Use of continuous glucose monitoring and hybrid closed-loop therapy in pregnancy

被引:1
|
作者
Benhalima, Katrien [1 ,2 ]
Yamamoto, Jennifer M. [3 ,4 ,5 ]
机构
[1] Univ Hosp Leuven, Dept Endocrinol, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Chron Dis & Metab, Clin & Expt Endocrinol, Leuven, Belgium
[3] Univ Manitoba, Dept Internal Med, Winnipeg, MB, Canada
[4] Childrens Hosp Res Inst Manitoba, Winnipeg, MB, Canada
[5] Univ Calgary, Dept Med, Calgary, AB, Canada
关键词
closed-loop therapy; continuous glucose monitoring; gestational diabetes; type; 1; diabetes; 2; GESTATIONAL DIABETES-MELLITUS; GLYCEMIC CONTROL; TYPE-1; WOMEN; OUTCOMES; METRICS; SYSTEM; HYPOGLYCEMIA; MANAGEMENT; ACCEPTABILITY;
D O I
10.1111/dom.15999
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Continuous glucose monitoring (CGM) has led to a paradigm shift in the management of pregnant women with type 1 diabetes (T1D), with improved glycaemic control, less hypoglycaemia and fewer pregnancy complications. Data on CGM use in pregnant women with type 2 diabetes (T2D) are limited. A large randomized controlled trial (RCT) on CGM use in people with T2D in pregnancy is ongoing. Small studies on CGM use in women with gestational diabetes (GDM) have suggested improved glycaemic control and better qualification when insulin is needed. However, none of these studies was powered to evaluate pregnancy outcomes. Several large RCTs are ongoing in women with GDM. In addition to CGM, other technologies, such as advanced hybrid closed-loop (AHCL) systems have further improved glycaemic management in people with T1D. AHCL therapy adapts insulin delivery via a predictive algorithm integrated with CGM and an insulin pump. A large RCT with the AHCL CamAPS (R) FX demonstrated a 10% increase in time in range compared to standard insulin therapy in a pregnant population with T1D. Recently, an RCT of an AHCL system not approved for use in pregnancy (780G MiniMed) has also demonstrated additional benefits of AHCL therapy compared to standard insulin therapy, with improved time in range overnight, less hypoglycaemia and improved treatment satisfaction. More evidence is needed on the impact of AHCL therapy on maternal and neonatal outcomes and on which glycaemic targets with CGM should be used in pregnant women with T2D and GDM. We review the current evidence on the use of CGM and AHCL therapy in pregnancy.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] A Closed-Loop Approach to Continuous Process Scheduling
    Schwindt, Ch.
    Herrmann, S.
    Sagebiel, H.
    2009 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS 1-4, 2009, : 1951 - +
  • [42] Lived Experience of Advanced Hybrid Closed-Loop Versus Hybrid Closed-Loop: Patient-Reported Outcomes and Perspectives
    Hood, Korey K.
    Laffel, Lori M.
    Danne, Thomas
    Nimri, Revital
    Weinzimer, Stuart A.
    Sibayan, Judy
    Bailey, Ryan J.
    Schatz, Desmond
    Bratina, Natasa
    Bello, Rachel
    Punel, Alina
    Calhoun, Peter
    Beck, Roy W.
    Bergenstal, Richard M.
    Phillip, Moshe
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (12) : 857 - 861
  • [43] Continuous drug infusion for diabetes therapy: A closed-loop control system design
    Chen, Jiming
    Cao, Kejie
    Sun, Youxian
    Xiao, Yang
    Su, Xu
    EURASIP JOURNAL ON WIRELESS COMMUNICATIONS AND NETWORKING, 2008, 2008 (1)
  • [44] Continuous Drug Infusion for Diabetes Therapy: A Closed-Loop Control System Design
    Jiming Chen
    Kejie Cao
    Youxian Sun
    Yang Xiao
    Xu(Kevin) Su
    EURASIP Journal on Wireless Communications and Networking, 2008
  • [45] Standardized Hybrid Closed-Loop System Reporting
    Shah, Viral N.
    Garg, Satish K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (05) : 323 - 331
  • [46] A Closed-Loop Dual-Modulation Multi-Spectral Polarimeter for Glucose Monitoring
    Yu, Zhen Fang
    Pirnstill, Casey W.
    Cote, Gerard L.
    OPTICAL DIAGNOSTICS AND SENSING XVI: TOWARD POINT-OF-CARE DIAGNOSTICS, 2016, 9715
  • [47] Closed-loop monitoring for the construction of road tunnels
    Cunha, AP
    NINTH INTERNATIONAL CONGRESS ON ROCK MECHANICS, VOLS 1 & 2, 1999, : 1425 - 1428
  • [48] SAMPLING ERRORS IN CLOSED-LOOP HYBRID SYSTEMS
    ALFORD, CO
    IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1983, 13 (04): : 642 - 647
  • [49] On hybrid systems and closed-loop MPC systems
    Bemporad, A
    Heemels, WPMH
    De Schutter, B
    PROCEEDINGS OF THE 40TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-5, 2001, : 1645 - 1650
  • [50] On hybrid systems and closed-loop MPC systems
    Bemporad, A
    Heemels, WPMH
    De Schutter, B
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2002, 47 (05) : 863 - 869