Comparison between the International Outcome Inventory for Hearing Aids Questionnaire and Real-Ear Measurement

被引:0
|
作者
Nam, Gi-Sung [1 ]
Lee, Young Jae [1 ]
Song, Hansoo [2 ]
Oh, Jeonghyun [1 ]
Cho, Sung Il [1 ]
机构
[1] Chosun Univ, Coll Med, Dept Otolaryngol Head & Neck Surg, Gwangju, South Korea
[2] Chosun Univ, Coll Med, Dept Occupat & Environm Med, Gwangju, South Korea
关键词
Hearing aids; Questionnaires; IOI-HA; Real ear; Hearing loss; ABBREVIATED PROFILE; BENEFIT; PERFORMANCE; PERIOD; SPEECH;
D O I
10.1159/000540738
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Introduction: The international outcome inventory for hearing aids (IOI-HA) is a questionnaire widely used to assess the subjective benefits of hearing aids. This study aimed to evaluate the relationship between IOI-HA outcomes and target mismatch in real-ear measurement (REM). Methods: Thirty-four ears of 25 patients who had worn hearing aids were evaluated using the Korean version of the IOI-HA and REM after fi tting for 2 months. Real-ear insertion gain (REIG) was measured at three different levels of input intensity - 50, 65, and 80 dB sound pressure level (SPL) - and a frequency range of 0.25-6 kHz. Factors 1 and 2 and total IOI-HA scores were compared with the mismatches of REIGs and target gains of REM. Results: Factor 1, factor 2, and total IOI-HA scores were 14.6 +/- 3.5, 11.4 +/- 2.2, and 25.9 +/- 5.1, respectively. The averages of the difference of REIGs and target gains in REM at 50, 65, and 80 dB SPL input levels were - 3.1 +/- 6.7, - 2.3 +/- 7.2, and - 3.0 +/- 8.2, respectively. Factors 1 and 2 scores of the IOI-HA showed significant correlations with target mismatch in REM at 1 kHz and 0.75 kHz frequencies, respectively. Total IOI-HA scores had significant correlations with target mismatches in REM at 0.75 and 1 kHz frequencies. Conclusion: IOI-HA scores correlated with target mismatch in REM at mid frequencies. The IOI-HA can be a useful screening measure for evaluating the necessity of further adjustments in hearing aids through REM at mid frequencies.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 50 条
  • [21] NIDC/VA hearing aid clinical trial and follow-up: Coupler and real-ear measurement
    Peek, Barbara F.
    Rosenfeld, Mia A. L.
    Brattt, Gene W.
    Williams, David W.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2007, 18 (04) : 282 - 291
  • [22] REAL-EAR ATTENUATION OF EARMUFFS IN NORMAL-HEARING AND HEARING-IMPAIRED INDIVIDUALS
    SUTER, AH
    LEMPERT, BL
    FRANKS, JR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (05): : 2114 - 2117
  • [23] International Outcome Inventory for Hearing Aids (IOI-HA) translation into isiXhosa
    Frisby, Caitlin
    Eikelboom, Robert H.
    Mahomed-Asmail, Faheema
    de Kock, Tersia
    Manchaiah, Vinaya
    Swanepoel, De Wet
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2024, 63 (03) : 229 - 232
  • [24] CLINICAL-TRIAL OF IN-THE-EAR HEARING-AIDS - A COMPARISON BETWEEN IN-THE-EAR AND BEHIND-THE-EAR HEARING-AIDS
    JERLVALL, L
    ALMQVIST, B
    OVEGARD, A
    ARLINGER, S
    SCANDINAVIAN AUDIOLOGY, 1983, 12 (01): : 63 - 70
  • [25] Results of Factorial Validity and Reliability of the International Outcome Inventory for Hearing Aids in Turkish
    Serbetcioglu, Bulent
    Mutlu, Basak
    Kirkilm, Gunay
    Uzunoglu, Selim
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2009, 5 (01): : 80 - 86
  • [26] Adaptation of the International Outcome Inventory for Hearing Aids (IOI-HA) in Hindi
    Rachana, Dhananjay
    Rajalakshmi, K.
    EGYPTIAN JOURNAL OF OTOLARYNGOLOGY, 2024, 40 (01):
  • [27] Comparison of real-ear insertion gains in Japanese-speaking individuals wearing hearing aids with DSLv5 and NAL-NL2
    Furuki, Shogo
    Sano, Hajime
    Kurioka, Takaomi
    Ogiwara, Atsuko
    Nakagawa, Takahito
    Inoue, Rie
    Umehara, Sachie
    Hara, Yuki
    Suzuki, Keiko
    Yamashita, Taku
    AURIS NASUS LARYNX, 2021, 48 (01) : 75 - 81
  • [28] International Outcome Inventory for Hearing Aids (IOI-HA): results from The Netherlands
    Kramer, SE
    Goverts, ST
    Dreschler, WA
    Boymans, M
    Festen, JW
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2002, 41 (01) : 36 - 41
  • [29] Development of the speech test signal in Brazilian Portuguese for real-ear measurement
    Garolla, Luciana P.
    Scollie, Susan D.
    Martinelli Iorio, Maria Cecilia
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2013, 52 (08) : 572 - 576
  • [30] MEASUREMENT OF THE REAL-EAR ATTENUATION OF HEARING PROTECTORS ACCORDING TO THE SOUTH-AFRICAN STANDARD SABS-572 1973
    CHILLERY, JA
    JOURNAL OF SOUND AND VIBRATION, 1979, 67 (01) : 21 - 33