Combining D-dimer and LDL/HDL ratio to predict the absence of atrial fibrillation in patients with an Implantable Loop Recorder for embolic stroke of Undetermined source

被引:0
|
作者
Yoshikawa, Kosuke [1 ]
Asano, Taku [1 ]
Onishi, Yoshimi [1 ,4 ]
Takai, Yuki [1 ]
Sugiyama, Hiroto [1 ]
Arai, Shuhei [1 ]
Gokan, Toshihiko [1 ]
Nakamura, Yuya [1 ]
Inokuchi, Koichiro [1 ]
Kikuchi, Miwa [3 ]
Onuki, Tatsuya [2 ]
Ezumi, Hitoshi [4 ]
Koba, Shinji [1 ]
Tanno, Kaoru [3 ]
Kobayashi, Youichi [1 ]
Shinke, Toshiro [1 ]
机构
[1] Showa Univ, Div Cardiol, Dept Med, Tokyo, Japan
[2] Showa Univ, Fujigaoka Hosp, Dept Med, Div Cardiol, Yokohama, Japan
[3] Showa Univ, Koto Toyosu Hosp, Cardiovasc Ctr, Tokyo, Japan
[4] Koyama Mem Hosp, Div Cardiol, Kashima, Ibaraki, Japan
来源
IJC HEART & VASCULATURE | 2025年 / 56卷
关键词
Atrial Fibrillation; Implantable Loop Recorder; Embolic Stroke of Undetermined Source; D-dimer; LDL/HDL cholesterol ratio; INSERTABLE CARDIAC MONITORS; CRYPTOGENIC STROKE; RISK; AGE; CONTRACTIONS; CHOLESTEROL; PREVENTION; DISEASE; SEX;
D O I
10.1016/j.ijcha.2025.101611
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objective: Embolic stroke of undetermined source (ESUS) patients undergoing long-term rhythm monitoring with Implantable Loop Recorder (ILR) have an atrial fibrillation (AF) detection rate of approximately 12 % at 1 year and 30 % with extended follow-up over 3 years. However, research specifically focusing on the majority of patients in whom AF is not detected through implantable cardiac monitors remains limited. Abnormal lipid profiles may be associated with embolic risks from non-AF sources. This study aimed to develop a model to predict the absence of AF in patients with ESUS using multiple variables, including lipid profiles. Methods: A retrospective, multicenter cohort study was conducted across four institutions, involving 99 ESUS patients. Patients were categorized based on AF detection via ILR. Patient characteristics, blood test results, and echocardiographic findings were assessed through univariate and multivariate logistic regression analyses. ROC curve analysis was performed to evaluate the biomarkers' predictive accuracy. Results: AF was detected in 30.3 % of patients over a median follow-up of 25.5 months. Multivariate analysis confirmed elevated D-dimer (OR: 2.77, p = 0.002), low LDL/HDL ratio (OR: 2.0, p = 0.01), and CHA2DS2-VASc score (OR: 1.4, p = 0.04) as independent predictors of AF detection. The CHA2DS2-VASc score was excluded due to multicollinearity, and patients with D-dimer < 0.9 mu g/ml and LDL/HDL ratio > 1.98 had significantly lower AF detection rates (6.8 %, P < 0.001; sensitivity 93.1 %, specificity 44.2 %). Conclusion: Combining D-dimer and LDL/HDL ratios provides an effective and accessible method for predicting the absence of AF in patients with an ILR for ESUS.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Diagnosis of Occult Atrial Fibrillation in Patients With Embolic Stroke of an Undetermined Source Based on Left Atrial Strain
    Maqsood, Hamza
    Jumani, Laraib
    Wazir, Momna
    Raza, Samina
    Munir, Maryam
    Noor, Nabeeha
    Mehmood, Saad
    Neelam, Fnu
    Gulraiz, Azouba
    Saleem, Hamza
    CIRCULATION, 2023, 148
  • [32] D-dimer can predict survival in patients with chronic atrial fibrillation
    Mahé, I
    Drouet, L
    Simoneau, G
    Minh-Muzeaux, S
    Caulin, C
    Bergmann, JF
    BLOOD COAGULATION & FIBRINOLYSIS, 2004, 15 (05) : 413 - 417
  • [33] Predicting the Propensity of Atrial Cardiopathy and Paroxysmal Atrial Fibrillation in Patients with Embolic Stroke of Undetermined Source (ESUS)
    Elbarbary, Mohammed
    Kishk, Ahmed
    Abdeldayem, Mohamed E.
    Khalil, Mohamed A.
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2025, 122 (01)
  • [34] Association of Global Cardiac Calcification with Atrial Fibrillation and Recurrent Stroke in Patients with Embolic Stroke of Undetermined Source
    Li, Tony Y. W.
    Yeo, Leonard L. L.
    Ho, Jamie S. Y.
    Leow, Aloysius S.
    Chan, Mark Y.
    Dalakoti, Mayank
    Chan, Bernard P. L.
    Seow, Swee-Chong
    Kojodjojo, Pipin
    Sharma, Vijay K.
    Tan, Benjamin Yong-Qiang
    Sia, Ching-Hui
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2021, 34 (10) : 1056 - 1066
  • [35] THE ROLE OF D-DIMER IN STROKE RISK STRATIFICATION IN PATIENTS WITH ATRIAL FIBRILLATION
    Rubanenko, A. O.
    Rubanenko, O. A.
    Dyachkov, V. A.
    Shchukin, Yu, V
    GEMATOLOGIYA I TRANSFUZIOLOGIYA, 2022, 67 (02): : 261 - 266
  • [36] Coexisting Cerebrovascular Disease and Risk of Occult Atrial Fibrillation in Patients With Embolic Stroke of Undetermined Source
    Rojo, Esther
    Sandin-Fuentes, Maria
    Calleja, Ana I.
    Largaespada, Gabriel
    Cortijo, Elisa
    Garcia-Moran, Emilio
    Ruiz-Pinero, Marina
    Garcia-Bermejo, Pablo
    Lopez-Mesonero, Luis
    Rubio, Jeronimo
    Arenillas, Juan F.
    STROKE, 2015, 46
  • [37] Atrial fibrillation after patent foramen ovale closure in patients with embolic stroke of undetermined source
    von Falkenhausen, Aenne S.
    Keidel, Linus M.
    Wischmann, Johannes
    Hoeglinger, Guenter
    Massberg, Steffen
    Kaeaeb, Stefan
    Kellert, Lars
    Sinner, Moritz F.
    EUROPACE, 2024, 26 (06):
  • [38] D-dimer levels and stroke progression in patients with acute ischemic stroke and atrial fibrillation
    Krarup, L-H.
    Sandset, E. C.
    Sandset, P. M.
    Berge, Eivind
    ACTA NEUROLOGICA SCANDINAVICA, 2011, 124 (01): : 40 - 44
  • [39] Incidence of atrial fibrillation and subsequent medication changes in cryptogenic stroke patients with an implantable loop recorder
    Ungar, A.
    Rieger, G.
    Puererfellner, H.
    Duru, F.
    De Melis, M.
    Bonizzi, T.
    Reinke, F.
    Bucx, J.
    Toepper, R. F.
    Kuster, S.
    EUROPEAN HEART JOURNAL, 2014, 35 : 292 - 292
  • [40] Comparison of Implantable Loop Recorder and Event Monitors for Diagnosis of Atrial fibrillation in Patients with Cryptogenic Stroke
    Salam, Smeer
    Grose, Noah
    Mease, Julie
    Afzal, Muhammad
    Hinduja, Archana
    Daoud, Emile
    NEUROLOGY, 2018, 90