Portable Copper-Based Electrochemical SERS Sensor for Point-of-Care Testing of Paraquat and Diquat by On-Site Electrostatic Preconcentration

被引:0
|
作者
Li, Shilin [1 ]
Ling, Yunhan [1 ]
Chen, Jianyue [2 ]
Yuan, Xiaoming [3 ]
Zhang, Zhengjun [1 ]
机构
[1] Tsinghua Univ, Sch Mat Sci & Engn, Lab Adv Mat, Beijing 100084, Peoples R China
[2] Inst New Funct Mat Co Ltd, Guangxi Inst Ind Technol, Nanning 530200, Peoples R China
[3] China Univ Geosci, Sch Sci, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
SILVER NANOPARTICLES; NANOPOROUS COPPER; RAPID DETECTION; RAMAN; NANOSTRUCTURES; FABRICATION; ARRAYS; EFFICIENCY; SYSTEM; FILMS;
D O I
10.1021/acs.langmuir.4c01437
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
With the advent of portable Raman spectrometers, the deployment of surface-enhanced Raman spectroscopy (SERS) in point-of-care testing (POCT) has been initiated. Within any analytical framework employing SERS, the acuity and selectivity inherent to the SERS substrate are of paramount importance. In this article, we utilize in situ electrochemical passivation technology to fabricate CuI passivation film, which serves as a flexible copper-based SERS substrate. Furthermore, portable electrochemical SERS (EC-SERS) sensors were prepared by combining this with laser direct writing technology. The detection signal was amplified using electrostatic preconcentration technology, showcasing impressive sensitivity, selectivity, and stability in pesticide detection. The detected concentrations of paraquat and diquat in tea reached as low as 3.36 and 2.43 mu g/kg, respectively. Furthermore, the application of electrostatic preconcentration facilitated selective target molecule aggregation on the SERS sensor, markedly increasing Raman signal strength and enabling single-molecule detection. This research introduces an innovative POCT method for pesticides, promising to advance environmental monitoring's analytical capabilities.
引用
收藏
页码:15677 / 15687
页数:11
相关论文
共 50 条
  • [1] Point-of-care glucose testing: on-site competency assessment
    Tongtoyai, Jaray
    Tientadakul, Panutsaya
    Chinswangwatanakul, Wimol
    Opartkiattikul, Nisarat
    INTERNATIONAL JOURNAL OF HEALTH CARE QUALITY ASSURANCE, 2014, 27 (05) : 373 - +
  • [2] A SERS-based point-of-care testing approach for efficient determination of diquat and paraquat residues using a flexible silver flower-coated melamine sponge
    Hu, Peishan
    Zhang, Xinya
    Zhang, Wei
    Song, Liqun
    Wei, Haiyan
    Xiu, Haidi
    Zhang, Mengping
    Shang, Ming
    Wang, Cuijuan
    FOOD CHEMISTRY, 2024, 454
  • [3] Prospects for the commercialization of chemiluminescence-based point-of-care and on-site testing devices
    Park, Jason Y.
    Kricka, Larry J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (23) : 5631 - 5637
  • [4] Prospects for the commercialization of chemiluminescence-based point-of-care and on-site testing devices
    Jason Y. Park
    Larry J. Kricka
    Analytical and Bioanalytical Chemistry, 2014, 406 : 5631 - 5637
  • [5] A smartphone-based on-site nucleic acid testing platform at point-of-care settings
    Xu, Xiayu
    Wang, Xuemin
    Hu, Jie
    Gong, Yang
    Wang, Lin
    Zhou, Wan
    Li, XiuJun
    Xu, Feng
    ELECTROPHORESIS, 2019, 40 (06) : 914 - 921
  • [6] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [7] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    Biosensors and Bioelectronics, 2021, 168
  • [8] A simple approach for on-site fabrication of copper-based paper device: Disposable electrochemical sensor for the estimation of lead
    Rashmi, M.
    Devaramani, Samrat
    Ma, Xiaofang
    RESUSCITATION, 2025, 206
  • [9] A point-of-care testing platform for on-site identification of genetically modified crops
    Wang, Yangyang
    Yang, Furui
    Fu, Yingyi
    He, Xin
    Tian, Haowei
    Yang, Lili
    Wu, Mengxi
    Cao, Jijuan
    Liu, Junshan
    LAB ON A CHIP, 2024, 24 (10) : 2622 - 2632
  • [10] Portable Surface-Enhanced Raman Scattering Sensor for Rapid Detection of Aniline and Phenol Derivatives by On-Site Electrostatic Preconcentration
    Li, Dan
    Li, Da-Wei
    Fossey, John S.
    Long, Yi-Tao
    ANALYTICAL CHEMISTRY, 2010, 82 (22) : 9299 - 9305