Capacitively Coupled Electrical Impedance Tomography in Lung Imaging

被引:1
|
作者
Guo, Yuxi [1 ]
Zhu, Liying [2 ]
Wang, Minmin [3 ]
Jiang, Yandan [4 ]
Soleimani, Manuchehr [5 ]
Zhang, Maomao [1 ]
机构
[1] Univ Elect Sci & Technol China, Shenzhen Inst Adv Study, Shenzhen 518071, Peoples R China
[2] City Univ Hong Kong, Dept Biomed Engn, Hong Kong, Peoples R China
[3] Westlake Univ, Westlake Inst Optoelect, Hangzhou 310024, Peoples R China
[4] Zhejiang Univ, Coll Control Sci & Engn, State Key Lab Ind Control Technol, Hangzhou 310027, Peoples R China
[5] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, England
关键词
Impedance; Impedance measurement; Electrodes; Electrical impedance tomography; Monitoring; Lung; Imaging; Capacitively coupled electrical impedance tomography (CCEIT); electrical impedance tomography (EIT); lung imaging;
D O I
10.1109/JSEN.2024.3432991
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical impedance tomography (EIT) has been applied in bedside respiratory monitoring since it is a nonradioactive and noninvasive method. However, adverse effects of direct skin contact limit its usage. This article proposes the application of capacitively coupled EIT (CCEIT) for lung monitoring which avoids the limitation of galvanic contact measurement by using contactless measurements suitable for wearable devices, and it could provide a comfortable and hygienic user experience. This study primarily confirms the feasibility of CCEIT in monitoring respiration through a human body experiment, showing that both magnitude and phase angle of respiratory impedance effectively reflect breathing status. Numerical simulation is conducted to further explore the effects of frequency and insulation layer on CCEIT's impedance measurements and image reconstruction through constructing a digital twin lung model coupling biomechanical and electrical fields as a novel imaging modality. The time-difference imaging based on variations in magnitude and phase angle of impedance is proposed for imaging the respiratory phases of the lungs. CCEIT shows excellent performance in lung monitoring, particularly when operating at high frequencies and with small insulating layer thickness. Utilizing phase angle of impedance yields better imaging outcomes than magnitude, and at a high frequency of 20 MHz, even a 9 mm air gap can still provide satisfactory imaging results. CCEIT has broader applications than EIT, operating over a wide frequency range and utilizing both magnitude and phase angle information of impedance. This makes it promising for more accurate lung image reconstruction and impedance measurements in lung monitoring.
引用
收藏
页码:33072 / 33082
页数:11
相关论文
共 50 条
  • [1] Capacitively Coupled Electrical Impedance Tomography for Brain Imaging
    Jiang, Y. D.
    Soleimani, M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (09) : 2104 - 2113
  • [2] Study on Dual-Frequency Imaging of Capacitively Coupled Electrical Impedance Tomography: Frequency Optimization
    Jiang, Yandan
    Huang, Junchao
    Ji, Haifeng
    Wang, Baoliang
    Huang, Zhiyao
    Soleirnani, Manuchehr
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [3] A Joint Image Reconstruction Method for Capacitively Coupled Electrical Impedance Tomography
    Wu, Yimin
    Jiang, Yandan
    Ji, Haifeng
    Wang, Baoliang
    Huang, Zhiyao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [4] A new image reconstruction strategy for capacitively coupled electrical impedance tomography
    Wu, Yimin
    Jiang, Yandan
    Ji, Haifeng
    Wang, Baoliang
    Huang, Zhiyao
    Soleimani, Manuchehr
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (03)
  • [5] Study on image reconstruction of capacitively coupled electrical impedance tomography (CCEIT)
    Wang, Yuxin
    Ji, Haifeng
    Huang, Zhiyao
    Wang, Baoliang
    Li, Haiqing
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (09)
  • [6] On the Performance of a Capacitively Coupled Electrical Impedance Tomography Sensor with Different Configurations
    Jiang, Yandan
    He, Xuekai
    Wang, Baoliang
    Huang, Zhiyao
    Soleimani, Manuchehr
    SENSORS, 2020, 20 (20) : 1 - 18
  • [7] ULTRAHIGH IMPEDANCE CAPACITIVELY COUPLED HEART IMAGING ARRAY
    CLIPPINGDALE, AJ
    PRANCE, RJ
    CLARK, TD
    WATKINS, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (01): : 269 - 270
  • [8] Monotonicity-based electrical impedance tomography for lung imaging
    Zhou, Liangdong
    Harrach, Bastian
    Seo, Jin Keun
    INVERSE PROBLEMS, 2018, 34 (04)
  • [9] Feasibility of neonatal lung imaging using electrical impedance tomography
    Taktak, A
    Spencer, A
    Record, P
    Gadd, R
    Rolfe, P
    EARLY HUMAN DEVELOPMENT, 1996, 44 (02) : 131 - 138
  • [10] An Image Reconstruction Method of Capacitively Coupled Electrical Impedance Tomography (CCEIT) Based on DBSCAN and Image Fusion
    He, Xuekai
    Jiang, Yandan
    Wang, Baoliang
    Ji, Haifeng
    Huang, Zhiyao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70