Diagnostic Performance of Visionix VX120+ Platform for Dry Eye Screening

被引:0
|
作者
Martinez-Plaza, Elena [1 ,2 ]
Barberan-Bernardos, Laura [1 ]
Molina-Martin, Ainhoa [1 ]
Pinero, David P. [1 ,3 ]
机构
[1] Univ Alicante, Dept Opt Pharmacol & Anat, Grp Opt & Visual Percept, Alicante 03690, Spain
[2] Univ Valladolid, Valladolid 47001, Spain
[3] Vithas Medimar Int Hosp, Dept Ophthalmol, Alicante 03016, Spain
关键词
tear meniscus height; TMH; tear break-up time; NIBUT; accuracy; Visionix; dry eye; screening; TEAR FILM STABILITY; BREAK-UP TIME; FLUORESCEIN; CORNEAL; DISEASE; VOLUME;
D O I
10.3390/diagnostics14202276
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the accuracy of diagnosing dry eye disease (DED) by using the Visionix VX120+, to establish reference values for tear meniscus height (TMH) and non-invasive break-up time (NIBUT), and to compare the NIBUT measurements with the fluorescein tear break-up time (FBUT), Methods: fifty-eight subjects (34 dry eye and 24 control) were enrolled. The TMH, first NIBUT, and NIBUT50% were evaluated with the Visionix VX120+, and the FBUT was measured with a slit-lamp. The Receiver Operating Characteristic (ROC) curve was used to evaluate the diagnostic performance, and the Bland-Altman method was performed to analyze the agreement. Results: The areas under the curve were 0.62, 0.60, and 0.70 for the TMH, first NIBUT, and NIBUT50%, respectively. The optimal cut-off values (sensitivity, specificity) were 0.29 (0.62, 0.67), 5.05 (0.85, 0.46), and 7.35 (0.65, 0.79) for the TMH, first NIBUT, and NIBUT50%, respectively. The mean differences (lower, upper limits of agreement) were -1.10 (-8.78, 6.58) and 1.55 (-5.68, 8.78) for the first NIBUT vs. FBUT and the NIBUT50% vs. FBUT, respectively. Conclusions: In conclusion, the NIBUT50% can be a useful tool for dry eye screening, with acceptable values of sensitivity and specificity. First, the NIBUT and NIBUT50% should not be used interchangeably with the FBUT.
引用
收藏
页数:9
相关论文
共 21 条
  • [1] Agreement of Tear Break-Up Time and Meniscus Height between Medmont E300 and Visionix VX120+
    Martinez-Plaza, Elena
    Molina-Martin, Ainhoa
    Pinero, David P.
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [2] Diagnostic Performance of McMonnies Questionnaire as a Screening Survey for Dry Eye: A Multicenter Analysis
    Guo, Yuxin
    Peng, Rongmei
    Feng, Kang
    Hong, Jing
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [3] Dry eye diagnostic tests and surveys: performance and association
    Nichols, Kelly K.
    Smith, Janine A.
    2000, Williams & Wilkins Co, Baltimore (77)
  • [4] Validation of refraction and anterior segment parameters by a new multi-diagnostic platform (VX120)
    Gordon-Shaag, Ariela
    Pinero, David P.
    Kahloun, Cyril
    Markov, David
    Parnes, Tzadok
    Gantz, Liat
    Shneor, Einat
    JOURNAL OF OPTOMETRY, 2018, 11 (04) : 242 - 251
  • [5] Diagnostic performance of a tear protein panel in early dry eye
    Versura, Piera
    Bavelloni, Alberto
    Grillini, Marco
    Fresina, Michela
    Campos, Emilio C.
    MOLECULAR VISION, 2013, 19 : 1247 - 1256
  • [6] The performance of the contact lens dry eye questionnaire as a screening survey for contact lens-related dry eye
    Nichols, JJ
    Mitchell, GL
    Nichols, KK
    Chalmers, R
    Begley, C
    CORNEA, 2002, 21 (05) : 469 - 475
  • [7] Screening Questionnaire for Documentation of Medical History and Diagnostic Findings in Dry Eye Disease
    Jacobi, C.
    Bellios, N.
    Jacobi, A.
    Kruse, F.
    Cursiefen, C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2011, 228 (03) : 226 - 233
  • [8] Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease
    Vigo, Luca
    Pellegrini, Marco
    Bernabei, Federico
    Carones, Francesco
    Scorcia, Vincenzo
    Giannaccare, Giuseppe
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [9] Diagnostic performance of electrical ocular surface resistance for dry eye disease
    Hernandez-Quintela, Everardo
    Ramos Betancourt, Nallely
    Gonzalez-Dibildox, Alejandra
    Ramirez, Manuel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [10] Performance of Tear Osmolarity Compared to Previous Diagnostic Tests for Dry Eye Diseases
    Versura, P.
    Profazio, V.
    Campos, E. C.
    CURRENT EYE RESEARCH, 2010, 35 (07) : 553 - 564