Detection of IDH mutation in glioma by desorption electrospray ionization (DESI) tandem mass spectrometry

被引:0
|
作者
Shahi, Mahdiyeh [1 ]
Pringle, Steven [2 ]
Morris, Michael [2 ]
Garcia, Diogo Moniz [3 ]
Quinones-Hinojosa, Alfredo [3 ]
Cooks, R. Graham [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Waters Corp, Stamford Ave, Wilmslow SK9 4AX, England
[3] Mayo Clin, Dept Neurosurg, Jacksonville, FL 32224 USA
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Multiple reaction monitoring (MRM); 2-hydroxyglutarate; Oncometabolite; Molecular diagnostics; Brain cancer; Ambient ionization; CLASSIFICATION; TUMORS;
D O I
10.1038/s41598-024-77044-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Desorption electrospray ionization (DESI) tandem mass spectrometry (MS) is used to assess mutation status of isocitrate dehydrogenase (IDH) in human gliomas. Due to the diffuse nature of gliomas, total gross resection is not normally achieved during surgery, leading to tumor recurrence. The mutation status of IDH has clinical significance due to better prognosis in IDH-mutant patients. The mutant IDH converts alpha-ketoglutaric acid (alpha-KG) into 2-hydroxyglutarate (2HG), which accumulates abnormally in cells. Immunohistochemical staining (IHC) and genetic testing, the gold standards, are incompatible with intraoperative applications but DESI tandem mass spectrometry (MS/MS) can be used to assess the mutation status of IDH enzyme from tissue intraoperatively. Here, on off-line evaluation is made of the performance of two different types of mass spectrometers in characterization of IDH mutation status. The intensity of 2HG is measured against glutamate (Glu), an intrinsic reference molecule, in both tandem MS measurements. In both cases using DESI clear separation between IDH-mutant (mut) and IDH-wildtype (wt) samples (p < 0.0001) is observed, despite the short analysis time. Due to the higher detection sensitivity, multiple reaction monitoring experiments using a triple quadrupole show slightly better performance compared to product ion MS/MS performed on a simple linear ion trap. Both DESI-MS platforms are capable of providing information on IDH mutation status, which might in future be used at the time of surgery to support decision-making on resection regions, especially at tumor margins.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Nanospray Desorption Electrospray Ionization Mass Spectrometry Imaging (nano-DESI MSI): A Tutorial Review
    Iqfath, Mushfeqa
    Wali, Syeda Nazifa
    Amer, Sara
    Hernly, Emerson
    Laskin, Julia
    ACS MEASUREMENT SCIENCE AU, 2024, 4 (05): : 475 - 487
  • [22] Imaging of triglycerides in tissues using nanospray desorption electrospray ionization (Nano-DESI) mass spectrometry
    Unsihuay, Daisy
    Qiu, Jiamin
    Swaroop, Sneha
    Nagornov, Konstantin O.
    Kozhinov, Anton N.
    Tsybin, Yury O.
    Kuang, Shihuan
    Laskin, Julia
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 448
  • [23] Reactive desorption electrospray ionization mass spectrometry (DESI-MS) of natural products of a marine alga
    Leonard Nyadong
    Edward G. Hohenstein
    Asiri Galhena
    Amy L. Lane
    Julia Kubanek
    C. David Sherrill
    Facundo M. Fernández
    Analytical and Bioanalytical Chemistry, 2009, 394 : 245 - 254
  • [24] Direct Analysis of Liquid Samples by Desorption Electrospray Ionization-Mass Spectrometry (DESI-MS)
    Miao, Zhixin
    Chen, Hao
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (01) : 10 - 19
  • [25] Reactive desorption electrospray ionization mass spectrometry (DESI-MS) of natural products of a marine alga
    Nyadong, Leonard
    Hohenstein, Edward G.
    Galhena, Asiri
    Lane, Amy L.
    Kubanek, Julia
    Sherrill, C. David
    Fernandez, Facundo M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (01) : 245 - 254
  • [26] Understanding the Molecular Signatures in Leaves and Flowers by Desorption Electrospray Ionization Mass Spectrometry (DESI MS) Imaging
    Hemalatha, R. G.
    Pradeep, T.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (31) : 7477 - 7487
  • [27] Direct Analysis of Liquid Samples by Desorption Electrospray Ionization-Mass Spectrometry (DESI-MS)
    Miao, Zhixin
    Chen, Hao
    Journal of the American Society for Mass Spectrometry, 2009, 20 (01): : 10 - 19
  • [28] An atmospheric pressure ionization source based on desorption electrospray ionization technology (DESI) for ion cyclotron resonance mass spectrometry
    Agapov, A. Yu.
    Levitsky, L. I.
    Dashtiev, N. Z.
    Gorshkov, M. V.
    Tarasova, I. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (14) : 1376 - 1384
  • [29] An atmospheric pressure ionization source based on desorption electrospray ionization technology (DESI) for ion cyclotron resonance mass spectrometry
    A. Yu. Agapov
    L. I. Levitsky
    N. Z. Dashtiev
    M. V. Gorshkov
    I. A. Tarasova
    Journal of Analytical Chemistry, 2011, 66 : 1376 - 1384
  • [30] Electrospray ionization tandem mass spectrometry of chaetoglobosins
    Xu, Guo-Bo
    Li, Li-Mei
    Fang, Dong-Mei
    Li, Guo-You
    Zhang, Guo-Lin
    Wu, Zhi-Jun
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (18) : 2115 - 2122