Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks

被引:1
|
作者
Wakamatsu, Kaien [1 ]
Doi, Kazuya [1 ]
Kobatake, Reiko [1 ]
Oki, Yoshifumi [1 ]
Tsuga, Kazuhiro [1 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Dept Adv Prosthodont, Hiroshima, Japan
来源
关键词
Bone density; Dental implantation; Dental implants; SITE PREPARATION; CORTICAL THICKNESS; ASSESSMENTS; INSERTION; SURGERY;
D O I
10.1002/cre2.70048
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Bone density is an important factor for long-term implant success. Peri-implant bone density evaluation before implant placement can be useful for treatment planning, such as the selection of proper implant size or drilling protocol in each case. In this study, we aimed to establish an objective intraoperative bone density evaluation method by measuring the drilling torque value using a newly designed density measurement drill. Materials and Methods: Drilling torque value measurement was performed intraoperatively using three types of drills; two previously reported drills and a newly designed drill as a density measurement drill. Polyurethane bone blocks of different densities (D1-D4) were used in this experiment. After the measurement, implants were inserted based on the scheduled plan, and insertion torque (IT) and implant stability quotient (ISQ) were measured to assess primary implant stability. Results: The drilling torque value increased with the bone blocks' density, and there were significant differences among different densities in all groups (p < 0.05). The drilling torque value showed a positive correlation with IT in all groups (p < 0.05). In addition, the drilling torque value increased with the increase in ISQ in all groups. Conclusions: Within the limitations of this study, a newly designed density measurement drill was able to classify D1-D4 in polyurethane bone blocks despite its narrow diameter, and an objective intraoperative bone evaluation can be achieved. An intraoperative assessment of the drilling torque value can predict primary implant stability and provide valuable information for intraoperative treatment planning, such as undersized drilling protocol and implant size change.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Bone Density and Implant Primary Stability. A Study on Equine Bone Blocks
    Orlando, Francesco
    Arosio, Federico
    Arosio, Paolo
    Di Stefano, Danilo Alessio
    DENTISTRY JOURNAL, 2019, 7 (03)
  • [2] Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study
    Lee, Jungwon
    Lim, Young-Jun
    Ahn, Jin-Soo
    Kim, Bongju
    Baek, Yeon-Wha
    Lim, Bum-Soon
    PLOS ONE, 2024, 19 (05):
  • [3] Primary Stability Evaluation of a Novel Tapered Implant Inserted in Low-Density Bone Sites: An In Vitro Study
    Degidi, Marco
    Daprile, Giuseppe
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 334 - 337
  • [4] Bone density and primary stability in implant therapy
    Molly, Liene
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 : 124 - 135
  • [5] Influence of bone density and implant drill diameter on the resulting axial force and temperature development in implant burs and artificial bone: an in vitro study
    Möhlhenrich S.C.
    Abouridouane M.
    Heussen N.
    Modabber A.
    Klocke F.
    Hölzle F.
    Oral and Maxillofacial Surgery, 2016, 20 (2) : 135 - 142
  • [6] Relation between bone density and primary implant stability
    Farre-Pages, Nuria
    Auge-Castro, Ma Luisa
    Alaejos-Algarra, Fernando
    Mareque-Bueno, Javier
    Ferres-Padro, Eduard
    Hernandez-Alfaro, Federico
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2011, 16 (01): : E62 - E67
  • [7] The effect of implant length and diameter on primary stability of tilted implant on D4 bone density: An in vitro study
    Baihaqi, Muhammad, I
    Sumarsongko, Taufik
    Bonifacius, Setyawan
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2022, 14 (05): : 487 - 493
  • [8] In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems
    Andres-Garcia, Rodrigo
    Garcia Vives, Nuria
    Herrero Climent, Federico
    Fernandez Palacin, Ana
    Rios Santos, Vicente
    Herrero Climent, Mariano
    Bullon, Pedro
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2009, 14 (02): : E93 - E97
  • [9] Implant primary stability with an osteocondensation drilling protocol in different density polyurethane blocks
    Fanali, Stefano
    Tumedei, Margherita
    Pignatelli, Pamela
    Inchingolo, Francesco
    Pennacchietti, Paolo
    Pace, Gianluca
    Piattelli, Adriano
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (01) : 14 - 20
  • [10] Evaluation of Peri-Implant Crestal Bone Loss with Different Implant Systems, Primary Stability, Bone Density and Soft Tissue Thickness: A Retrospective Study
    Shenoy A.
    Rohinikumar S.
    Maiti S.
    Sivaswamy V.
    Rajaraman V.
    Journal of Long-Term Effects of Medical Implants, 2023, 33 (04) : 53 - 58