Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis

被引:1
|
作者
Singh, Sanidhya [1 ]
Bennett, Miles Romney [2 ]
Chen, Chen [2 ]
Shin, Sooyoon [2 ]
Ghanbari, Hamid [1 ]
Nelson, Benjamin W. [2 ,3 ]
机构
[1] Univ Michigan, Med Sch, 1301 Catherine St, Ann Arbor, MI 48109 USA
[2] Verily Life Sci LLC, South San Francisco, CA USA
[3] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Psychiat, Div Digital Psychiat, Boston, MA USA
关键词
photoplethysmography; pulse oximetry; arterial blood gas; skin tone; skin pigmentation; bias; digital technology; RELIABILITY; SATURATION; EXERCISE;
D O I
10.2196/62769
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background:Photoplethysmography (PPG) is a technology routinely used in clinical practice to assess blood oxygenation (SpO(2)) and pulse rate (PR). Skin pigmentation may influence accuracy, leading to health outcomes disparities. Objective:This systematic review and meta-analysis primarily aimed to evaluate the accuracy of PPG-derived SpO(2) and PR by skin pigmentation. Secondarily, we aimed to evaluate statistical biases and the clinical relevance of PPG-derived SpO(2) and PR according to skin pigmentation. Methods:We identified 23 pulse oximetry studies (n=59,684; 197,353 paired SpO(2)-arterial blood observations) and 4 wearable PR studies (n=176; 140,771 paired PPG-electrocardiography observations). We evaluated accuracy according to skin pigmentation group by comparing SpO(2) accuracy root-mean-square values to the regulatory threshold of 3% and PR 95% limits of agreement values to +5 or -5 beats per minute (bpm), according to the standards of the American National Standards Institute, Association for the Advancement of Medical Instrumentation, and the International Electrotechnical Commission. We evaluated biases and clinical relevance using mean bias and 95% CI. Results:For SpO(2), accuracy root-mean-square values were 3.96%, 4.71%, and 4.15%, and pooled mean biases were 0.70% (95% CI 0.17%-1.22%), 0.27% (95% CI -0.64% to 1.19%), and 1.27% (95% CI 0.58%-1.95%) for light, medium, and dark pigmentation, respectively. For PR, 95% limits of agreement values were from -16.02 to 13.54, from -18.62 to 16.84, and from -33.69 to 32.54, and pooled mean biases were -1.24 (95% CI -5.31 to 2.83) bpm, -0.89 (95% CI -3.70 to 1.93) bpm, and -0.57 (95% CI -9.44 to 8.29) bpm for light, medium, and dark pigmentation, respectively. Conclusions:SpO(2) and PR measurements may be inaccurate across all skin pigmentation groups, breaching U.S. Food and Drug Administration guidance and industry standard thresholds. Pulse oximeters significantly overestimate SpO(2) for both light and dark skin pigmentation, but this overestimation may not be clinically relevant. PRs obtained from wearables exhibit no statistically or clinically significant bias based on skin pigmentation.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Diagnostic accuracy for skin cancers: a systematic review and meta-analysis
    Chen, Jennifer
    Fernandez, Kristen
    Reddy, Rasika
    Fadadu, Raj
    Kohn, Michael
    Kim, Mi-Ok
    Wei, Maria
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2023, 89 (03) : AB148 - AB148
  • [22] Changes in Oxygenation Levels During Moderate Altitude Simulation (Hypoxia-Induced): A Pilot Study Investigating the Impact of Skin Pigmentation in Pulse Oximetry
    Ochoa-Gutierrez, Victor
    Guerrero-Zuniga, Selene
    Reboud, Julien
    Pazmino-Betancourth, Mauro
    Harvey, Andrew R.
    Cooper, Jonathan M.
    OXYGEN TRANSPORT TO TISSUE XLIII, 2022, 1395 : 391 - 396
  • [23] The safety of pulse corticosteroid therapy-Systematic review and meta-analysis
    Edel, Yonatan
    Avni, Tomer
    Shepshelovich, Daniel
    Reich, Shelley
    Rozen-Zvi, Benaya
    Elbaz, Michal
    Leibovici, Leonard
    Molad, Yair
    Gafter-Gvili, Anat
    SEMINARS IN ARTHRITIS AND RHEUMATISM, 2020, 50 (03) : 534 - 545
  • [24] Pulse pressure as an independent predictor of stroke: a systematic review and a meta-analysis
    Feng-Di Liu
    Xiao-Lei Shen
    Rong Zhao
    Xiao-Xiao Tao
    Shuo Wang
    Jia-Jun Zhou
    Bo Zheng
    Qi-Ting Zhang
    Qian Yao
    Ying Zhao
    Xin Zhang
    Xue-Mei Wang
    Hui-Qin Liu
    Liang Shu
    Jian-Ren Liu
    Clinical Research in Cardiology, 2016, 105 : 677 - 686
  • [25] Continuous automatic pulse pressure variation: a systematic review and meta-analysis
    Bang, Heeyoung
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2015, 58 (06): : 563 - 568
  • [26] Pulse pressure as an independent predictor of stroke: a systematic review and a meta-analysis
    Liu, Feng-Di
    Shen, Xiao-Lei
    Zhao, Rong
    Tao, Xiao-Xiao
    Wang, Shuo
    Zhou, Jia-Jun
    Zheng, Bo
    Zhang, Qi-Ting
    Yao, Qian
    Zhao, Ying
    Zhang, Xin
    Wang, Xue-Mei
    Liu, Hui-Qin
    Shu, Liang
    Liu, Jian-Ren
    CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (08) : 677 - 686
  • [27] Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
    Jensen, LA
    Onyskiw, JE
    Prasad, NGN
    HEART & LUNG, 1998, 27 (06): : 387 - 408
  • [28] Accuracy of pulse oximetry in screening for congenital heart disease in asymptomatic newborns: a systematic review
    Thangaratinam, Shakila
    Daniels, Jane
    Ewer, Andrew K.
    Zamora, Javier
    Khan, Khalid S.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2007, 92 (03): : F176 - F180
  • [30] Defining the role of skin pigmentation in the accuracy of pulse oximetry in COVID-19 subjects receiving domiciliary oxygen supplementation
    Jolobe, Oscar M. P.