDICAL SCIENCE, 1985, 154 (07) : 288 - 288
  • [5] Ultrasensitive and selective non-enzymatic glucose detection using copper nanowires
    Zhang, Yuchan
    Su, Liang
    Manuzzi, Dan
    de los Monteros, Honorio Valdes Espinosa
    Jia, Wenzhao
    Huo, Danqun
    Hou, Changjun
    Lei, Yu
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 426 - 432
  • [6] Non-enzymatic amperometric sensing of glucose by employing sucrose templated microspheres of copper oxide (CuO)
    Saraf, Mohit
    Natarajan, Kaushik
    Mobin, Shaikh M.
    DALTON TRANSACTIONS, 2016, 45 (13) : 5833 - 5840
  • [7] Non-Enzymatic Glucose Sensor Based on Copper Nanoparticles Modified Microelectrode
    Wang, Fang
    Sun, Xianping
    Chen, Yan
    Xie, Shijing
    Chen, Zilin
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2013, 5 (06) : 624 - 629
  • [8] Porous Copper Oxide Thin Film Electrodes for Non-Enzymatic Glucose Detection
    Carinelli, Soledad
    Salazar-Carballo, Pedro A.
    Melian, Julio Ernesto De la Rosa
    Garcia-Garcia, Francisco
    CHEMOSENSORS, 2023, 11 (05)
  • [9] Fabrication of Efficient and Non-Enzymatic Electrochemical Sensors for the Detection of Sucrose
    Asghar, Nazia
    Mustafa, Ghulam
    Jabeen, Nawishta
    Dawood, Asadullah
    Rida
    Jabeen, Zeenat
    Malik, Qaiser Hameed
    Khan, Muhammad Asad
    Khan, Muhammad Usman
    SENSORS, 2023, 23 (04)
  • [10] CuO nanowires based sensitive and selective non-enzymatic glucose detection
    Zhang, Yuchan
    Liu, Yixin
    Su, Liang
    Zhang, Zhonghua
    Huo, Danqun
    Hou, Changjun
    Lei, Yu
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 86 - 93