Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks

被引:1
|
作者
Wakamatsu, Kaien [1 ]
Doi, Kazuya [1 ]
Kobatake, Reiko [1 ]
Oki, Yoshifumi [1 ]
Tsuga, Kazuhiro [1 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Dept Adv Prosthodont, Hiroshima, Japan
来源
CLINICAL AND EXPERIMENTAL DENTAL RESEARCH | 2024年 / 10卷 / 06期
关键词
Bone density; Dental implantation; Dental implants; SITE PREPARATION; CORTICAL THICKNESS; ASSESSMENTS; INSERTION; SURGERY;
D O I
10.1002/cre2.70048
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Bone density is an important factor for long-term implant success. Peri-implant bone density evaluation before implant placement can be useful for treatment planning, such as the selection of proper implant size or drilling protocol in each case. In this study, we aimed to establish an objective intraoperative bone density evaluation method by measuring the drilling torque value using a newly designed density measurement drill. Materials and Methods: Drilling torque value measurement was performed intraoperatively using three types of drills; two previously reported drills and a newly designed drill as a density measurement drill. Polyurethane bone blocks of different densities (D1-D4) were used in this experiment. After the measurement, implants were inserted based on the scheduled plan, and insertion torque (IT) and implant stability quotient (ISQ) were measured to assess primary implant stability. Results: The drilling torque value increased with the bone blocks' density, and there were significant differences among different densities in all groups (p < 0.05). The drilling torque value showed a positive correlation with IT in all groups (p < 0.05). In addition, the drilling torque value increased with the increase in ISQ in all groups. Conclusions: Within the limitations of this study, a newly designed density measurement drill was able to classify D1-D4 in polyurethane bone blocks despite its narrow diameter, and an objective intraoperative bone evaluation can be achieved. An intraoperative assessment of the drilling torque value can predict primary implant stability and provide valuable information for intraoperative treatment planning, such as undersized drilling protocol and implant size change.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, Osseodensification: an in vitro study
    Barbera-Millan, Javier
    Larrazabal-Moron, Carolina
    Jose Eneiso-Ripoll, Juan
    Perez-Pevida, Esteban
    Chavarri-Prado, David
    Dolores Gomez-Adrian, Maria
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2021, 26 (03): : E361 - E367
  • [42] Influence of bone density on implant stability parameters and implant success: A retrospective clinical study
    Turkyilmaz I.
    McGlumphy E.A.
    BMC Oral Health, 8 (1)
  • [43] Does intraoperative bone density testing correlate with parameters of primary implant stability? A pilot study in minipigs
    Grobecker-Karl, Tanja
    Palarie, Victor
    Schneider, Sonja
    Karl, Matthias
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2019, 5 (06): : 594 - 600
  • [44] Comparison Between Cortical Drill and Cortical Tap and Their Influence on Primary Stability of Macro-Thread Tapered Implant in Thin Crestal Cortical Bone and Low-Density Bone
    Heo, Dasom
    Heo, Young-Ku
    Lee, Jong-Ho
    Lee, Jun-Jae
    Kim, Bongju
    IMPLANT DENTISTRY, 2017, 26 (05) : 711 - 717
  • [45] Effects on Ridge Dimensions, Bone Density, and Implant Primary Stability with Osseodensification Approach in Implant Osteotomy Preparation
    Yeh, Yu-Ting
    Chu, Tien-Min G.
    Blanchard, Steven B.
    Hamada, Yusuke
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : 474 - 484
  • [46] Clinical methodologies for achieving primary dental implant stability The effects of alveolar bone density
    Cavallaro, John, Jr.
    Greenstein, Ben
    Greenstein, Gary
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2009, 140 (11): : 1366 - 1372
  • [47] In vitro comparison of primary stability of two implant designs in D3 bone
    Gonzalez-Serrano, Jose
    Ortega-Aranegui, Ricardo
    Lopez-Quiles, Juan
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2017, 22 (04): : E473 - E477
  • [48] An In Vitro Evaluation of Primary Stability Values for Two Differently Designed Implants to Suit Immediate Loading in Very Soft Bone
    Krischik, Dirk
    Tokgoz, Selen Ergin
    van Orten, Andreas
    Friedmann, Anton
    Bilhan, Hakan
    DENTISTRY JOURNAL, 2021, 9 (01)
  • [49] A Novel Osseous Densification Approach in Implant Osteotomy Preparation to Increase Biomechanical Primary Stability, Bone Mineral Density, and Bone-to-Implant Contact
    Huwais, Salah
    Meyer, Eric G.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 27 - 36
  • [50] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: an in-vitro study
    Rismanchian, Mansour
    Afshari, Mojtaba
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2020, 34 (04) : 319 - 333