A simple approach for on-site fabrication of copper-based paper device: Disposable electrochemical sensor for the estimation of lead

被引:0
|
作者
Rashmi, M. [1 ,2 ]
Devaramani, Samrat [1 ,2 ]
Ma, Xiaofang [3 ]
机构
[1] RV Inst Technol & Management, Dept Chem, Bengaluru 560076, India
[2] Visvesvaraya Technol Univ, Belagavi 590018, India
[3] Lanzhou City Univ, Sch Chem Engn, Lanzhou 730070, Gansu, Peoples R China
关键词
Copper electrodes; Conducting tape; Fabrication of PES device; Lead; Water samples; ANODIC-STRIPPING VOLTAMMETRY; HEAVY-METALS; BISMUTH; COMPOSITE; CADMIUM; MERCURY; CD(II); ELECTRODES; DESIGN; ZN(II);
D O I
10.1016/j.microc.2024.112456
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
In this study, we are reporting a first of its kind fabrication strategy for paper-based electrochemical device that do not require sophisticated printing setup, or software, and need not to prepare ink and draw electrodes. Inexpensive adhesive copper electrode is used instead of expensive gold, platinum, carbon, or silver electrodes. In a completely new approach, copper conducting tape was exploited to fabricate electrodes onto desired paper substrate. On-site fabrication of the copper-based paper device can be done in two simple steps. First, just by cutting the paper and conducting tape to the required shape and dimensions. Then, taking off the protective layer from the cut conducting tapes and sticking onto the piece of paper in a particular order. Paper based electrochemical sensing (PES) device fabricated using copper conducting tape was efficient enough to detect Pb(II) ions in a liner range 1 mg L-1 to 10 mg L-1. Analytical figures of merit such as coefficient of determination (R2), LOD, and LOQ were investigated and were found to be 0.985, 0.927 mg L-1, and 2.808 mg L-1 respectively. The competency of the proposed fabrication strategy and device thereof was thoroughly examined by studying the applicability of the PES device for the detection of Pb(II) ions in real water samples. The recovery percentage of the analyzed water sample was nearly 100. It was evident from the results that the proposed strategy and the fabricated PES device using copper conducting tape can be extended for point of care testing of Pb(II) ions.
引用
收藏
页数:7
相关论文
共 18 条
  • [1] Determination of Lead with a Copper-Based Electrochemical Sensor
    Kang, Wenjing
    Pei, Xing
    Rusinek, Cory A.
    Bange, Adam
    Haynes, Erin N.
    Heineman, William R.
    Papautsky, Ian
    ANALYTICAL CHEMISTRY, 2017, 89 (06) : 3345 - 3352
  • [2] Disposable Copper-Based Electrochemical Sensor for Anodic Stripping Voltammetry
    Pei, Xing
    Kang, Wenjing
    Yue, Wei
    Bange, Adam
    Heineman, William R.
    Papautsky, Ian
    ANALYTICAL CHEMISTRY, 2014, 86 (10) : 4893 - 4900
  • [3] Disposable Microfluidic Paper-Based Device for On-Site Quantification of Urinary Creatinine
    Melo, Maria M. P.
    Machado, Ana
    Rangel, Antonio O. S. S.
    Mesquita, Raquel B. R.
    CHEMOSENSORS, 2023, 11 (07)
  • [4] Paper-based electrochemical sensor for on-site detection of the sulphur mustard
    Colozza, Noemi
    Kehe, Kai
    Popp, Tanja
    Steinritz, Dirk
    Moscone, Danila
    Arduini, Fabiana
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (20) : 25069 - 25080
  • [5] Paper-based electrochemical sensor for on-site detection of the sulphur mustard
    Noemi Colozza
    Kai Kehe
    Tanja Popp
    Dirk Steinritz
    Danila Moscone
    Fabiana Arduini
    Environmental Science and Pollution Research, 2021, 28 : 25069 - 25080
  • [6] A thiol and magnetic polymer-based electrochemical sensor for on-site simultaneous detection of lead and copper in water
    Wang, Lilian
    Jiang, Xue
    Su, Sha
    Rao, Jiantao
    Ren, Zixuan
    Lei, Ting
    Bai, Huiping
    Wang, Shixiong
    MICROCHEMICAL JOURNAL, 2021, 168
  • [7] On-site measurement cadmium and lead in soil using a disposable bismuth/ionic liquid modified electrochemical sensor
    College of Computer Science and Technology, Shandong University of Technology, ZiBo
    255049, China
    不详
    100083, China
    Int Agric Eng J, 3 (127-134):
  • [8] Portable Copper-Based Electrochemical SERS Sensor for Point-of-Care Testing of Paraquat and Diquat by On-Site Electrostatic Preconcentration
    Li, Shilin
    Ling, Yunhan
    Chen, Jianyue
    Yuan, Xiaoming
    Zhang, Zhengjun
    LANGMUIR, 2024, 40 (30) : 15677 - 15687
  • [9] Nonenzymatic Electrochemical Sensor Device for On-Site Nitrate Determination Using Copper Anchored Magnetite Nanocomposites
    Mukherjee, Priyanka
    Mandal, Mukti
    Mukherjee, Bimalendu
    Dutta, Gorachand
    LANGMUIR, 2025, 41 (10) : 6747 - 6758
  • [10] A simple and rapid approach for on-site analysis of nicotine in tobacco based on a screen-printed electrode as an electrochemical sensor
    Sha, Yunfei
    Yu, Jie
    Xiong, Junwei
    Yu, Chaofan
    Zhu, Xiaoyu
    Zhang, Bingqian
    Fei, Ting
    Wu, Da
    ANALYTICAL METHODS, 2022, 14 (16) : 1579 - 1584