4D flow cardiac magnetic resonance in pediatric congenital heart disease: Insights from over four years of clinical practice

被引:0
|
作者
Lagerstrand, Kerstin [1 ,2 ]
Svensson, Par-Arne
Andersson, Linnea [1 ,2 ]
Nystrom, Anna
Dangardt, Frida [4 ,5 ]
de Lange, Charlotte [1 ,3 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Queen Silv Childrens Hosp, Dept Pediat Radiol, Gothenburg, Sweden
[4] Univ Gothenburg, Inst Med, Sahlgrenska Acad, Gothenburg, Sweden
[5] Sahlgrens Univ Hosp, Queen Silv Childrens Hosp, Childrens Heart Ctr, Gothenburg, Sweden
关键词
Congenital heart defect; 4D flow CMR; Cardiovascular; Clinical; Flow quantification; Flow visualization; Phase-contrast magnetic resonance imaging; AORTIC REGURGITATION; GUIDELINES;
D O I
10.1016/j.clinimag.2024.110399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Congenital heart diseases (CHDs) are common birth defects. This work presents over four years of clinical experience of 4D flow cardiovascular magnetic resonance (CMR), highlighting its value for pediatric CHD. Methods: Children with various CHD diagnoses (n = 298) were examined on a 1.5 or 3 T scanner using 4D flow CMR in free breathing with respiratory compensation. The image volume was acquired in axial orientation, covering the entire heart and major vessels. Head-to-head comparisons with reference standards were systematically performed. Results: 4D flow CMR provided more detailed insights into complex cardiovascular conditions while maintaining a comparable level of accuracy in peak velocity, Q and Qp/Qs (R = 0.9-1.0) compared to conventional 2D flow CMR. The advantages of 4D flow CMR were particularly evident for valve function, stenosis, and shunt assessments. However, our findings emphasize the need for additional corrections to address partial volume (up to 180 % error in perfusion ratio) and through-plane cardiac motion effects (up to 25/10 ml error in aortic/pulmonary regurgitation volume). Conclusion: Overall, 4D flow CMR proved to be a comprehensive diagnostic tool that enhanced the understanding and management of pediatric CHD, potentially changing the course of the treatment.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Hemodynamic forces from 4D flow magnetic resonance imaging for optimised prediction of cardiac resynchronisation therapy outcome
    Pola, K.
    Roijer, A.
    Borgquist, R.
    Ostenfeld, E.
    Carlsson, M.
    Bakos, Z.
    Arheden, H.
    Arvidsson, P. M.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [42] Fetal hemodynamics and cardiac streaming assessed by 4D flow cardiovascular magnetic resonance in fetal sheep
    Schrauben, Eric M.
    Saini, Brahmdeep Singh
    Darby, Jack R. T.
    Soo, Jia Yin
    Lock, Mitchell C.
    Stirrat, Elaine
    Stortz, Greg
    Sled, John G.
    Morrison, Janna L.
    Seed, Mike
    Macgowan, Christopher K.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (1)
  • [43] Fetal hemodynamics and cardiac streaming assessed by 4D flow cardiovascular magnetic resonance in fetal sheep
    Eric M. Schrauben
    Brahmdeep Singh Saini
    Jack R. T. Darby
    Jia Yin Soo
    Mitchell C. Lock
    Elaine Stirrat
    Greg Stortz
    John G. Sled
    Janna L. Morrison
    Mike Seed
    Christopher K. Macgowan
    Journal of Cardiovascular Magnetic Resonance, 21
  • [44] Regadenoson as a pharmacologic stressor in cardiac magnetic resonance imaging in congenital and acquired pediatric heart disease: initial experience
    Cory V Noel
    Ramkumar Krishnamurthy
    Moffett Brady
    Rajesh Krishnamurthy
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [45] An in vitro validation of cardiac magnetic resonance 4D flow measurements with bioprosthetic mitral valve flow volumes quantification
    Mohamad G Ghosn
    Matthew Jackson
    Dimitrios Maragiannis
    Karen Chin
    Kyle Autry
    Stephen Igo
    Stephen H Little
    Dipan J Shah
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [46] Impact of left atrial appendage occlusion in atrial flow evaluated through 4D flow cardiac magnetic resonance
    Elorza, I. Anduaga
    Ferez, X. Morales
    Guillen, P. Cepas
    Casademunt, P.
    Doltra, A.
    Mill, J.
    Umanzor, E. Flores
    Gea, M. Iriarte
    Sanchis, L.
    Camara, O.
    Freixa, X.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [47] Intracardiac 4D Flow MRI in Congenital Heart Disease: Recommendations on Behalf of the ISMRM Flow & Motion Study Group
    Zhong, Liang
    Schrauben, Eric M.
    Garcia, Julio
    Uribe, Sergio
    Grieve, Stuart M.
    Elbaz, Mohammed S. M.
    Barker, Alex J.
    Geiger, Julia
    Nordmeyer, Sarah
    Marsden, Alison
    Carlsson, Marcus
    Tan, Ru-San
    Garg, Pankaj
    Westenberg, Jos J. M.
    Markl, Michael
    Ebbers, Tino
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (03) : 677 - 681
  • [48] Novel Insights into Complex Cardiovascular Pathologies using 4D Flow Analysis by Cardiovascular Magnetic Resonance Imaging
    Lewandowski, Adam James
    Raman, Betty
    Banerjee, Rajarshi
    Milanesi, Matteo
    CURRENT PHARMACEUTICAL DESIGN, 2017, 23 (22) : 3262 - 3267
  • [49] Machine learning for the automatic assessment of aortic rotational flow and wall shear stress from 4D flow cardiac magnetic resonance imaging
    Garrido-Oliver, Juan
    Aviles, Jordina
    Mejia Cordova, Marcos
    Dux-Santoy, Lydia
    Ruiz-Munoz, Aroa
    Teixido-Tura, Gisela
    Maso Talou, Gonzalo D.
    Morales Ferez, Xabier
    Jimenez, Guillermo
    Evangelista, Arturo
    Ferreira-Gonzalez, Ignacio
    Rodriguez-Palomares, Jose
    Camara, Oscar
    Guala, Andrea
    EUROPEAN RADIOLOGY, 2022, 32 (10) : 7117 - 7127
  • [50] Machine learning for the automatic assessment of aortic rotational flow and wall shear stress from 4D flow cardiac magnetic resonance imaging
    Juan Garrido-Oliver
    Jordina Aviles
    Marcos Mejía Córdova
    Lydia Dux-Santoy
    Aroa Ruiz-Muñoz
    Gisela Teixido-Tura
    Gonzalo D. Maso Talou
    Xabier Morales Ferez
    Guillermo Jiménez
    Arturo Evangelista
    Ignacio Ferreira-González
    Jose Rodriguez-Palomares
    Oscar Camara
    Andrea Guala
    European Radiology, 2022, 32 : 7117 - 7127