Non-Surgical, In-Stent Membrane Bioelectronics for Long-Term Intracranial Pressure Monitoring

被引:0
|
作者
Lee, Jimin [1 ,2 ]
Bateman, Allison [1 ,2 ]
Kim, Mi Hyeon [3 ,4 ]
Rigo, Bruno [2 ,5 ]
Kim, Hodam [1 ,6 ]
Lee, Jaeho [1 ,2 ]
Choi, Yun Hyeok [7 ]
Herbert, Robert [8 ]
Lee, Deok Hee [3 ]
Yeo, Woon-Hong [1 ,2 ,9 ,10 ,11 ]
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wearable Intelligent Syst & Healthcare Ctr, Inst Matter & Syst, Atlanta, GA 30332 USA
[3] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Dept Radiol,Coll Med, 88 Olymp Ro,43 Gil, Seoul 05505, South Korea
[4] Asan Med Ctr, Asan Inst Life Sci, Biomed Engn Res Ctr, 88 Olymp Ro,43 Gil, Seoul 05505, South Korea
[5] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[6] Icahn Sch Med Mt Sinai, Biomed Engn & Imaging Inst, New York, NY 10029 USA
[7] Inje Univ, Haeundae Paik Hosp, 875 Haeun Daero, Busan 48108, South Korea
[8] Louisiana State Univ, Dept Mech & Ind Engn, Baton Rouge, LA 70803 USA
[9] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[10] Emory Univ, Sch Med, Atlanta, GA 30332 USA
[11] Georgia Inst Technol, Parker H Petit Inst Bioengn & Biosci, Atlanta, GA 30332 USA
基金
美国国家科学基金会;
关键词
capacitive sensors; endovascular stent; intracranial pressure; minimally invasive; porous pyramidal structure; WIRELESS; SENSOR; MORTALITY;
D O I
10.1002/adhm.202404680
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Traditional intracranial pressure (ICP) monitoring methods, using intraventricular catheters, face significant limitations, including high invasiveness, discrete data, calibration complexities, and drift issues, which hinder long-term and stable monitoring. Here, a non-surgical, in-stent membrane bioelectronic system is presented for continuous and reliable ICP monitoring. This platform integrates a capacitive thin-film sensor with a stent, enabling precise real-time detection of pressure fluctuations directly within the dural venous sinus without requiring skull penetration or frequent recalibration. The sensor demonstrates a high sensitivity of 0.052%/mmHg and a broad, readable pressure range of 3-30 mmHg while maintaining calibration-free and drift-free performance. A series of in vivo studies highlight the system's superior sensitivity, rapid sampling rate, and long-term stability compared to conventional microcatheters. Statistical analyses reveal a strong agreement between the device and clinical reference, underscoring its potential to revolutionize ICP monitoring. These advancements pave the way for broader clinical applications, minimizing complications and improving patient outcomes in neurocritical care.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Long-term monitoring (LTM) for presurgical evaluations differs from LTM in non-surgical epileptology -: operational consequences.
    Hilfiker, P
    Mothersill, IW
    Krämer, G
    EPILEPSIA, 1999, 40 : 10 - 10
  • [42] Long-term outcomes and dynamic changes of in-stent stenosis after Pipeline embolization device treatment of intracranial aneurysms
    Gui, Siming
    Chen, Xiheng
    Wei, Dachao
    Deng, Dingwei
    You, Wei
    Meng, Xiangyu
    Lv, Jian
    Feng, Junqiang
    Tang, Yudi
    Yang, Shu
    Chen, Ting
    Liu, Peng
    Ge, Huijian
    Jin, Hengwei
    Liu, Xinke
    Jiang, Yuhua
    Feng, Wei
    LI, Youxiang
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2023, 15 (12) : 1187 - U18
  • [43] Long-term Follow-up of In-stent Stenosis After Pipeline Flow Diversion Treatment of Intracranial Aneurysms
    John, Seby
    Bain, Mark D.
    Hui, Ferdinand K.
    Hussain, M. Shazam
    Masaryk, Thomas J.
    Rasmussen, Peter A.
    Toth, Gabor
    NEUROSURGERY, 2016, 78 (06) : 862 - 867
  • [44] Long-Term Risk Factors for Intracranial In-Stent Restenosis From a Multicenter Trial of Stenting for Symptomatic Intracranial Artery Stenosis Registry in China
    Guo, Xu
    Ma, Ning
    Gao, Feng
    Mo, Da-Peng
    Luo, Gang
    Miao, Zhong-Rong
    FRONTIERS IN NEUROLOGY, 2021, 11
  • [45] LONG-TERM CONTINUOUS INTRACRANIAL-PRESSURE MONITORING BY MEANS OF A MODIFIED SUBDURAL PRESSURE TRANSDUCER
    RICHARDSON, A
    HIDE, TAH
    EVERSDEN, ID
    LANCET, 1970, 2 (7675): : 687 - +
  • [46] LONG-TERM TREATMENT AND NON-SURGICAL CORRECTION OF VESICOURETERAL REFLUX IN SPINA-BIFIDA
    TIMMERMANS, L
    JOURNAL D UROLOGIE ET DE NEPHROLOGIE, 1977, 83 : 589 - 592
  • [47] Surgical versus non-surgical treatment of calcaneal fractures in children: A long-term results comparative study
    Ceccarelli, F
    Faldini, C
    Piras, F
    Giannini, S
    FOOT & ANKLE INTERNATIONAL, 2000, 21 (10) : 825 - 832
  • [48] Long-term assessment of periodontal disease progression after surgical or non-surgical treatment: a systematic review
    Sanz-Martin, Ignacio
    Cha, Jae-Kook
    Yoon, Sung-Wook
    Sanz-Sanchez, Ignacio
    Jung, Ui-Won
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2019, 49 (02): : 60 - 75
  • [49] THE EFFECTIVENESS OF LONG-TERM AZITHROMYCIN USING IN NON-SURGICAL THERAPY OF GENERALIZED CHRONIC PERIODONTITIS
    Nepokupna-Slobodyanyuk, T. S.
    WORLD OF MEDICINE AND BIOLOGY, 2014, 43 (01): : 66 - 70
  • [50] Treatment of in-stent restenosis with sirolimus-eluting stent:: Long-term clinical outcome
    Sheiban, Imad
    Chiribiri, Amedeo
    Beninati, Serena
    Moretti, Claudio
    Omede, Pierluigi
    Sciuto, Filippo
    Meliga, Emauele
    Grossomarra, Walter
    Trevi, Giampaolo
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 154M - 155M