Automatic identification of coronary stent in coronary calcium scoring CT using deep learning

被引:0
|
作者
Ahn, Yura [1 ,2 ]
Jeong, Gyu-Jun [1 ,2 ]
Lee, Dabee [3 ]
Kim, Cherry [4 ]
Lee, June-Goo [5 ]
Yang, Dong Hyun [1 ,2 ,6 ]
机构
[1] Univ Ulsan, Dept Radiol, Asan Med Ctr, Coll Med, 88 Olymp ro,43 gil, Seoul 05505, South Korea
[2] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Coll Med, 88 Olymp ro,43 gil, Seoul 05505, South Korea
[3] Dankook Univ Hosp, Dept Radiol, Cheonan Si, South Korea
[4] Korea Univ, Ansan Hosp, Dept Radiol, Ansan, South Korea
[5] Univ Ulsan, Asan Med Ctr, Dept Convergence Med, Coll Med, Seoul, South Korea
[6] Ctr Precis Med Platform Based Smart Hemo Dynam Ind, Seoul, South Korea
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
基金
新加坡国家研究基金会;
关键词
Coronary artery calcium score; Computed tomography; Coronary stent; Artificial intelligence; Accuracy; COMPUTED-TOMOGRAPHY; PLAQUE;
D O I
10.1038/s41598-024-76092-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Coronary artery calcium (CAC) scoring CT is a useful tool for screening coronary artery disease and for cardiovascular risk stratification. However, its efficacy in patients with coronary stents, who had pre-existing coronary artery disease, remains uncertain. Historically, CAC CT scans of these patients have been manually excluded from the CAC scoring process, even though most of the CAC scoring process is now fully automated. Therefore, we hypothesized that automating the filtering of patients with coronary stents using artificial intelligence could streamline the entire CAC workflow, eliminating the need for manual intervention. Consequently, we aimed to develop and evaluate a deep learning-based coronary stent filtering algorithm (StentFilter) in CAC scoring CT scans using a multicenter CAC dataset. We developed StentFilter comprising two main processes: stent identification and false-positive reduction. Development utilized 108 non-enhanced echocardiography-gated CAC scans (including 74 with manually labeled stents), and for false positive reduction, 2063 CAC scans with significant coronary calcium (average Agatston score: 523.8) but no stents were utilized. StentFilter's performance was evaluated on two independent internal test sets (Asan cohort- and 2; n = 355 and 396; one without coronary stents) and two external test sets from different institutions (n = 105 and 62), each with manually labeled stents. We calculated the per-patient sensitivity, specificity, and false-positive rate of StentFilter. StentFilter demonstrated a high overall per-patient sensitivity of 98.8% (511/517 cases with stents) and a false-positive rate of 0.022 (20/918). Notably, the false-positive ratio was significantly lower in the dataset containing stents (Asan cohort-1; 0.008 [3/355]) compared with the dataset without stents (Asan cohort-2; 0.043 [17/396], p = 0.008). All false-positive identifications were attributed to dense coronary calcifications, with no false positives identified in extracoronary locations. The automated StentFilter accurately distinguished coronary stents from pre-existing coronary calcifications. This approach holds potential as a filter within a fully automated CAC scoring workflow, streamlining the process efficiently.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Technical feasibility and validation of a coronary artery calcium scoring system using CT coronary angiography images
    Christopher W. Pavitt
    Katie Harron
    Alistair C. Lindsay
    Sayeh Zielke
    Robin Ray
    Daniel Gordon
    Michael B. Rubens
    Simon P. Padley
    Edward D. Nicol
    European Radiology, 2016, 26 : 1493 - 1502
  • [32] Technical feasibility and validation of a coronary artery calcium scoring system using CT coronary angiography images
    Pavitt, Christopher W.
    Harron, Katie
    Lindsay, Alistair C.
    Zielke, Sayeh
    Ray, Robin
    Gordon, Daniel
    Rubens, Michael B.
    Padley, Simon P.
    Nicol, Edward D.
    EUROPEAN RADIOLOGY, 2016, 26 (05) : 1493 - 1502
  • [33] Interplatform Reproducibility of CT Coronary Calcium Scoring Software
    Weininger, Markus
    Ritz, Kristin S.
    Schoepf, U. Joseph
    Flohr, Thomas G.
    Vliegenthart, Rozemarijn
    Costello, Philip
    Hahn, Dietbert
    Beissert, Matthias
    RADIOLOGY, 2012, 265 (01) : 70 - 77
  • [34] Coronary Calcium Scoring without Dedicated Noncontrast CT
    Goldfarb, James W.
    Cao, J. Jane
    RADIOLOGY, 2022, 302 (02) : 317 - 318
  • [35] CORONARY ARTERY CALCIUM SCORING ON ROUTINE PET/CT
    Ng, Wesley
    Lee, Sze Ting
    Welch, Jessica
    Desmond, Sherylene
    Saleem, Schimmel
    Pathmaraj, Kunthi
    Wright, Samuel
    Scott, Andrew M.
    Berlangieri, Salvatore
    Rowe, Christopher
    INTERNAL MEDICINE JOURNAL, 2013, 43 : 1 - 1
  • [36] Vessel Specific Coronary Artery Calcium Scoring: An Automatic System
    Shahzad, Rahil
    van Walsum, Theo
    Schaap, Michiel
    Rossi, Alexia
    Klein, Stefan
    Weustink, Annick C.
    de Feyter, Pim J.
    van Vliet, Lucas J.
    Niessen, Wiro J.
    ACADEMIC RADIOLOGY, 2013, 20 (01) : 1 - 9
  • [37] Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease
    Marc Dewey
    Bernd Hamm
    European Radiology, 2007, 17 : 1301 - 1309
  • [38] CORONARY CALCIUM SCORING FROM CONTRAST CORONARY CT ANGIOGRAPHY USING AN AUTOMATED STANDARDIZED METHOD: A MULTICENTER STUDY
    Schuhbaeck, Annika
    Otaki, Yuka
    Achenbach, Stephan
    Schneider, Christian
    Hecker, Franziska
    Rixe, Johannes
    Slomka, Piotr
    Min, James
    Berman, Daniel
    Dey, Damini
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E914 - E914
  • [39] Coronary risk assessment using traditional risk factors with CT coronary artery calcium scoring in clinical practice
    Kerut, Edmund Kenneth
    Hall, Michael E.
    Turner, Michael C.
    McMullan, Michael R.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (08): : 1216 - 1222
  • [40] Influence of computed tomography slice thickness on deep learning-based, automatic coronary artery calcium scoring software performance
    Kim, Suh Young
    Suh, Young Joo
    Lee, Hye-Jeong
    Kim, Hwiyoung
    Seo, Hyungi
    Park, Hee Jun
    Yang, Dong Hyun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (07) : 4257 - +