Additively Manufactured Aperture-Based FSS

被引:1
|
作者
Hook, Alexander [1 ]
Motes, Doyle T., III [2 ]
Morrow, Cody [2 ]
Donnell, Kristen M. [1 ]
机构
[1] Missouri Univ Sci & Technol, Dept Elect & Comp Engn, Microwave Sensing Sense Lab, Rolla, MO 65409 USA
[2] Texas Res Inst TRI Austin Inc, Nondestruct Evaluat Div, Austin, TX USA
来源
2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024 | 2024年
关键词
Additive Manufacturing; Fused Deposition Modeling 3-D Printing; Frequency Selective Surface (FSS); Aperture-based Frequency Selective Surface; Conductive Printing;
D O I
10.1109/I2MTC60896.2024.10560971
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency selective surfaces (FSSs) are arrays of patch- or aperture-based elements with specific high frequency reflective and/or transmissive properties. The specific FSS response of a given design is dictated by the element dimensions and spacing relative to adjacent elements (collectively referred to as the unit cell), along with the substrate (and superstrate if applicable) properties. As it relates to sensing, the FSS response may be affected by environmental (e.g., temperature) or structural (e.g., strain) changes. To this end, FSS-based sensors have been considered in recent years for a myriad of sensing applications including structural health monitoring (SHM). Concurrent to this, the growth of additive manufacturing (AM) technologies has opened the door for in-situ printing of FSS-based sensors. To this end, this work studies the potential for Fused Deposition Modeling (FDM) type AM-fabricated FSS-based sensors. Of particular interest is the effect of the reduced electrical conductivity (common to currently available conductive FDM filaments) on the performance and repeatability of FDM-printed sensors. Results from this work show that aperture-based FSS designs maintain a resonant response when printed with a reduced-conductivity material, whereas patch-based designs no longer provide FSS functionality. In addition, the results of a measurement study on a set of five additive manufactured FSS (AM-FSS) sensors show good agreement between the simulations and measurements and a high level of measurement repeatability. For these reasons, aperture-based FSS sensors fabricated via the FDM-AM process using a reduced conductivity filament are a viable option for aperture-based FSS fabrication and sensing applications.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Quantitative comparison of aperture-based and beamlet-based inverse planning techniques
    Lo, A
    Shou, Z
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S630 - S630
  • [32] Structure and Aperture-Based Robustness Estimation for Volumetric Modulated Arc Therapy
    Mori, M.
    Saito, A.
    Kawahara, D.
    Miki, K.
    Murakami, Y.
    Nakashima, T.
    Okumura, T.
    Nagata, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E168 - E169
  • [33] Optimisation of the Transmitter Layout in a VLP System Using an Aperture-Based Receiver
    Menendez, Jose Miguel
    Steendam, Heidi
    PHOTONICS, 2024, 11 (06)
  • [34] Localized and propagating surface plasmon resonances in aperture-based third harmonic generation
    Nezami, Mohammadreza S.
    Gordon, Reuven
    OPTICS EXPRESS, 2015, 23 (25): : 32006 - 32014
  • [35] Additively Manufactured Coatings
    Kumar, Pankaj
    Menezes, Pradeep L.
    COATINGS, 2021, 11 (05)
  • [36] Optimization of photon beam energy in aperture-based intensity modulated radiation therapy
    St-Hilaire, J.
    Sevigny, C.
    Beaulieu, F.
    Germain, F.
    Tremblay, D.
    Beaulieu, L.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S54 - S54
  • [37] HIGH PRECISION DISCRETIZATION MODEL FOR CODED APERTURE-BASED COMPRESSIVE SPECTRAL IMAGING
    Arguello, Henry
    Rueda, Hoover F.
    Arce, Gonzalo R.
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 1919 - 1922
  • [38] Impact of different dose calculation algorithms on aperture-based complexity metric evaluations
    Back, A.
    Larsson, A.
    Gotstedt, J.
    Hauer, A. K.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S741 - S742
  • [39] Aperture-based IMPT as an alternative to Gamma Knife in the treatment of multiple brain metastases
    Gray, T.
    Kolano, A.
    Farr, J.
    Liu, C.
    Donaghue, J.
    Suh, J.
    Xia, P.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1713 - S1715
  • [40] Relationship of segment area and monitor unit efficiency in aperture-based IMRT optimization
    Qi, Peng
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03): : 232 - 243