Portable, facile microfluidic platform using a low-cost vacuum pump for multiplex biomarker detection in human samples

被引:0
|
作者
Liu, Bo [1 ,2 ,3 ,4 ]
Jin, Jing [2 ]
Ran, Bin [2 ]
Chen, Chaozhan [2 ,5 ]
Li, Jiaqian [1 ]
Han, Jinxiang [3 ,4 ]
Zhu, Yonggang [2 ]
机构
[1] Shandong Univ, Sch Nucl Sci Energy & Power Engn, Jinan 250061, Peoples R China
[2] Harbin Inst Technol, Ctr Microflows & Nanoflows, Sch Mech Engn & Automat, Shenzhen 518055, Peoples R China
[3] Shandong First Med Univ & Shandong Acad Med Sci, Biomed Sci Coll, Jinan 250117, Peoples R China
[4] Shandong First Med Univ & Shandong Acad Med Sci, Shandong Med Biotechnol Ctr, Jinan 250117, Peoples R China
[5] Guangzhou Univ, Sch Mech & Elect Engn, Guangzhou 510006, Peoples R China
来源
关键词
Microfluidics; POCT; Vacuum pump; Multiple biomarkers; Nanocomposites; Electrochemical detection; POINT;
D O I
10.1016/j.snb.2024.136994
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Portable multiplex microfluidic platforms are critically needed for point-of-care testing (POCT) of health-related biomarkers. The complex preparation processes and the use of expensive and bulky devices lead to increased detection costs, hindering the application of emerging POCT technologies. Here, we introduce a portable and versatile microfluidic platform for low-cost multiplex biomarker detection, integrated with a facile and easy-tooperated vacuum pump and mass-produced screen-printed carbon electrodes (SPCEs). The innovative pump, comprising only a syringe, a valve, and a spring, costs approximately $0.50. It operates by using the compressed spring to self-sufficiently drive reagents, which are actuated via a valve switch. The pump's performance was assessed under various conditions, demonstrating consistent operation and a broad pressure range. Additionally, electrocatalytic nanocomposites (Ti3C2Tx/Pt-Pd) were adopted to modify the SPCEs, resulting in high-efficiency performance (<15 min), cost-effectiveness (<$4 per test) and excellent reliability across a broad detection scope. Finally, the platform successfully achieved multiplex detection of biomarkers (glucose, uric acid and lactic acid) in serum, sweat and saliva. This simple and adaptable platform promises to facilitate cost-effective, multiplex biomarker detection, paving the way for large-scale POCT applications, particularly in resource-limited settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Seq-Well: A portable, low-cost platform for massively-parallel single-cell RNA-Seq profiling of sparse clinical samples
    Gierahn, Todd M.
    Wadsworth, Marc H.
    Hughes, Travis K.
    Love, J. Christopher
    Shalek, Alex K.
    JOURNAL OF IMMUNOLOGY, 2017, 198 (01):
  • [42] Facile and Low-Cost Fabrication of a Thread/Paper-Based Wearable System for Simultaneous Detection of Lactate and pH in Human Sweat
    Gang Xiao
    Jing He
    Yan Qiao
    Feng Wang
    Qingyou Xia
    Xin Wang
    Ling Yu
    Zhisong Lu
    Chang-Ming Li
    Advanced Fiber Materials, 2020, 2 : 265 - 278
  • [43] Facile and Low-Cost Fabrication of a Thread/Paper-Based Wearable System for Simultaneous Detection of Lactate and pH in Human Sweat
    Xiao, Gang
    He, Jing
    Qiao, Yan
    Wang, Feng
    Xia, Qingyou
    Wang, Xin
    Yu, Ling
    Lu, Zhisong
    Li, Chang-Ming
    ADVANCED FIBER MATERIALS, 2020, 2 (05) : 265 - 278
  • [44] A suspending-droplet mode paper-based microfluidic platform for low-cost, rapid, and convenient detection of lead(II) ions in liquid solution
    Sun, Han
    Li, Wanbo
    Dong, Zhen-Zhen
    Hu, Chong
    Leung, Chung-Hang
    Ma, Dik-Lung
    Ren, Kangning
    BIOSENSORS & BIOELECTRONICS, 2018, 99 : 361 - 367
  • [45] Human detection by neural networks using a low-cost short-range Doppler radar sensor
    Kwon, Jihoon
    Kwak, Nojun
    2017 IEEE RADAR CONFERENCE (RADARCONF), 2017, : 755 - 760
  • [46] Facile and sensitive chemiluminescence detection of H2O2 and glucose by a gravity/capillary flow and cloth-based low-cost platform
    Li, Huijie
    Wang, Dan
    Liu, Cuiling
    Liu, Rui
    Zhang, Chunsun
    RSC ADVANCES, 2017, 7 (68): : 43245 - 43254
  • [47] A low-cost portable system for on-site detection of soil pH and potassium levels using 3D printed sensors
    Mccole, Matthew
    Bradley, Martin
    Mccaul, Margaret
    Mccrudden, Denis
    RESULTS IN ENGINEERING, 2023, 20
  • [48] Rapid On-Site Detection of SARS-CoV-2 Using RT-LAMP Assay with a Portable Low-Cost Device
    Fu, Quanying
    Pang, Xueyuan
    Su, Zhenning
    Yang, Yuxiao
    Liu, Yiren
    Zhang, Ziyue
    Fu, Yuqiu
    Wang, Jiasi
    Zhou, Jianhua
    BIOSENSORS-BASEL, 2023, 13 (07):
  • [49] A novel approach to low-cost, rapid and simultaneous colorimetric detection of multiple analytes using 3D printed microfluidic channels
    Mishra, Piyush
    Navariya, Sagar
    Gupta, Priyanshi
    Singh, Bhupendra Pratap
    Chopra, Samridhi
    Shrivastava, Swapnil
    Agrawal, Ved Varun
    ROYAL SOCIETY OPEN SCIENCE, 2024, 11 (01):
  • [50] Instant and low-cost detection of urinary microalbumin using smartphone technology and a paper-based platform with a colorimetric ratio analysis
    Nutcha Larpant
    Chanatnan Tetsiri
    Theerasak Rojanarata
    Wanida Laiwattanapaisal
    Scientific Reports, 15 (1)