Diagnostic Accuracy of 1H-MRS Using PRESS and MEGA-PRESS Techniques in the Preoperative Grading of Patients With Gliomas

被引:0
|
作者
Brun-Vergara, Maria L. [1 ]
Melkus, Gerd [1 ,2 ]
Chakraborty, Santanu [1 ]
Zakhari, Nader [1 ]
Torres, Carlos [1 ]
Alkherayf, Fahad [3 ]
Ghantous, Leya [4 ]
Thornhill, Rebecca [1 ]
Woulfe, John [5 ]
Jansen, Gerard H. [5 ]
Nguyen, Thanh B. [1 ]
机构
[1] Univ Ottawa, Ottawa Hosp, Dept Radiol Radiat Oncol & Med Phys, Ottawa, ON, Canada
[2] Carleton Univ, Dept Phys, Ottawa, ON, Canada
[3] Univ Ottawa, Ottawa Hosp, Div Neurosurg, Ottawa, ON, Canada
[4] Univ Sherbrooke, Fac Med, Sherbrooke, PQ, Canada
[5] Univ Ottawa, Dept Pathol & Lab Med, Eastern Ontario Reg Labs Assoc, Ottawa, ON, Canada
关键词
metabolites; isocitrate dehydrogenase; MR spectroscopy; MEGA-PRESS; gliomas; MAGNETIC-RESONANCE-SPECTROSCOPY; MR SPECTROSCOPY; TUMORS; BRAIN;
D O I
10.1002/jmri.29690
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundEdited MRS technique such as MEshcher-GArwood Point RESolved Spectroscopy (MEGA-PRESS) can determine isocitrate dehydrogenase mutation (IDH) mutation status in patients with gliomas but its accuracy in assessing glioma grade has not yet been formally evaluated. PurposeTo evaluate the diagnostic accuracy of metabolites such as lactate obtained from the PRESS and MEGA-PRESS sequences in the preoperative grading of glioma. To assess the prognostic value of those metabolite ratios in the overall survival of patients with gliomas. Study TypeProspective. SubjectsSixty-nine subjects with gliomas (16 grade 2, 21 grade 3, and 32 grade 4). Mean age was 50.5 +/- 16.7 years; 38 were male and 31 were female. Field Strength/Sequence3 T/MEGA-PRESS, PRESS. AssessmentSingle voxel PRESS and MEGA-PRESS spectra were obtained from tumors in patients undergoing preoperative MRI. Several tumor metabolites were measured from the PRESS, MEGA-PRESS edit-off, and difference spectra using LCModel (Linear Combination of Model Spectra) software. Diagnosis and glioma grading was done using the World Health Organization (WHO) 2016 classification. Overall survival was assessed. Statistical TestsDiagnostic accuracy was measured using receiver-operating characteristic (ROC) curve. Univariate and multivariate Cox proportional hazards modeling was used for the assessment of prognostic factors for time to death. ResultsIn the differentiation between low- vs. high-grade gliomas, tCr/tCho ratios obtained from PRESS and MEGA-PRESS sequences had similar accuracies (area under the ROC curves [AUCs] = 0.71) while Lac/NAA from PRESS had a lower accuracy (AUC = 0.65). The presence of a detectable 2-hydroxyglutarate peak on the difference spectrum was a favorable prognostic factor in univariate analysis (hazard ratio = 0.25, 95% confidence interval: 0.08-0.83). No other metabolite was found to be a significant prognostic factor in univariate and multivariate analyses. Data ConclusionEdited MRS can be used to detect metabolites which can help in the preoperative grading of gliomas and in determination of the overall survival. A separate PRESS acquisition is needed for lactate quantification. Plain Language SummaryGliomas are brain tumors that vary in severity. This study explored the use of two advanced MR spectroscopy techniques (PRESS and MEGA-PRESS) in detecting tumor metabolites. The authors found that both techniques' choline/creatine ratio showed moderate accuracy in identifying high-grade gliomas. Lactate was better revealed with the PRESS technique and was associated with high-grade gliomas. They confirmed that the MEGA-PRESS technique allowed additional detection of 2-hydroxyglutarate in IDH-mutant gliomas, which was linked to better survival. These findings emphasize that advanced MR spectroscopy can extract metabolic information time-efficiently, which can be used to improve the preoperative diagnosis of patients with gliomas. Level of Evidence1 Technical EfficacyStage 2
引用
收藏
页数:9
相关论文
共 29 条
  • [1] Measuring Cerebral and Cerebellar Glutathione in Children Using 1H MEGA-PRESS MRS
    Raschke, F.
    Noeske, R.
    Dineen, R. A.
    Auer, D. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (02) : 375 - 379
  • [2] 1H-MRS and MEGA-PRESS pulse sequence in the study of balance of inhibitory and excitatory neurotransmitters in the human brain of ultra-high risk of schizophrenia patients
    Menschikov, P. E.
    Semenova, N. A.
    Ublinskiy, M. V.
    Akhadov, T. A.
    Keshishyan, R. A.
    Lebedeva, I. S.
    Omelchenko, M. A.
    Kaleda, V. G.
    Varfolomeev, S. D.
    DOKLADY BIOCHEMISTRY AND BIOPHYSICS, 2016, 468 (01) : 168 - 172
  • [3] 1H-MRS and MEGA-PRESS pulse sequence in the study of balance of inhibitory and excitatory neurotransmitters in the human brain of ultra-high risk of schizophrenia patients
    P. E. Menschikov
    N. A. Semenova
    M. V. Ublinskiy
    T. A. Akhadov
    R. A. Keshishyan
    I. S. Lebedeva
    M. A. Omelchenko
    V. G. Kaleda
    S. D. Varfolomeev
    Doklady Biochemistry and Biophysics, 2016, 468 : 168 - 172
  • [4] Examining alterations in GABA concentrations in the basal ganglia of patients with Parkinson’s disease using MEGA-PRESS MRS
    Elsadig E. A. Elmaki
    Tao Gong
    D. Menene Nkonika
    Guangbin Wang
    Japanese Journal of Radiology, 2018, 36 : 194 - 199
  • [5] Examining alterations in GABA concentrations in the basal ganglia of patients with Parkinson's disease using MEGA-PRESS MRS
    Elmaki, Elsadig E. A.
    Gong, Tao
    Nkonika, D. Menene
    Wang, Guangbin
    JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (03) : 194 - 199
  • [6] Investigation of NAA and NAAG dynamics underlying visual stimulation using MEGA-PRESS in a functional MRS experiment
    Landim, Ricardo C. G.
    Edden, Richard A. E.
    Foerster, Bernd
    Li, Li Min
    Covolan, Roberto J. M.
    Castellano, Gabriela
    MAGNETIC RESONANCE IMAGING, 2016, 34 (03) : 239 - 245
  • [7] Preoperative grading of intracranial meningioma by magnetic resonance spectroscopy (1H-MRS)
    Lin, Meng-Chi
    Li, Chiao-Zhu
    Hsieh, Chih-Chuan
    Hong, Kun-Ting
    Lin, Bon-Jour
    Lin, Chin
    Tsai, Wen-Chiuan
    Lee, Chiao-Hua
    Lee, Man-Gang
    Chung, Tzu-Tsao
    Tang, Chi-Tun
    Ju, Da-Tong
    Ma, Hsin-, I
    Liu, Ming-Ying
    Chen, Yuan-Hao
    Hueng, Dueng-Yuan
    PLOS ONE, 2018, 13 (11):
  • [8] Combined diagnostic value of 11C-methionine PET and 1H-MRS for gliomas
    Zhao, Xiaobin
    Wang, Xin
    Ai, Lin
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [9] Frame-by-frame PRESS 1H-MRS of the brain at 3 T:: The effects of physiological motion
    Katz-Brull, R
    Lenkinski, RE
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 184 - 187
  • [10] Using Machine Learning Techniques to Explore 1H-MRS data of Brain Tumors
    Fernando Gonzalez-Navarro, Felix
    Belanche-Munoz, Lluis A.
    2009 EIGHTH MEXICAN INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE, PROCEEDINGS, 2009, : 134 - 139