Effect of instant ear domes on real-ear gain

被引:0
|
作者
Attia, Salma Samy [1 ]
Kozou, Hesham [1 ]
Elmoazen, Doaa [1 ]
机构
[1] Alexandria Univ, Alexandria, Egypt
来源
EGYPTIAN JOURNAL OF OTOLARYNGOLOGY | 2025年 / 41卷 / 01期
关键词
Instant ear domes; Insertion loss; Vent effect; Occlusion effect; RIC; OCCLUSION; RECEIVER; VENT;
D O I
10.1186/s43163-025-00767-w
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
PurposeAs instant ear domes are the most commonly used fittings for RIC hearing aids and are available in standard sizes and shapes which may include vents, this study was designed to assess the acoustics of these different types of domes by estimating the insertion loss and vent effect of each using real-ear measurements to make the right fitting choice.MethodsThe study included 30 normal hearing individuals. REM procedures specifically insertion loss and vent effect measurements were obtained using Affinity 2.0 Interacoustics while using five types of domes: open, tulip, Bass 1 vent, Bass 2 vent, and double dome. The subjective occlusion rating of each dome was assessed as well.ResultsThe instant ear domes are arranged from least occluding (lowest insertion loss, highest vent effect, lowest subjective rating score) to most occluding (highest insertion loss, lowest vent effect, highest subjective rating score) as follows: open dome, tulip dome, and bass group which showed no significant difference between 1 and 2 vents and lastly double dome. Results showed high variability.ConclusionsInstant domes with larger vent whether a single large diameter or sum of several diameters vent have lowest insertion loss, highest vent effect and lowest score in subjective occlusion ratings, and vice versa. Individualized real-ear measurement should be considered for best fitting outcome.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The influence of RECD transducer when deriving real-ear sound pressure level
    Munro, Kevin J.
    Millward, Kerri E.
    EAR AND HEARING, 2006, 27 (04): : 409 - 423
  • [32] Extended bandwidth real-ear measurement accuracy and repeatability to 10kHz
    Vaisberg, Jonathan M.
    Macpherson, Ewan A.
    Scollie, Susan D.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2016, 55 (10) : 580 - 586
  • [33] Differences in Sensation Level between the Widex SoundTracker and Two Real-Ear Analyzers
    Oeding, Kristi
    Valente, Michael
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2013, 24 (08) : 660 - 670
  • [34] BODY-BAFFLE AND REAL-EAR EFFECTS IN SELECTION OF HEARING AIDS FOR DEAF CHILDREN
    ERBER, NP
    JOURNAL OF SPEECH AND HEARING DISORDERS, 1973, 38 (02): : 224 - 231
  • [35] Real ear unaided gain and its relation with the equivalent volume of the external and middle ear
    Bastos, Barbara Guimaraes
    Ferrari, Deborah Viviane
    Blasc, Wanderleia Quinhoneiro
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2012, 16 (03) : 365 - 370
  • [36] Probe-tube microphone measures in patients with open-mastoid surgery: Real-ear-to-coupler differences and real-ear unaided responses
    Liu, TC
    Lin, KN
    AUDIOLOGY AND NEURO-OTOLOGY, 2000, 5 (02) : 59 - 63
  • [37] Reliability of real ear insertion gain in behind-the-ear hearing aids with different coupling systems to the ear canal
    Jespersen, Charlotte Thunberg
    Moller, Kimi Nina
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2013, 52 (03) : 169 - 176
  • [38] COMPARABLE COUPLER AND REAL-EAR MEASUREMENTS ON SUPRAAURAL-AND INSERT-TYPE EARPHONES
    BRYANT, HW
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1972, 52 (06): : 1599 - 1606
  • [39] REAL-EAR ATTENUATION CHARACTERISTICS OF SELECTED NOISE-EXCLUDING AUDIOMETRIC RECEIVER ENCLOSURES
    COPELAND, AB
    MOWRY, HJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1971, 49 (06): : 1757 - &
  • [40] Distribution of standing-wave errors in real-ear sound-level measurements
    Richmond, Susan A.
    Kopun, Judy G.
    Neely, Stephen T.
    Tan, Hongyang
    Gorga, Michael P.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (05): : 3134 - 3140