Capacitively Coupled Electrical Impedance Tomography in Lung Imaging

被引:1
|
作者
Guo, Yuxi [1 ]
Zhu, Liying [2 ]
Wang, Minmin [3 ]
Jiang, Yandan [4 ]
Soleimani, Manuchehr [5 ]
Zhang, Maomao [1 ]
机构
[1] Univ Elect Sci & Technol China, Shenzhen Inst Adv Study, Shenzhen 518071, Peoples R China
[2] City Univ Hong Kong, Dept Biomed Engn, Hong Kong, Peoples R China
[3] Westlake Univ, Westlake Inst Optoelect, Hangzhou 310024, Peoples R China
[4] Zhejiang Univ, Coll Control Sci & Engn, State Key Lab Ind Control Technol, Hangzhou 310027, Peoples R China
[5] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, England
关键词
Impedance; Impedance measurement; Electrodes; Electrical impedance tomography; Monitoring; Lung; Imaging; Capacitively coupled electrical impedance tomography (CCEIT); electrical impedance tomography (EIT); lung imaging;
D O I
10.1109/JSEN.2024.3432991
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical impedance tomography (EIT) has been applied in bedside respiratory monitoring since it is a nonradioactive and noninvasive method. However, adverse effects of direct skin contact limit its usage. This article proposes the application of capacitively coupled EIT (CCEIT) for lung monitoring which avoids the limitation of galvanic contact measurement by using contactless measurements suitable for wearable devices, and it could provide a comfortable and hygienic user experience. This study primarily confirms the feasibility of CCEIT in monitoring respiration through a human body experiment, showing that both magnitude and phase angle of respiratory impedance effectively reflect breathing status. Numerical simulation is conducted to further explore the effects of frequency and insulation layer on CCEIT's impedance measurements and image reconstruction through constructing a digital twin lung model coupling biomechanical and electrical fields as a novel imaging modality. The time-difference imaging based on variations in magnitude and phase angle of impedance is proposed for imaging the respiratory phases of the lungs. CCEIT shows excellent performance in lung monitoring, particularly when operating at high frequencies and with small insulating layer thickness. Utilizing phase angle of impedance yields better imaging outcomes than magnitude, and at a high frequency of 20 MHz, even a 9 mm air gap can still provide satisfactory imaging results. CCEIT has broader applications than EIT, operating over a wide frequency range and utilizing both magnitude and phase angle information of impedance. This makes it promising for more accurate lung image reconstruction and impedance measurements in lung monitoring.
引用
收藏
页码:33072 / 33082
页数:11
相关论文
共 50 条
  • [21] Electrical impedance tomography: functional lung imaging on its way to clinical practice?
    Gong, Bo
    Krueger-Ziolek, Sabine
    Moeller, Knut
    Schullcke, Benjamin
    Zhao, Zhanqi
    EXPERT REVIEW OF RESPIRATORY MEDICINE, 2015, 9 (06) : 721 - 737
  • [22] PRACTICAL FACTORS IN NEONATAL LUNG IMAGING USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    TAKTAK, A
    RECORD, P
    GADD, R
    ROLFE, P
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (02) : 202 - 205
  • [23] Computation of a 3-D Model for Lung Imaging With Electrical Impedance Tomography
    Zhang, Shuai
    Xu, Guizhi
    Zhang, Xueying
    Zhang, Bo
    Wang, Hongbin
    Xu, Yaoyuan
    Yin, Ning
    Li, Ying
    Yan, Weili
    IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (02) : 651 - 654
  • [24] LUNG FUNCTIONAL IMAGING BASED ON MULTI-FREQUENCY ELECTRICAL IMPEDANCE TOMOGRAPHY
    Li, S.
    Shao, X. D.
    Chen, G. D.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2015, 117 : 41 - 41
  • [25] A high-sensitivity four-layer capacitively coupled electrical impedance tomography sensor for brain stroke monitoring
    Li, Weiming
    Zhang, Maomao
    Shi, Yanyan
    Jiang, Yandan
    Soleimani, Manuchehr
    Ji, Haifeng
    Wang, Baoliang
    MEASUREMENT, 2025, 252
  • [26] New Image Reconstruction Algorithm for Capacitively Coupled Electrical Resistance Tomography
    Tan, Wuhao
    Wang, Baoliang
    Huang, Zhiyao
    Ji, Haifeng
    Li, Haiqing
    IEEE SENSORS JOURNAL, 2017, 17 (24) : 8234 - 8241
  • [27] Spectral Capacitively Coupled Electrical Resistivity Tomography for Breast Cancer Detection
    Ma, Gege
    Soleimani, Manuchehr
    IEEE ACCESS, 2020, 8 : 50900 - 50910
  • [28] Sensitivity study of an ultrasound coupled transrectal electrical impedance tomography system for prostate imaging
    Wan, Y.
    Halter, R.
    Borsic, A.
    Manwaring, P.
    Hartov, A.
    Paulsen, K.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (08) : S17 - S29
  • [29] Roles of electrical impedance tomography in lung transplantation
    Jiang, Hui
    Han, Yijiao
    Zheng, Xia
    Fang, Qiang
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [30] MAPPING LUNG MECHANICS BY ELECTRICAL IMPEDANCE TOMOGRAPHY
    Bodenstein, M.
    Boehme, S.
    Bierschock, S.
    Vogt, A.
    Bletz, C.
    Markstaller, K.
    David, M.
    INTENSIVE CARE MEDICINE, 2012, 38 : S42 - S42