Evaluating Effect of Microsoft HoloLens on Extraneous Cognitive Load During Simulated Cervical Lateral Mass Screw Placement

被引:2
|
作者
Babichenko, Dmitriy [1 ]
Andrews, Edward G. [2 ]
Canton, Stephen P. [1 ]
Littleton, Eliza Beth [1 ]
Patel, Ravi [1 ]
Labaze, Dukens [2 ]
Mills, Andrew [1 ]
机构
[1] Univ Pittsburgh, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Med Ctr, Pittsburgh, PA 15260 USA
关键词
Augmented reality; Mixed reality; Microsoft HoloLens; Surgical training; Intraoperative navigation; Extraneous cognitive load; AUGMENTED REALITY; SURGERY;
D O I
10.1007/978-981-19-1607-6_17
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The use of augmented reality (AR) is widely accepted as a feasible training, planning, and prototyping tool. Unlike virtual reality (VR), which implies a complete immersion in a virtual world, AR adds digital elements to a live view by using a headset or camera on a smartphone. The ability to project digital elements into the physical world, combined with the Federal Food and Drug Administration (FDA) approval to use the Microsoft HoloLens in surgical procedures, presents a unique opportunity to explore and develop novel neurosurgical and orthopedic surgery training applications of AR, specifically in spine surgery. The potential of AR in spine surgery training lies in its ability to project CT-generated 3D models of the simulated patient's bony anatomy with overlaid pre-planned screw trajectories, thus allowing learners to practice with real-time guidance. As AR technologies become more mature, numerous research studies have identified AR's potential detriments to learning, including distraction and increased extraneous cognitive load. In this paper, we present our work on evaluating the effect of the presence of a Microsoft HoloLens 1 AR headset on extraneous cognitive load and on task performance during a simulated surgical procedure. A matched crossover trial design was used in which a combined group of 22 neurosurgery and orthopedic surgery residents, ranging in their training from the second postgraduate year (PGY-2) to chief resident (PGY-7 for neurosurgery and PGY-5 for orthopedic surgery, respectively. Participants were asked to place cervical lateral mass screws in a standardized, 3D-printed cervical spine with and without the Microsoft HoloLens 1 headset worn. Lateral mass screws were placed bilaterally at C4 to C6, with six cervical lateral mass screws placed by each participant in each trial, totaling 12 total screws placed. Overall time to drill six pilot holes, time for placement of each individual screw, pilot hole proximity to a predetermined entry point as defined by the Magerl method, and the presence of medial/lateral breaches were assessed and used as surrogate measures of mental taxation. The SURG-TLX questionnaire, a validated measure of extraneous cognitive load, was also used to compare cognitive strain of the task with and without the HoloLens 1.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 24 条
  • [21] Does Transection of the C2 Nerve Roots During C1 Lateral Mass Screw Placement for Atlantoaxial Fixation Result in a Superior Outcome?
    Badhiwala, Jetan H.
    Nassiri, Farshad
    Witiw, Christopher D.
    Mansouri, Alireza
    Almenawer, Saleh A.
    Fehlings, Michael G.
    SPINE, 2017, 42 (18) : E1067 - E1076
  • [22] Accuracy of Lateral Mass Screw Insertion during Cervical Spine Surgery without Fluoroscopic Guidance and Comparison of Postoperative Screw Loosening Rate among Unicortical and Bicortical Screws Using Computed Tomography
    Inoue, Daisuke
    Shigematsu, Hideki
    Matsumori, Hiroaki
    Ueda, Yurito
    Tanaka, Yasuhito
    SPINE SURGERY AND RELATED RESEARCH, 2022, 6 (06): : 625 - 630
  • [23] Relationship between cervical curvature and spinal cord drift distance after laminectomy via lateral mass screw fixation and its effect on clinical efficacy
    Liu, Yong
    Zhou, Xiao-Zhe
    Li, Ning
    Xu, Tong-Guang
    MEDICINE, 2021, 100 (36) : E26220
  • [24] Accuracy and Safety in Screw Placement in the High Cervical Spine Retrospective Analysis of O-arm-based Navigation-assisted C1 Lateral Mass and C2 Pedicle Screws
    Hur, Jung-Woo
    Kim, Jin-Sung
    Ryu, Kyeong-Sik
    Shin, Myeong-Hoon
    CLINICAL SPINE SURGERY, 2019, 32 (04): : E193 - E199