Prompt fission neutron uranium logging (II): dead-time effect of the neutron time spectrum

被引:0
|
作者
Zhang, Yan [1 ,2 ]
Liu, Chi [1 ]
Liu, Shi-Liang [1 ]
Zhang, Hao-Ran [1 ]
Wang, Hai-Tao [1 ]
Qu, Jin-Hui [1 ]
Hu, Wen-Xing [1 ]
Wang, Ren-Bo [1 ]
Tang, Bin [1 ]
机构
[1] East China Univ Technol, Natl Key Lab Uranium Resources Explorat Min & Nucl, Nanchang 330013, Peoples R China
[2] East China Univ Technol, Fundamental Sci Radioact Geol & Explorat Technol L, Nanchang 330013, Peoples R China
基金
中国国家自然科学基金;
关键词
PFNUL; Neutron time spectrum; Dead time; Pulsed source; Correction method; DETECTORS;
D O I
10.1007/s41365-024-01615-x
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The acquisition of neutron time spectrum data plays a pivotal role in the precise quantification of uranium via prompt fission neutron uranium logging (PFNUL). However, the impact of the detector dead-time effect remains paramount in the accurate acquisition of the neutron time spectrum. Therefore, it is imperative for neutron logging instruments to establish a dead-time correction method that is not only uncomplicated but also practical and caters to various logging sites. This study has formulated an innovative equation for determining dead time and introduced a dead-time correction method for the neutron time spectrum, called the "dual flux method." Using this approach, a logging instrument captures two neutron time spectra under disparate neutron fluxes. By carefully selecting specific "windows" on the neutron time spectrum, the dead time can be accurately ascertained. To substantiate its efficacy and discern the influencing factors, experiments were conducted utilizing a deuterium-tritium (D-T) neutron source, a Helium-3 (3\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>{3}$$\end{document}He) detector, and polyethylene shielding to collate and analyze the neutron time spectrum under varying neutron fluxes (at high voltages). The findings underscore that the "height" and "spacing" of the two windows are the most pivotal influencing factors. Notably, the "height" (fd\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${f}_{\text{d}}$$\end{document}) should surpass 2, and the "spacing" twd\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${t}_{\text{wd}}$$\end{document} should exceed 200 mu\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu$$\end{document}s. The dead time of the 3\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>{3}$$\end{document}He detector determined in the experiment was 7.35 mu\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu$$\end{document}s. After the dead-time correction, the deviation of the decay coefficients from the theoretical values for the neutron time spectrum under varying neutron fluxes decreased from 12.4% to within 5%. Similarly, for the PFNUL instrument, the deviation in the decay coefficients decreased from 22.94 to 0.49% after correcting for the dead-time effect. These results demonstrate the exceptional efficacy of the proposed method in ensuring precise uranium quantification. The dual flux method was experimentally validated as a universal approach applicable to pulsed neutron logging instruments and holds immense significance for uranium exploration.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] ANALYSIS OF NEUTRON MULTIPLICITY MEASUREMENTS WITH ALLOWANCE FOR DEAD-TIME LOSSES BETWEEN TIME-CORRELATED DETECTIONS
    VINCENT, CH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (1-2): : 281 - 296
  • [32] NEUTRON LIFETIME, FISSION TIME AND GENERATION TIME
    HAYASHI, M
    NUCLEAR SCIENCE AND ENGINEERING, 1995, 121 (03) : 492 - 492
  • [33] THE EFFECT OF SCATTERING IN FISSION NEUTRON-SPECTRUM MEASUREMENTS BY THE TIME-OF-FLIGHT TECHNIQUE
    BLINOV, MV
    VITENKO, VA
    DUSHIN, VN
    YUREVICH, VI
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 198 (2-3): : 455 - 460
  • [34] Study on the Correction Method for the Dead-Time Effects of Neutron Detectors Due to Pulsed Radiation
    Guo, Siming
    Wu, Jinjie
    Ma, Zhongjian
    Li, Guanjia
    Wang, Qingbin
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 72 (04) : 485 - 491
  • [35] Paralyzable and non-paralyzable dead-time corrections for the neutron detectors of the kuca facility driven by external neutron sources
    Talamo, Alberto
    Gohar, Yousry
    Yamanaka, Masao
    Pyeon, Cheol Ho
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2020, 57 (02) : 157 - 168
  • [36] Study on the Correction Method for the Dead-Time Effects of Neutron Detectors Due to Pulsed Radiation
    Siming Guo
    Jinjie Wu
    Zhongjian Ma
    Guanjia Li
    Qingbin Wang
    Journal of the Korean Physical Society, 2018, 72 : 485 - 491
  • [38] Experimental Study of the influence of PVC casing thickness and well fluid density on prompt fission neutron uranium logging and its corrections
    Zhou, Pengfei
    Tang, Bin
    JOURNAL OF INSTRUMENTATION, 2023, 18 (10)
  • [39] Evaluation and Uncertainty Quantification of Prompt Fission Neutron Spectra of Uranium and Plutonium Isotopes
    Rising, M. E.
    Talou, P.
    Kawano, T.
    Prinja, A. K.
    NUCLEAR SCIENCE AND ENGINEERING, 2013, 175 (01) : 81 - 93
  • [40] A novel method to measure prompt fission neutron spectrum based on fission γ tagging technique
    He Tie
    Xiao Jun
    An Li
    Yang Jian
    Zheng Pu
    ACTA PHYSICA SINICA, 2018, 67 (21)