A Comprehensive Review of Performance Metrics for Computer-Aided Detection Systems

被引:0
|
作者
Park, Doohyun [1 ]
机构
[1] Vuno Inc, Seoul 06541, South Korea
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 11期
关键词
performance metric; computer-aided detection; receiver operating characteristic; free-response receiver operating characteristic; alternative free-response receiver operating characteristic; artificial intelligence; lung nodule;
D O I
10.3390/bioengineering11111165
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This paper aims to provide a structured analysis of the performance metrics used in computer-aided detection (CAD) systems, specifically focusing on lung nodule detection in computed tomography (CT) images. By examining key metrics along with their respective strengths and limitations, this study offers guidelines to assist in selecting appropriate metrics. Evaluation methods for CAD systems for lung nodule detection are primarily categorized into per-scan and per-nodule approaches. For per-scan analysis, a key metric is the area under the receiver operating characteristic (ROC) curve (AUROC), which evaluates the ability of the system to distinguish between scans with and without nodules. For per-nodule analysis, the nodule-level sensitivity at fixed false positives per scan is often used, supplemented by the free-response receiver operating characteristic (FROC) curve and the competition performance metric (CPM). However, the CPM does not provide normalized scores because it theoretically ranges from zero to infinity and largely varies depending on the characteristics of the data. To address the advantages and limitations of ROC and FROC curves, an alternative FROC (AFROC) was introduced to combine the strengths of both per-scan and per-nodule analyses. This paper discusses the principles of each metric and their relative strengths, providing insights into their clinical implications and practical utility.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Small pulmonary nodules:: Effect of two computer-aided detection systems on radiologist performance
    Das, Marco
    Muehlenbruch, Georg
    Mahnken, Andreas H.
    Flohr, Thomas G.
    Guendel, Lutz
    Stanzel, Sven
    Kraus, Thomas
    Guenther, Rolf W.
    Wildberger, Joachim E.
    RADIOLOGY, 2006, 241 (02) : 564 - 571
  • [22] Computer-Aided Diagnosis Systems for Automatic Malaria Parasite Detection and Classification: A Systematic Review
    Grignaffini, Flavia
    Simeoni, Patrizio
    Alisi, Anna
    Frezza, Fabrizio
    ELECTRONICS, 2024, 13 (16)
  • [23] VESPER: VISUAL EXPLORATION OF SIMILARITY AND PERFORMANCE METRICS FOR COMPUTER-AIDED DESIGN REPOSITORIES
    Ramanujan, Devarajan
    Bernstein, William Z.
    PROCEEDINGS OF THE ASME 13TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, 2018, VOL 3, 2018,
  • [24] COMPUTER-AIDED DIAGNOSIS - A REVIEW
    SUTTON, GC
    BRITISH JOURNAL OF SURGERY, 1989, 76 (01) : 82 - 85
  • [25] Computer-aided earthmoving systems
    Greene, D.
    Mining Engineering, 1999, 51 (02): : 49 - 52
  • [26] COMPUTER-AIDED INTEGRATED SYSTEMS
    GIBBS, PJ
    CME-CHARTERED MECHANICAL ENGINEER, 1980, 27 (02): : 84 - &
  • [27] Computer-aided detection is here: will computer-aided quality algorithms soon follow?
    McGill, Sarah K.
    ENDOSCOPY, 2022, 54 (08) : 769 - 770
  • [28] COMPUTER-AIDED DESIGN SYSTEMS
    GALLINA, G
    CASABELLA, 1988, 52 (548): : R2 - R8
  • [29] EFFECT OF CASE SELECTION ON THE PERFORMANCE OF COMPUTER-AIDED DETECTION SCHEMES
    NISHIKAWA, RM
    GIGER, ML
    DOI, K
    METZ, CE
    YIN, FF
    VYBORNY, CJ
    SCHMIDT, RA
    MEDICAL PHYSICS, 1994, 21 (02) : 265 - 269
  • [30] Computer-aided detection in musculoskeletal projection radiography: A systematic review
    Gundry, M.
    Knapp, K.
    Meertens, R.
    Meakin, J. R.
    RADIOGRAPHY, 2018, 24 (02) : 165 - 174