Simulation of the cool-down process for the ESS cryogenic moderator system

被引:0
|
作者
Tatsumoto, H. [1 ]
Horvath, A. [1 ]
Arnold, P. [1 ]
Boros, M. [1 ]
机构
[1] European Spallat Source ESS ERIC, Partikelgatan 2, Lund, Sweden
关键词
D O I
10.1088/1757-899X/1301/1/012086
中图分类号
O414.1 [热力学];
学科分类号
摘要
The ESS cryogenic Moderator System (CMS) has been designed to supply a subcooled liquid hydrogen (17.5 K and 1.0 MPa) to two hydrogen moderators where the nuclear heating is estimated to be 6.7 kW (to be increased to four in the future). The CMS is cooled by a helium refrigerator system with a cooling power of 30.3 kW at 15 K. In this study, a one-dimensional simulation code has been developed to understand temperature behaviors during the cool-down process. The operational methods and parameters have been optimized. The CMS cool-down process is divided into three phases (I: gaseous hydrogen above 36 K, II: condensation from 36 to 31 K, and III: liquid hydrogen below 31 K). It turns out from the simulation result that the CMS would be able to be cooled down to the nominal condition of 17 K within 27 hours.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Design of a fast cool-down IRFPA image guidance system
    Mu Hong-Shan
    Chen Jing
    Qiao Yu-Hua
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2016, 35 (03) : 310 - 316
  • [22] Heat transfer in large bins during the apples cool-down process
    Hoffmann, Tuany Gabriela
    Linke, Manfred
    Praeger, Ulrike
    Sonawane, Akshay D.
    Buechele, Felix
    Neuwald, Daniel Alexandre
    Jedermann, Reiner
    Sturm, Barbara
    Mahajan, Pramod, V
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 170 : 60 - 69
  • [23] OPTIMAL COOL-DOWN IN LINEAR VISCOELASTICITY
    WEITSMAN, Y
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1980, 47 (01): : 35 - 39
  • [24] Transient thermodynamic behavior of cryogenic mixed fluid thermosiphon and its cool-down time estimation
    Lee, Jisung
    Kim, Youngkwon
    Jeong, Sangkwon
    CRYOGENICS, 2010, 50 (05) : 352 - 358
  • [25] Cryostat Suspension System Analysis During Cool-Down and its Validation
    Saha S.
    Gupta A.D.
    Ahammed M.
    Journal of The Institution of Engineers (India): Series C, 2017, 98 (2) : 179 - 184
  • [26] The Value of Warm-Up and Cool-Down
    Bushman, Barbara A.
    ACSMS HEALTH & FITNESS JOURNAL, 2024, 28 (02) : 6 - 9
  • [27] COOL-DOWN CAN SAVE YOUR LIFE
    不详
    SCIENCE DIGEST, 1984, 92 (05) : 18 - 18
  • [28] Cool-Down Processes of the NICA Accelerator Complex
    Mitrofanova, Y.
    Emelianov, N.
    Nikiforov, D.
    12TH CRYOGENICS 2012 IIR INTERNATIONAL CONFERENCE, 2012, : 357 - 362
  • [29] Cool-down test of HWR cryomodule for RAON
    Kim, Y.
    Lee, M.
    Jo, Y. W.
    Choi, J. W.
    Kim, H.
    Kim, W. K.
    Kim, H. J.
    PROGRESS IN SUPERCONDUCTIVITY AND CRYOGENICS, 2015, 17 (04): : 43 - 46
  • [30] Optimal control of forced cool-down processes
    Badescu, V
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (3-4) : 741 - 748