Detection of IDH mutation in glioma by desorption electrospray ionization (DESI) tandem mass spectrometry

被引:0
|
作者
Shahi, Mahdiyeh [1 ]
Pringle, Steven [2 ]
Morris, Michael [2 ]
Garcia, Diogo Moniz [3 ]
Quinones-Hinojosa, Alfredo [3 ]
Cooks, R. Graham [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Waters Corp, Stamford Ave, Wilmslow SK9 4AX, England
[3] Mayo Clin, Dept Neurosurg, Jacksonville, FL 32224 USA
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Multiple reaction monitoring (MRM); 2-hydroxyglutarate; Oncometabolite; Molecular diagnostics; Brain cancer; Ambient ionization; CLASSIFICATION; TUMORS;
D O I
10.1038/s41598-024-77044-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Desorption electrospray ionization (DESI) tandem mass spectrometry (MS) is used to assess mutation status of isocitrate dehydrogenase (IDH) in human gliomas. Due to the diffuse nature of gliomas, total gross resection is not normally achieved during surgery, leading to tumor recurrence. The mutation status of IDH has clinical significance due to better prognosis in IDH-mutant patients. The mutant IDH converts alpha-ketoglutaric acid (alpha-KG) into 2-hydroxyglutarate (2HG), which accumulates abnormally in cells. Immunohistochemical staining (IHC) and genetic testing, the gold standards, are incompatible with intraoperative applications but DESI tandem mass spectrometry (MS/MS) can be used to assess the mutation status of IDH enzyme from tissue intraoperatively. Here, on off-line evaluation is made of the performance of two different types of mass spectrometers in characterization of IDH mutation status. The intensity of 2HG is measured against glutamate (Glu), an intrinsic reference molecule, in both tandem MS measurements. In both cases using DESI clear separation between IDH-mutant (mut) and IDH-wildtype (wt) samples (p < 0.0001) is observed, despite the short analysis time. Due to the higher detection sensitivity, multiple reaction monitoring experiments using a triple quadrupole show slightly better performance compared to product ion MS/MS performed on a simple linear ion trap. Both DESI-MS platforms are capable of providing information on IDH mutation status, which might in future be used at the time of surgery to support decision-making on resection regions, especially at tumor margins.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Trace detection of inorganic oxidants using desorption electrospray ionization (DESI) mass spectrometry
    Sokol, Ewa
    Jackson, Ayanna U.
    Cooks, R. Graham
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2011, 9 (05): : 790 - 797
  • [2] Desorption electrospray ionization (DESI) mass Spectrometry and tandem mass spectrometry (MS/MS) of phospholipids and sphingolipids: Ionization, adduct formation, and fragmentation
    Manicke, Nicholas E.
    Wiseman, Justin M.
    Ifa, Demian R.
    Cooks, R. Graham
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (04) : 531 - 543
  • [3] Coupling of liquid chromatography with mass spectrometry by desorption electrospray ionization (DESI)
    Zhang, Yun
    Yuan, Zongqian
    Dewald, Howard D.
    Chen, Hao
    CHEMICAL COMMUNICATIONS, 2011, 47 (14) : 4171 - 4173
  • [4] A Combined Desorption Ionization by Charge Exchange (DICE) and Desorption Electrospray Ionization (DESI) Source for Mass Spectrometry
    Chan, Chang-Ching
    Bolgar, Mark S.
    Miller, Scott A.
    Attygalle, Athula B.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (01) : 173 - 178
  • [5] Forensic analysis of inks by imaging desorption electrospray ionization (DESI) mass spectrometry
    Ifa, D. R.
    Gumaelius, L. M.
    Eberlin, L. S.
    Manicke, N. E.
    Cooks, R. G.
    ANALYST, 2007, 132 (05) : 461 - 467
  • [6] Desorption Electrospray Ionization (DESI) of Digital Polymers: Direct Tandem Mass Spectrometry Decoding and Imaging from Materials Surfaces
    Amalian, Jean-Arthur
    Mondal, Tathagata
    Konishcheva, Evgeniia
    Cavallo, Gianni
    Petit, Benoit Eric
    Lutz, Jean-Francois
    Charles, Laurence
    ADVANCED MATERIALS TECHNOLOGIES, 2021, 6 (04)
  • [7] Desorption electrospray ionization (DESI)
    不详
    MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S455 - S455
  • [8] Tissue imaging at atmospheric pressure using desorption electrospray ionization (DESI) mass spectrometry
    Wiseman, Justin M.
    Ifa, Demian R.
    Song, Qingyu
    Cooks, R. Graham
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (43) : 7188 - 7192
  • [9] Desorption electrospray ionization (DESI) with atmospheric pressure ion mobility spectrometry for drug detection
    Roscioli, Kristyn M.
    Tufariello, Jessica A.
    Zhang, Xing
    Li, Shelly X.
    Goetz, Gilles H.
    Cheng, Guilong
    Siems, William F.
    Hill, Herbert H., Jr.
    ANALYST, 2014, 139 (07) : 1740 - 1750
  • [10] Desorption Electrospray Ionization Tandem Mass Spectrometry for Detection of 24 Carcinogenic Aromatic Amines in Textiles
    Yang, Shuiping
    Han, Jing
    Huan, Yanfu
    Cui, Yanjuan
    Zhang, Xie
    Chen, Huanwen
    Gu, Haiwei
    ANALYTICAL CHEMISTRY, 2009, 81 (15) : 6070 - 6079