Concurrent validity and test reliability of the deep learning markerless motion capture system during the overhead squat

被引:1
|
作者
Bae, Kyungun [1 ,3 ]
Lee, Seyun [2 ]
Bak, Se-Young [1 ]
Kim, Hyo Sang [1 ]
Ha, Yuncheol [1 ]
You, Joshua H. [3 ]
机构
[1] Naver, Hlth Care Lab, Seongnam 13561, South Korea
[2] NaverCloud, Seongnam 13561, South Korea
[3] Yonsei Univ, Sports Movement Artificial Intelligence Robot Tech, Dept Phys Therapy, Wonju 26493, South Korea
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
基金
新加坡国家研究基金会;
关键词
HUMAN JOINT MOTION; ISB RECOMMENDATION; DEFINITIONS; STROKE; INJURY;
D O I
10.1038/s41598-024-79707-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Marker-based optical motion capture systems have been used as a cardinal vehicle to probe and understand the underpinning mechanism of human posture and movement, but it is time-consuming for complex and delicate data acquisition and analysis, labor-intensive with highly trained operators. To mitigate such inherent issues, we developed an accurate and usable (5-min data collection and processing) deep-learning-based 3-Dimensional markerless motion capture system called "Ergo", designed for use in ecological digital healthcare environments. We investigated the concurrent validity and the test-retest reliability of the Ergo system measurement's whole body joint kinematics (time series joint angles and peak joint angles) data by comparing it with a standard marker-based motion capture system recorded during an overhead squat movement. The Ergo system demonstrated excellent agreement for time series joint angles (R2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$R<^>{2}$$\end{document} = 0.88-0.99) and for peak joint angles (ICC2,1\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ICC_{2,1}$$\end{document} = 0.75-1.0) when compared with the gold standard marker-based motion capture system. Additionally, we observed high test-retest reliability (ICC3,1\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ICC_{3,1}$$\end{document} = 0.92-0.99). In conclusion, the deep learning-based markerless Ergo motion capture system considerably shows comparable performance with the Gold Standard marker-based motion capture system measurements in the concurrent accuracy, reliability, thereby making it a highly accessible choice for diverse universal users and ecological industries or environments.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Concurrent Validity and Reliability of the XLNTbrain Balance Test with the Balance Error Scoring System
    Santo, Ashley
    Brown, Danielle
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 579 - 579
  • [32] Concurrent validity of artificial intelligence-based markerless motion capture for over-ground gait analysis: A study of spatiotemporal parameters
    Ripic, Zachary
    Signorile, Joseph F.
    Kuenze, Christopher
    Eltoukhy, Moataz
    JOURNAL OF BIOMECHANICS, 2022, 143
  • [33] The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults
    Romero Morales, Carlos
    Calvo Lobo, Cesar
    Rodriguez Sanz, David
    Sanz Corbalan, Irene
    Ruiz Ruiz, Beatriz
    Lopez Lopez, Daniel
    PEERJ, 2017, 5
  • [34] Test-retest Reliability And Concurrent Validity Of An In-shoe Pressure System During Two Landing Maneuvers
    Alanazi, Ahmad D.
    Mitchell, Katy
    Roddey, Toni
    Alenazi, Aqeel
    Ortiz, Alexis
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 936 - 936
  • [35] Validity and reliability of trunk and lower-limb kinematics during squatting, hopping, jumping and side-stepping using OpenCap markerless motion capture application
    Lima, Yuri Lopes
    Collings, Tyler
    Hall, Michelle
    Bourne, Matthew N.
    Diamond, Laura E.
    JOURNAL OF SPORTS SCIENCES, 2024, 42 (19) : 1847 - 1858
  • [36] Dual Kinect v2 system can capture lower limb kinematics reasonably well in a clinical setting: concurrent validity of a dual camera markerless motion capture system in professional football players
    Kotsifaki, Argyro
    Whiteley, Rodney
    Hansen, Clint
    BMJ OPEN SPORT & EXERCISE MEDICINE, 2018, 4 (01):
  • [37] Validity and reliability of the WIMU® system to measure barbell velocity during the half-squat exercise
    Garcia-Pinillos, Felipe
    Latorre-Roman, Pedro A.
    Valdivieso-Ruano, Fernando
    Balsalobre-Fernandez, Carlos
    Parraga-Montilla, Juan A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2019, 233 (03) : 408 - 415
  • [38] Verification of reliability and validity of motion analysis systems during bilateral squat using human pose tracking algorithm
    Ota, Megumi
    Tateuchi, Hiroshige
    Hashiguchi, Takaya
    Kato, Takehiro
    Ogino, Yasuhiro
    Yamagata, Momoko
    Ichihashi, Noriaki
    GAIT & POSTURE, 2020, 80 : 62 - 67
  • [39] Reliability and validity of the medial standing overhead arm reach (SOAR) test as a measure of functional hip adduction motion
    Grimes, Jason
    Wager, Justin
    Dizinno, Casey
    Fogarty, Thomas
    Hund, Eric
    Rooney, Brendan
    Roy, Taylor
    Goldfarb, Jon
    Bauer, Paul
    CLINICAL REHABILITATION, 2024, 38 (07) : 955 - 964
  • [40] Measurement of the total body center of gravity during sit-to-stand motion using a markerless motion capture system
    Tanaka, Ryo
    Ishii, Yoshiki
    Yamasaki, Takahiro
    Kawanishi, Hiromichi
    MEDICAL ENGINEERING & PHYSICS, 2019, 66 : 91 - 95