Reliability, validity, and diagnostic accuracy of the apathy evaluation scale in chronic stroke survivors

被引:0
|
作者
Jamali, Akram [1 ,2 ,3 ,4 ]
Baluchnejadmojarad, Tourandokht [5 ]
Jazaeri, Seyede Zohreh [1 ,2 ,3 ,4 ]
Abedi, Shiva [6 ]
Mehdizadeh, Hajar
Sharabiani, Parvaneh Taghavi Azar [7 ]
Taghizadeh, Ghorban [8 ,9 ]
机构
[1] Iran Univ Med Sci, Fac Adv Technol Med, Dept Neurosci, Tehran, Iran
[2] Iran Univ Med Sci, Cellular & Mol Res Ctr, Tehran, Iran
[3] Iran Univ Med Sci, Student Res Comm, Tehran, Iran
[4] Inst Cognit Sci Studies, Brain & Cognit Clin, Tehran, Iran
[5] Iran Univ Med Sci, Sch Med, Dept Physiol, Tehran, Iran
[6] Univ Social Welf & Rehabil Sci, Dept Occupat Therapy, Tehran, Iran
[7] Iran Univ Med Sci, Shafa Yahyaeian Hosp, Master Sci Occupat Therapy, Tehran, Iran
[8] Iran Univ Med Sci, Geriatr Mental Hlth Res Ctr, Sch Rehabil Sci, Dept Occupat Therapy, Tehran, Iran
[9] Iran Univ Med Sci IUMS, Rehabil Res Ctr, Sch Rehabil Sci, Dept Occupat Therapy, Tehran, Iran
关键词
Apathy; Stroke; AES; Psychometric properties; MODIFIED RANKIN SCALE; PSYCHOMETRIC PROPERTIES; DEPRESSION; VERSION; INDEX;
D O I
10.1186/s12888-025-06626-5
中图分类号
R749 [精神病学];
学科分类号
100205 ;
摘要
Background We aimed to determine the psychometric properties of the Apathy Evaluation Scale (AES) in chronic stroke survivors. Methods In this study, 112 non-cognitive impairment stroke survivors participated. Acceptability, inter-rater, and test-retest reliability of the three Persian versions of AES (clinician, informant, and self-rated) were evaluated. The correlation of three AES versions with the Hospital Anxiety and Depression Scale (HADS), Modified Rankin Scale (mRS), and Barthel Index (BI) was evaluated. To assess the diagnostic accuracy of the three AES versions, stroke survivors were classified as apathetic (n = 43) and non-apathetic (n = 69) groups using the 'diagnostic criteria of apathy'. Results The floor and ceiling effect, skewness, and kurtosis were within acceptable range for three AES versions. Internal consistency (alpha = 0.88-0.91) and test-retest and inter-rater reliability (ICC2,1 >0.90) were acceptable for all AES versions. Standard Error of Measurement and Minimal Detectable Change values for test-retest and/or inter-rater reliability ranged 1.6-2.5 and 4.42-6.93 for three versions of AES, respectively. Significant moderate to high correlation (r or p = -0.34-0.69) was found between three AES versions and HADS-D, HADS-A, BI, and mRS. The cut-off point > 34 (sensitivity = 87.5%, specificity = 72.22%, and AUC = 0.80) was derived for discriminating apathetic from non-apathetic stroke survivors based on the AES- self-rated total score. Conclusion All three AES versions are reliable and valid screening tools to evaluate and characterize apathy in stroke survivors. The AES-self-rated had good discriminative validity for discriminating apathetic from non-apathetic subjects in non-cognitive impairment stroke survivors.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Systematic review: Validity, reliability, and diagnostic accuracy of the electrogustometer
    Blijleven, Esther E.
    Fuchten, Denise
    Dullaart, Max J.
    Stokroos, Robert J.
    Thomeer, Henricus G. X. M.
    Wegner, Inge
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2023, 8 (04): : 1068 - 1079
  • [22] Validity and Reliability of the Videoconference-Based Berg Balance Scale in Stroke Survivors: The Tele-Berg Balance Scale
    da Costa, Aline Barbosa
    Freire, Bruno
    da Silva, Tayara Gaspar
    Michaelsen, Stella Maris
    JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2025, 49 (02): : 65 - 73
  • [23] Validation of the self-rated Dimensional Apathy Scale in community stroke survivors
    Myhre, Pernille
    Radakovic, Ratko
    Ford, Catherine
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2022, 434
  • [24] Validity and reliability of selective control of upper extremity scale (SCUES) in patients with chronic stroke
    Sonmez, Didem Boz
    Giray, Esra
    Atici, Arzu
    Illeez, Ozge Gulsum
    Akpinar, Pinar
    Ozkan, Feyza Unlu
    Aktas, Ilknur
    DISABILITY AND REHABILITATION, 2024, 46 (20) : 4813 - 4824
  • [25] Reliability and validity of a Chinese version of the Stigma Scale for Chronic Illness (SSCI) in patients with stroke
    Lu, Qi
    Deng, Cuiyu
    Fu, Li
    Wu, Rui
    Chang, Lianxia
    Qi, Huaying
    Wang, Kuijie
    Jiang, Lihong
    Yang, Xuan
    Wang, Yulu
    Li, Liya
    Zhao, Yue
    TOPICS IN STROKE REHABILITATION, 2019, 26 (04) : 312 - 317
  • [26] Validity and reliability of retrospective scoring of the NIH stroke scale
    Williams, LS
    Yilmaz, EY
    Lopez-Yunez, AM
    STROKE, 2000, 31 (01) : 333 - 333
  • [27] FRAIL scale: Predictive validity and diagnostic test accuracy
    Thompson, Mark Q.
    Theou, Olga
    Tucker, Graeme R.
    Adams, Robert J.
    Visvanathan, Renuka
    AUSTRALASIAN JOURNAL ON AGEING, 2020, 39 (04) : E529 - E536
  • [28] Concerns for the Reliability and Validity of the National Stroke Project Stroke Severity Scale
    El Husseini, Nada
    Shea, Kenneth J.
    Goldstein, Larry B.
    CEREBROVASCULAR DISEASES, 2011, 32 (05) : 426 - 430
  • [29] Predictive Validity, Diagnostic Accuracy and Test-Retest Reliability of the Strength of Urges to Drink (SUTD) Scale
    Beard, Emma
    Brown, Jamie
    West, Robert
    Drummond, Colin
    Kaner, Eileen
    Michie, Susan
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (19)
  • [30] Assessing reliability and validity of the Chinese version of the stroke scale: Scale development
    Sun, Tzu-Kuan
    Chiu, Su-Chen
    Yeh, Shu-Hui
    Chang, Ku-Chou
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2006, 43 (04) : 457 - 463