Expanding the volume on 4D flow CMR Editorial for "Robustness of 4D flow MRI derived aortic wall shear stress and pulse wave velocity across different protocols in healthy controls and in patients with bicuspid aortic valve"

被引:0
|
作者
Fischer, Kady [1 ]
Bastiaansen, Jessica A. M. [2 ,3 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Anaesthesiol & Pain Med, Inselspital, Freiburg str 10, CH-3010 Bern, Switzerland
[2] Swiss Inst Translat & Entrepreneurial Med, Translat Imaging Ctr TIC, Bern, Switzerland
[3] Univ Bern, Bern Univ Hosp, Dept Diagnost Intervent & Pediat Radiol DIPR, Bern, Switzerland
来源
关键词
D O I
10.1007/s10554-025-03335-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:181 / 183
页数:3
相关论文
共 50 条
  • [41] Pressure Fields by Flow-Sensitive, 4D, Velocity-Encoded CMR in Patients With Aortic Coarctation
    Riesenkampff, Eugenie
    Fernandes, Joao Filipe
    Meier, Sebastian
    Goubergrits, Leonid
    Kropf, Siegfried
    Schubert, Stephan
    Berger, Felix
    Henneumuth, Anja
    Kuehne, Titus
    JACC-CARDIOVASCULAR IMAGING, 2014, 7 (09) : 920 - 926
  • [42] Thoracic aorta flow by 4D flow CMR is altered in patients presenting partial fusion of two aortic valve leaflets
    Guala, A.
    Galian, L.
    Teixido Tura, G.
    Ruiz Munoz, A.
    Granato, C.
    Valente, F.
    Johnson, K. M.
    Wieben, O.
    Sao Aviles, A.
    Gutierrez, L.
    Gonzalez-Alujas, T.
    Evangelista, A.
    Rodriguez-Palomares, J. F.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 405 - 405
  • [43] 4D Flow Magnetic Resonance Imaging in Bicuspid Aortic Valve Disease Demonstrates Altered Distribution of Aortic Blood Flow Helicity
    Lorenz, R.
    Bock, J.
    Barker, A. J.
    von Knobelsdorff-Brenkenhoff, F.
    Wallis, W.
    Korvink, J. G.
    Bissell, M. M.
    Schulz-Menger, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1542 - 1553
  • [44] Patients with blunt traumatic thoracic aortic injury treated with TEVAR present increased flow dynamics alterations and pulse wave velocity: a 4D flow CMR study
    Guala, A.
    Gil Sala, D.
    Ruiz-Munoz, A.
    Garcia Reyes, M. E.
    Dux-Santoy, L.
    Teixido-Tura, G.
    Tello, C.
    Cinque, A.
    Valente, F.
    Lopez Sainz, A.
    Galian Gay, L.
    Ferreira, I
    Evangelista, A.
    Bellmunt Montoya, S.
    Rodriguez Palomares, J. F.
    EUROPEAN HEART JOURNAL, 2020, 41 : 2351 - 2351
  • [45] Assessing cerebral arterial pulse wave velocity using 4D flow MRI
    Bjornfot, Cecilia
    Garpebring, Anders
    Qvarlander, Sara
    Malm, Jan
    Eklund, Anders
    Wahlin, Anders
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2021, 41 (10): : 2769 - 2777
  • [46] In Vitro Validation of 4D Flow MRI for Local Pulse Wave Velocity Estimation
    Timothy Ruesink
    Rafael Medero
    David Rutkowski
    Alejandro Roldán-Alzate
    Cardiovascular Engineering and Technology, 2018, 9 : 674 - 687
  • [47] In Vitro Validation of 4D Flow MRI for Local Pulse Wave Velocity Estimation
    Ruesink, Timothy
    Medero, Rafael
    Rutkowski, David
    Roldan-Alzate, Alejandro
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) : 674 - 687
  • [48] Reproducibility and inter-observer variability of velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta
    Pim van Ooij
    Alexander L Powell
    Wouter V Potters
    Alex J Barker
    Michael Markl
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [49] Editorial for "Evaluating a Phase-Specific Approach to Aortic Flow: A 4D Flow MRI Study"
    Cebull, Hannah L.
    Oshinski, John N.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) : 1068 - 1069
  • [50] Aortic pulse wave velocity measurements with undersampled 4D flow-sensitive MRI: comparison with 2D and algorithm determination
    Wentland, Andrew L.
    Wieben, Oliver
    Francois, Chris J.
    Boncyk, Christina
    Del Rio, Alejandro Munoz
    Johnson, Kevin M.
    Grist, Thomas M.
    Frydrychowicz, Alex
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) : 853 - 859