ROTOR-STATOR INTERACTION AND VORTEX ROPE IN THE REVERSIBLE PUMP-TURBINE AT OFF-DESIGN CONDITIONS IN TURBINE MODE

被引:0
|
作者
Rode, Bhushan R. [1 ]
Kumar, Arun [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Hydro & Renewable Energy, Roorkee, Uttar Pradesh, India
关键词
pumped storage plant; reversible pump-turbine; rotor-stator interaction; vortex rope; pressure fluctuations; HYDROPOWER; OPERATION;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The reversible pump-turbine (RPT) operates at off-design operating conditions to balance the electricity grid due to the high penetration of variable and intermittent solar and wind energy. During these operating conditions, hydraulic instabilities such as rotor-stator interaction (RSI) and vortex rope in the draft tube give rise to pressure fluctuations in the vaneless space (VS) between the guide vanes and runner, and the draft tube, respectively. Therefore, the RPT may experience fatigue and vibration, further causing the vibration in the local components of the powerhouse. A reduced-scale high-head RPT model, and the SST k-.turbulence model was used to carry out numerical calculations under the present study. The guide vane opening of 10 degrees, 14 degrees, 18.06 degrees (best efficiency point), and 24 degrees were performed and analyzed. The RSI phenomenon occurs in the VS due to the interaction of guide vane and runner. The vortex rope in the draft tube, due to the flow separation in the runner channels, was observed.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Study on cavitating vortex rope characteristics of reversible pump-turbine under part load turbine condition
    Pang, Shujiao
    Zhu, Baoshan
    Shen, Yunde
    Chen, Zhenmu
    PHYSICS OF FLUIDS, 2023, 35 (08)
  • [22] Monitoring of Rotor-Stator Interaction in Pump-Turbine Using Vibrations Measured with On-Board Sensors Rotating with Shaft
    Rodriguez, Cristian G.
    Mateos-Prieto, Borja
    Egusquiza, Eduard
    SHOCK AND VIBRATION, 2014, 2014
  • [23] Numerical simulations of compressor off-design performances with rotor-stator interaction
    School of Power and Energy, Northwestern Polytechnical Univ., Xi'an 710072, China
    Tuijin Jishu, 2006, 5 (422-425+430):
  • [24] High-speed flow visualization in a pump-turbine under off-design operating conditions
    Hasmatuchi, V.
    Roth, S.
    Botero, F.
    Avellan, F.
    Farhat, M.
    25TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2010, 12
  • [25] Proper orthogonal decomposition of turbine rotor-stator interaction
    Cizmas, PGA
    Palacios, A
    JOURNAL OF PROPULSION AND POWER, 2003, 19 (02) : 268 - 281
  • [26] Dynamic Radial Forces and Pressure Fluctuations Measurement at Off-Design Conditions on a Model Scale Pump-Turbine
    Novotny, V.
    Haban, V.
    Skotak, A.
    Loub, R.
    IAHR INTERNATIONAL WORKSHOP ON CAVITATION AND DYNAMIC PROBLEMS IN HYDRAULIC MACHINERY AND SYSTEMS, 2019, 405
  • [27] Optimal design of reversible pump-turbine runner
    Zhu, B. (bszhu@mail.tsinghua.edu.cn), 1600, Chinese Society of Agricultural Engineering (30):
  • [28] Cavitation behavior study in the pump mode of a reversible pump-turbine
    Tao, Ran
    Xiao, Ruofu
    Wang, Fujun
    Liu, Weichao
    RENEWABLE ENERGY, 2018, 125 : 655 - 667
  • [29] Design and development of a Turbine Research Facility to study rotor-stator interaction effects
    Lakshminarayana, B
    Camci, C
    Halliwell, I
    Zaccaria, M
    INTERNATIONAL JOURNAL OF TURBO & JET-ENGINES, 1996, 13 (03) : 155 - 172
  • [30] Predicting the Inception Cavitation of a Reversible Pump-Turbine in Pump Mode
    Tao, Ran
    Xiao, Ruofu
    Zhu, Di
    Liu, Weichao
    9TH INTERNATIONAL SYMPOSIUM ON CAVITATION (CAV2015), 2015, 656