Finite element analysis of modified pedicle screw fixation and traditional lumbopelvic fixation for the treatment of sacroiliac joint disruption

被引:0
|
作者
Zhang, Jun [1 ]
Wei, Yan [2 ]
Yin, Weizhong [1 ]
Wang, Jian [1 ]
Liu, Bingli [3 ]
Ao, Rongguang [3 ]
Yu, Baoqing [3 ]
机构
[1] Pudong New Area Peoples Hosp, Dept Orthopaed, Shanghai 201299, Peoples R China
[2] Pudong New Area Peoples Hosp, Dept Surg, Shanghai 201299, Peoples R China
[3] Shanghai Univ TCM, Peoples Hosp 7, Dept Orthopaed, Shanghai 200137, Peoples R China
关键词
Sacroiliac joint disruption; Pedicle screw fixation; Lumbopelvic fixation; Internal fixation; Finite element analysis; FRACTURES; SACRUM; PLATE;
D O I
10.1186/s12891-024-08185-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe modified pedicle screw fixation (PSF) was designed to simulate an integrated framework structure to ameliorate the resistance to vertical and shearing forces of the disrupted sacroiliac complex, and the aim of this study was to compare the biomechanical characteristics of PSF and traditional lumbopelvic fixation (LPF) for the treatment of sacroiliac joint disruption.MethodsThe digital computer simulation model of an intact spine-pelvis-femur complex with main ligaments was built from clinical images. A left sacroiliac joint disruption model was mimicked by removing the concerned ligaments. After model validation, the two fixation models (modified PSF and traditional LPF) were established, and assembled with the disruption model. Under five loading scenarios (compression, flexion, extension, right bending, and left twisting), the finite element simulation was implemented. The maximum von Mises stress (VMS) of internal fixations and pelvises, maximum deformations on the Z-, Y-, X-axes and overall deformation of the sacrum were evaluated and compared.ResultsUnder all loading conditions, the maximum VMS of internal fixations and pelvises in the modified PSF model were lower than those in the traditional LPF model. Under flexion, right bending, and left twisting, the maximum Z-axis deformation of the sacrum for the modified PSF model was smaller than that of the traditional LPF model. For compression, the maximum Y-axis deformation of the sacrum was smaller than that of the traditional LPF model. During various loading modes, the maximum X-axis, and overall deformations of the sacrum for the modified PSF model were smaller than those in the traditional LPF model.ConclusionsCompared with the traditional LPF, the modified PSF shows superior biomechanical stability, with satisfied resistance to vertical and shearing forces, which might be potentially suitable for treating sacroiliac joint disruption.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] A comparative finite element analysis of artificial intervertebral disc replacement and pedicle screw fixation of the lumbar spine
    Biswas, Jayanta Kumar
    Malas, Anindya
    Majumdar, Sourav
    Rana, Masud
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (16) : 1812 - 1820
  • [32] Finite element analysis of anterior lumbar interbody fusion - Threaded cylindrical cage and pedicle screw fixation
    Kim, Young
    SPINE, 2007, 32 (23) : 2558 - 2568
  • [33] Measurement of strain in the rod for lumbar pedicle screw fixation: An experimental and finite element study
    Rana, Masud
    Biswas, Jayanta Kumar
    Roy, Sandipan
    Ghosh, Niloy
    Bhattacharya, Shambo
    Karmakar, Santanu Kumar
    Roychowdhury, Amit
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06)
  • [34] Individualized prediction of pedicle screw fixation strength - an experimentally validated finite element study
    Widmer, Jonas
    Fasser, Marie-Rosa
    Croci, Eleonora
    Spirig, Jose
    Snedeker, Jess
    Farshad, Mazda
    SWISS MEDICAL WEEKLY, 2019, 149 : 26S - 26S
  • [35] Pedicle screw fixation with translaminar facet joint screws for the treatment of thoracolumbar fracture
    殷渠东
    郑祖根
    蔡建平
    Chinese Journal of Traumatology, 2004, (06)
  • [36] Systematic review of sacroiliac joint motion and the effect of screw fixation
    Cardwell, Maxwell C.
    Meinerz, Carolyn M.
    Martin, Jill M.
    Beck, Chad J.
    Wang, Mei
    Schmeling, Gregory J.
    CLINICAL BIOMECHANICS, 2021, 85
  • [37] Accuracy of computer-guided screw fixation of the sacroiliac joint
    Gautier, E
    Bächler, R
    Heini, PF
    Nolte, LP
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (393) : 310 - 317
  • [38] Pedicle screw fixation with translaminar facet joint screws for the treatment of thoracolumbar fracture
    殷渠东
    郑祖根
    蔡建平
    中华创伤杂志(英文版), 2004, (06) : 35 - 38
  • [39] Effect of Physiological Loads on Cortical and Traditional Pedicle Screw Fixation
    Baluch, Daniel A.
    Patel, Alpesh A.
    Lullo, Brett
    Havey, Robert M.
    Voronov, Leonard I.
    Ngoc-Lam Nguyen
    Carandang, Gerard
    Ghanayem, Alexander J.
    Patwardhan, Avinash G.
    SPINE, 2014, 39 (22) : E1297 - E1302
  • [40] Endoscopic Rescue Technique for Iatrogenic Sacroiliac Joint Syndrome Caused by Sextant Percutaneous Pedicle Screw Fixation System
    Nam, Han Ga Wi
    Lim, Kang Taek
    Park, Jin Soo
    Park, Chun-Kun
    Kim, Hyung Suk
    WORLD NEUROSURGERY, 2019, 124 : 345 - 349